117 research outputs found

    Holographic model for dilepton production in p-p collisions

    Full text link
    We propose a holographic model for dilepton production in proton-proton collisions based on the exchange of vector mesons. The holographic hard wall model is used to describe the dynamics and interactions of vector mesons and baryons. We estimate the parameters lambda, mu, nu that characterize the angular distribution of the produced dileptons in a region of q_T^2 << Q^2, where perturbative QCD presents an effective strong coupling due to large logarithm corrections.Comment: Revision: V4 In this version we modified the dimension of the fermionic operator to match the canonical dimension of a baryonic operator. This modification affected slightly our results with respect to v3. 25 pages, 3 Latex figures + 6 eps figures, 5 tables. To appear in Nucl. Phys.

    Molecular characterization and phylogeny of Shiga toxin–producing Escherichia coli isolates obtained from two Dutch regions using whole genome sequencing

    Get PDF
    AbstractShiga toxin–producing Escherichia coli (STEC) is one of the major causes of human gastrointestinal disease and has been implicated in sporadic cases and outbreaks of diarrhoea, haemorrhagic colitis and haemolytic uremic syndrome worldwide. In this study, we determined the molecular characteristics and phylogenetic relationship of STEC isolates, and their genetic diversity was compared to that of other E. coli populations. Whole genome sequencing was performed on 132 clinical STEC isolates obtained from the faeces of 129 Dutch patients with gastrointestinal complaints. STEC isolates of this study belonged to 44 different sequence types (STs), 42 serogenotypes and 14 stx subtype combinations. Antibiotic resistance genes were more frequently present in stx1-positive isolates compared to stx2 and stx1 + stx2–positive isolates. The iha, mchB, mchC, mchF, subA, ireA, senB, saa and sigA genes were significantly more frequently present in eae-negative than in eae-positive STEC isolates. Presence of virulence genes encoding type III secretion proteins and adhesins was associated with isolates obtained from patients with bloody diarrhoea. Core genome phylogenetic analysis showed that isolates clustered according to their ST or serogenotypes irrespective of stx subtypes. Isolates obtained from patients with bloody diarrhoea were from diverse phylogenetic backgrounds. Some STEC isolates shared common ancestors with non-STEC isolates. Whole genome sequencing is a powerful tool for clinical microbiology, allowing high-resolution molecular typing, population structure analysis and detailed molecular characterization of strains. STEC isolates of a substantial genetic diversity and of distinct phylogenetic groups were observed in this study

    The Position of High Frequency Waves with Respect to the Granulation Pattern

    Full text link
    High frequency velocity oscillations were observed in the spectral lines Fe I 543.45nm and 543.29nm, using 2D spectroscopy with a Fabry- Perot and speckle reconstruction, at the VTT in Tenerife. We investigate the radial component of waves with frequencies in the range 8 - 22mHz in the internetwork, network and a pore. We find that the occurrence of waves do not show any preference on location and are equally distributed over down-flows and up-flows, regardless of the activity of the observed area in the line of Fe I 543.45nm. The waves observed in the lower formed line of Fe I 543.29nm seem to appear preferentially over down-flows.Comment: Article has 12 pages and 7 images. It is accepted in Solar Physics Journa

    Pathologic features of prostate cancer found at population-based screening with a four-year interval

    Get PDF
    BACKGROUND: The currently recommended frequency for prostate-specific antigen (PSA) screening tests for prostate cancer is 1 year, but the optimal screening interval is not known. Our goal was to determine if a longer interval would compromise the detection of curable prostate cancer. METHODS: A cohort of 4491 men aged 55-75 years, all participants in the Rotterdam section of the European Randomized Study of (population-based) Screening for Prostate Cancer, were invited to participate in an initial PSA screening. Men who received that screening were invited for a second screen 4 years later. Pathology findings from needle biopsy cores were compared for men in both rounds. Statistical tests were two-sided. RESULTS: A total of 4133 men were screened in the first round (the prevalence screen), and 2385 were screened in the second round. The median amount of cancer in needle biopsy sets was 7.0 mm (95% confidence interval [CI] = 5.4 mm to 8.6 mm) in the first round and 4.1 mm (95% CI = 2.6 mm to 5.6 mm) in the second round (P =.001). Thirty-six percent of the adenocarcinomas detected in the first round but only 16% of those detected in the second round had a Gleason score of 7 or higher (mean difference = 20% [95% CI = 10% to 30%]; P<.001). Whereas 25% of the adenocarcinomas detected in the first round had adverse prognostic features, only 6% of those detected in the second round did (mean difference = 19% [95% CI = 11% to 26%]; P<.001). Baseline PSA values were predictive for the amount of tumor in biopsies in men with cancer in the first round but not for that in the second round. CONCLUSION: Most large prostate cancers with high serum PSA levels were effectively detected in a prevalence screen. In this population, a screening interval of 4 years appears to be short enough to constrain the development of large tumors, although it is inconclusive whether this will result in a survival benefit

