8 research outputs found
Restoration of Bile Duct Injury of Donor Livers During Ex Situ Normothermic Machine Perfusion
BACKGROUND: End-ischemic ex situ normothermic machine perfusion (NMP) enables assessment of donor livers prior to transplantation. The objective of this study was to provide support for bile composition as a marker of biliary viability and to investigate whether bile ducts of high-risk human donor livers already undergo repair during NMP.METHODS: Forty-two livers that were initially declined for transplantation were included in our NMP clinical trial. After NMP, livers were either secondary declined (n = 17) or accepted for transplantation (n = 25) based on the chemical composition of bile and perfusate samples. Bile duct biopsies were taken before and after NMP and assessed using an established histological injury severity scoring system and a comprehensive immunohistochemical assessment focusing on peribiliary glands (PBGs), vascular damage, and regeneration.RESULTS: Bile ducts of livers that were transplanted after viability testing during NMP showed better preservation of PBGs, (micro)vasculature, and increased cholangiocyte proliferation, compared with declined livers. Biliary bicarbonate, glucose, and pH were confirmed as accurate biomarkers of bile duct vitality. In addition, we found evidence of PBG-based progenitor cell differentiation toward mature cholangiocytes during NMP.CONCLUSIONS: Favorable bile chemistry during NMP correlates well with better-preserved biliary microvasculature and PBGs, with a preserved capacity for biliary regeneration. During NMP, biliary tree progenitor cells start to differentiate toward mature cholangiocytes, facilitating restoration of the ischemically damaged surface epithelium.</p
Sequential hypothermic and normothermic machine perfusion enables safe transplantation of high-risk donor livers
Ex situ normothermic machine perfusion (NMP) is increasingly used for viability assessment of high-risk donor livers, whereas dual hypothermic oxygenated machine perfusion (DHOPE) reduces ischemia-reperfusion injury. We aimed to resuscitate and test the viability of initially-discarded, high-risk donor livers using sequential DHOPE and NMP with two different oxygen carriers: an artificial hemoglobin-based oxygen carrier (HBOC) or red blood cells (RBC). In a prospective observational cohort study of 54 livers that underwent DHOPE-NMP, the first 18 procedures were performed with a HBOC-based perfusion solution and the subsequent 36 procedures were performed with an RBC-based perfusion solution for the NMP phase. All but one livers were derived from extended criteria donation after circulatory death donors, with a median donor risk index of 2.84 (IQR 2.52–3.11). After functional assessment during NMP, 34 livers (63% utilization), met the viability criteria and were transplanted. One-year graft and patient survival were 94% and 100%, respectively. Post-transplant cholangiopathy occurred in 1 patient (3%). There were no significant differences in utilization rate and post-transplant outcomes between the HBOC and RBC group. Ex situ machine perfusion using sequential DHOPE-NMP for resuscitation and viability assessment of high-risk donor livers results in excellent transplant outcomes, irrespective of the oxygen carrier used.</p
Sequential Hypothermic and Normothermic Machine Perfusion Enables Safe Transplantation of High-risk Donor Livers
Ex situ normothermic machine perfusion (NMP) is increasingly used for viability assessment of high-risk donor livers, whereas dual hypothermic oxygenated machine perfusion (DHOPE) reduces ischemia-reperfusion injury. We aimed to resuscitate and test the viability of initially-discarded, high-risk donor livers using sequential DHOPE and NMP with two different oxygen carriers: an artificial hemoglobin-based oxygen carrier (HBOC) or red blood cells (RBC). In a prospective observational cohort study of 54 livers that underwent DHOPE-NMP, the first 18 procedures were performed with a HBOC-based perfusion solution and the subsequent 36 procedures were performed with an RBC-based perfusion solution for the NMP phase. All but one livers were derived from extended criteria donation after circulatory death donors, with a median donor risk index of 2.84 (IQR 2.52-3.11). After functional assessment during NMP, 34 livers (63% utilization), met the viability criteria and were transplanted. One-year graft and patient survival were 94% and 100%, respectively. Post-transplant cholangiopathy occurred in 1 patient (3%). There were no significant differences in utilization rate and post-transplant outcomes between the HBOC and RBC group. Ex situ machine perfusion using sequential DHOPE-NMP for resuscitation and viability assessment of high-risk donor livers results in excellent transplant outcomes, irrespective of the oxygen carrier used
Sequential hypothermic and normothermic machine perfusion enables safe transplantation of high-risk donor livers
Ex situ normothermic machine perfusion (NMP) is increasingly used for viability assessment of high-risk donor livers, whereas dual hypothermic oxygenated machine perfusion (DHOPE) reduces ischemia-reperfusion injury. We aimed to resuscitate and test the viability of initially-discarded, high-risk donor livers using sequential DHOPE and NMP with two different oxygen carriers: an artificial hemoglobin-based oxygen carrier (HBOC) or red blood cells (RBC). In a prospective observational cohort study of 54 livers that underwent DHOPE-NMP, the first 18 procedures were performed with a HBOC-based perfusion solution and the subsequent 36 procedures were performed with an RBC-based perfusion solution for the NMP phase. All but one livers were derived from extended criteria donation after circulatory death donors, with a median donor risk index of 2.84 (IQR 2.52–3.11). After functional assessment during NMP, 34 livers (63% utilization), met the viability criteria and were transplanted. One-year graft and patient survival were 94% and 100%, respectively. Post-transplant cholangiopathy occurred in 1 patient (3%). There were no significant differences in utilization rate and post-transplant outcomes between the HBOC and RBC group. Ex situ machine perfusion using sequential DHOPE-NMP for resuscitation and viability assessment of high-risk donor livers results in excellent transplant outcomes, irrespective of the oxygen carrier used.</p
First report of successful transplantation of a pediatric donor liver graft after hypothermic machine perfusion
One of the main limiting factors in pediatric liver transplantation is donor availability. For adults, DCD liver grafts are increasingly used to expand the donor pool. To improve outcome after DCD liver transplantation, ex situ machine perfusion is used as an alternative organ preservation strategy, with the supplemental value of providing oxygen to the graft during preservation. We here report the first successful transplantation of a pediatric DCD liver graft after hypothermic oxygenated machine perfusion. The full-size liver graft was derived from a 13-year-old, female DCD donor and was end-ischemic pretreated with dual hypothermic oxygenated machine perfusion. Arterial and portal pressures were set at 18 and 4 mm Hg, slightly lower than protocolized settings for adult livers. During 2 hours of machine perfusion, portal and arterial flows increased from 100 to 210 mL/min and 30 to 63 mL/min, respectively. The pretreated liver graft was implanted in a 16-year-old girl with progressive familial intrahepatic cholestasis type 2. Postoperative AST, ALT, and prothrombin time normalized within a week. The recipient quickly recovered and was discharged from the hospital after 18 days. One year after transplantation, she is in excellent condition with a completely normal liver function and histology. This case is the first report of successful transplantation of a pediatric DCD liver graft after hypothermic oxygenated machine perfusion and illustrates the potential role of ex situ machine perfusion in expanding the donor pool and improving outcome after pediatric liver transplantation