46 research outputs found

    Vacuum polarization calculations for hydrogenlike and alkalilike ions

    Full text link
    Complete vacuum polarization calculations incorporating finite nuclear size are presented for hydrogenic ions with principal quantum numbers n=1-5. Lithiumlike, sodiumlike, and copperlike ions are also treated starting with Kohn-Sham potentials, and including first-order screening corrections. In both cases dominant Uehling terms are calculated with high accuracy, and smaller Wichmann- Kroll terms are obtained using numerical electron Green's functions.Comment: 23 pages, 1 figur

    Recoil correction to the ground state energy of hydrogenlike atoms

    Get PDF
    The recoil correction to the ground state energy of hydrogenlike atoms is calculated to all orders in \alpha Z in the range Z = 1-110. The nuclear size corrections to the recoil effect are partially taken into account. In the case of hydrogen, the relativistic recoil correction beyond the Salpeter contribution and the nonrelativistic nuclear size correction to the recoil effect, amounts to -7.2(2) kHz. The total recoil correction to the ground state energy in hydrogenlike uranium (^{238}U^{91+}) constitutes 0.46 eV.Comment: 16 pages, 1 figure (eps), Latex, submitted to Phys.Rev.

    Factors Associated with Recurrence of Varicose Veins after Thermal Ablation: Results of The Recurrent Veins after Thermal Ablation Study

    Get PDF
    Background. The goal of this retrospective cohort study (REVATA) was to determine the site, source, and contributory factors of varicose vein recurrence after radiofrequency (RF) and laser ablation. Methods. Seven centers enrolled patients into the study over a 1-year period. All patients underwent previous thermal ablation of the great saphenous vein (GSV), small saphenous vein (SSV), or anterior accessory great saphenous vein (AAGSV). From a specific designed study tool, the etiology of recurrence was identified. Results. 2,380 patients were evaluated during this time frame. A total of 164 patients had varicose vein recurrence at a median of 3 years. GSV ablation was the initial treatment in 159 patients (RF: 33, laser: 126, 52 of these patients had either SSV or AAGSV ablation concurrently). Total or partial GSV recanalization occurred in 47 patients. New AAGSV reflux occurred in 40 patients, and new SSV reflux occurred in 24 patients. Perforator pathology was present in 64% of patients. Conclusion. Recurrence of varicose veins occurred at a median of 3 years after procedure. The four most important factors associated with recurrent veins included perforating veins, recanalized GSV, new AAGSV reflux, and new SSV reflux in decreasing frequency. Patients who underwent RF treatment had a statistically higher rate of recanalization than those treated with laser

    Recoil correction to the bound-electron g factor in H-like atoms to all orders in αZ\alpha Z

    Get PDF
    The nuclear recoil correction to the bound-electron g factor in H-like atoms is calculated to first order in m/Mm/M and to all orders in αZ\alpha Z. The calculation is performed in the range Z=1-100. A large contribution of terms of order (αZ)5(\alpha Z)^5 and higher is found. Even for hydrogen, the higher-order correction exceeds the (αZ)4(\alpha Z)^4 term, while for uranium it is above the leading (αZ)2(\alpha Z)^2 correction.Comment: 6 pages, 3 tables, 1 figur

    A Study of the Δ\Delta^--component of the wave-function in light nuclei

    Full text link
    We have measured cross sections for the (π+,π±p) (\pi^+,\pi^\pm p) reactions on 3H{\rm ^3H}, 4He{\rm ^4He}, 6Li{\rm ^6Li} and 7Li{\rm ^7Li} in quasi-free kinematics at incident pion beam energy 500 MeV. An enhancement of the (π+,πp)(\pi^+,\pi^- p) cross section in this kinematics is observed. If this is interpreted as due to quasi-free scattering from pre-existing Δ\Delta components of the nuclear wave function, the extracted probabilities are in agreement with theoretical expectations.Comment: 3 pages, 3 figures, 1 tabl

    Determination of the neutron electric form factor in quasielastic scattering of polarized electrons from polarized 3He

    Get PDF
    We report a measurement of the asymmetry in spin-dependent quasielastic scattering of longitudinally polarized electrons from a polarized 3He gas target. The asymmetry is measured at kinematics sensitive to the transverse-longitudinal response function RTL(Q2,ω). The value of the neutron electric form factor GEn(Q2=0.16 (GeV/c2))=+0.070±0.100±0.035 is extracted from the asymmetry using a Faddeev calculation of the 3He wave function

    Electromagnetic and Hadron Calorimeters in the MIPP Experiment

    Get PDF
    The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons and nucleons in pi, K and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is to measure the production of forward-going neutrons and photons. The electromagnetic calorimeter consist of 10 lead plates interspersed with proportional chambers. It was followed by the hadron calorimeter with 64 steel plates interspersed with scintillator. The data presented were collected with a variety of targets and beam momenta from 5 GeV/c to 120 GeV/c. The energy calibration of both calorimeters with electrons, pions, kaons, and protons is discussed. The resolution for electrons was found to be 0.27/sqrt(E), and for hadrons the resolution was 0.554/sqrt(E) with a constant term of 2.6%. The performance of the calorimeters was tested on a neutron sample

    Esophageal perforation in South of Sweden: Results of surgical treatment in 125 consecutive patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>For many years there has been a debate as to which is the method of choice in treating patients with esophageal perforation. The literature consists mainly of small case series. Strategies for aiding patients struck with this disease is changing as new and less traumatic treatment options are developing. We studied a relatively large consecutive material of esophageal perforations in an effort to evaluate prognostic factors, diagnostic efforts and treatment strategy in these patients.</p> <p>Methods</p> <p>125 consecutive patients treated at the University Hospital of Lund from 1970 to 2006 were studied retrospectively. Prognostic factors were evaluated using the Cox proportional hazards model.</p> <p>Results</p> <p>Pre-operative ASA score was the only factor that significantly influenced outcome. Neck incision for cervical perforation (n = 8) and treatment with a covered stent with or without open drainage for a thoracic perforation (n = 6) had the lowest mortality. Esophageal resection (n = 8) had the highest mortality. A CAT scan or an oesophageal X-ray with oral contrast were the most efficient diagnostic tools. The preferred treatment strategy changed over the course of the study period, from a more aggressive surgical approach towards using covered stents to seal the perforation.</p> <p>Conclusion</p> <p>Pre-operative ASA score was the only factor that significantly influenced outcome in this study. Treatment strategies are changing as less traumatic options have become available. Sealing an esophageal perforation with a covered stent, in combination with open or closed drainage when necessary, is a promising treatment strategy.</p

    Measurement of inclusive quasielastic scattering of polarized electrons from polarized ³He

    Get PDF
    We report a measurement of the asymmetry in spin-dependent quasielastic scattering of longitudinally polarized electrons from a polarized 3He gas target. This measurement represents the first demonstration of a new method for studying electromagnetic nuclear structure: the scattering of polarized electrons from a polarized nuclear target. The measured asymmetry is in good agreement with a Faddeev calculation and supports the picture of spin-dependent quasielastic scattering from polarized 3He as predominantly scattering from a polarized neutron
    corecore