    Accessing transversity with interference fragmentation functions

    Full text link
    We discuss in detail the option to access the transversity distribution function h1(x)h_1(x) by utilizing the analyzing power of interference fragmentation functions in two-pion production inside the same current jet. The transverse polarization of the fragmenting quark is related to the transverse component of the relative momentum of the hadron pair via a new azimuthal angle. As a specific example, we spell out thoroughly the way to extract h1(x)h_1(x) from a measured single spin asymmetry in two-pion inclusive lepton-nucleon scattering. To estimate the sizes of observable effects we employ a spectator model for the fragmentation functions. The resulting asymmetry of our example is discussed as arising in different scenarios for the transversity.Comment: 17 pages, 15 figures in .eps format included, typesetted in RevTeX and epsfig.sty, submitted to Phys. Rev.

    The ^4He trimer as an Efimov system

    Full text link
    We review the results obtained in the last four decades which demonstrate the Efimov nature of the 4^4He three-atomic system.Comment: Review article for a special issue of the Few-Body Systems journal devoted to Efimov physic

    Toward an internally consistent astronomical distance scale

    Full text link
    Accurate astronomical distance determination is crucial for all fields in astrophysics, from Galactic to cosmological scales. Despite, or perhaps because of, significant efforts to determine accurate distances, using a wide range of methods, tracers, and techniques, an internally consistent astronomical distance framework has not yet been established. We review current efforts to homogenize the Local Group's distance framework, with particular emphasis on the potential of RR Lyrae stars as distance indicators, and attempt to extend this in an internally consistent manner to cosmological distances. Calibration based on Type Ia supernovae and distance determinations based on gravitational lensing represent particularly promising approaches. We provide a positive outlook to improvements to the status quo expected from future surveys, missions, and facilities. Astronomical distance determination has clearly reached maturity and near-consistency.Comment: Review article, 59 pages (4 figures); Space Science Reviews, in press (chapter 8 of a special collection resulting from the May 2016 ISSI-BJ workshop on Astronomical Distance Determination in the Space Age

    Implementation and outcome of robotic liver surgery in the Netherlands: a nationwide analysis

    Get PDF
    Objective:To determine the nationwide implementation and surgical outcome of minor and major robotic liver surgery (RLS) and assess the first phase of implementation of RLS during the learning curve. Background:RLS may be a valuable alternative to laparoscopic liver surgery. Nationwide population-based studies with data on implementation and outcome of RLS are lacking. Methods:Multicenter retrospective cohort study including consecutive patients who underwent RLS for all indications in 9 Dutch centers (August 2014-March 2021). Data on all liver resections were obtained from the mandatory nationwide Dutch Hepato Biliary Audit (DHBA) including data from all 27 centers for liver surgery in the Netherlands. Outcomes were stratified for minor, technically major, and anatomically major RLS. Learning curve effect was assessed using cumulative sum analysis for blood loss. Results:Of 9437 liver resections, 400 were RLS (4.2%) procedures including 207 minor (52.2%), 141 technically major (35.3%), and 52 anatomically major (13%). The nationwide use of RLS increased from 0.2% in 2014 to 11.9% in 2020. The proportion of RLS among all minimally invasive liver resections increased from 2% to 28%. Median blood loss was 150 mL (interquartile range 50-350 mL] and the conversion rate 6.3% (n=25). The rate of Clavien-Dindo grade >= III complications was 7.0% (n=27), median length of hospital stay 4 days (interquartile range 2-5) and 30-day/in-hospital mortality 0.8% (n=3). The R0 resection rate was 83.2% (n=263). Cumulative sum analysis for blood loss found a learning curve of at least 33 major RLS procedures. Conclusions:The nationwide use of RLS in the Netherlands has increased rapidly with currently one-tenth of all liver resections and one-fourth of all minimally invasive liver resections being performed robotically. Although surgical outcomes of RLS in selected patient seem favorable, future prospective studies should determine its added value.Surgical oncolog

    Strategies and performance of the CMS silicon tracker alignment during LHC Run 2

    Get PDF
    The strategies for and the performance of the CMS silicon tracking system alignment during the 2015–2018 data-taking period of the LHC are described. The alignment procedures during and after data taking are explained. Alignment scenarios are also derived for use in the simulation of the detector response. Systematic effects, related to intrinsic symmetries of the alignment task or to external constraints, are discussed and illustrated for different scenarios
    corecore