201 research outputs found

    Primäres zerebelläres T-Zell-Lymphom

    Get PDF
    Zusammenfassung: Primäre T-Zell-Lymphome des zentralen Nervensystems (ZNS) sind selten. Sie müssen differenzialdiagnostisch von reaktiven Läsionen unterschieden werden. Die Diagnosestellung sollte integrativ unter Verwendung von immunhistochemischen, molekulargenetischen und/oder zytogenetischen Methoden erfolgen. Wir beschreiben den Fall eines 50-jährigen Mannes, bei welchem ein primäres zerebelläres T-Zell-Lymphom diagnostiziert und eine klonale T-Zell-Rezeptorgen-Umlagerung nachgewiesen wurde. Nach 2Zyklen Chemotherapie entwickelte der Patient eine Pneumozystis-carinii-Pneumonie und verstarb 10Wochen nach Diagnosestellung. Die Autopsie ergab keinen Residualtumor im ZN

    Propensity score-based analysis of long-term follow-up in patients supported with durable centrifugal left ventricular assist devices:the EUROMACS analysis

    Get PDF
    OBJECTIVES: The HeartWare HVAD (HW) and the HeartMate3 (HM3) are presently the most commonly used continuous-flow left ventricular assist devices worldwide. We compared the outcomes of patients supported with either of these 2 devices based on data from the EUROMACS (European Registry for Patients with Mechanical Circulatory Support). METHODS: A retrospective analysis of the survival and complications profile in propensity score-matched adult patients enrolled in the EUROMACS between 01 January 2016 and 01 September 2020 and supported with either an HW or HM3. Matching included demographic parameters, severity of cardiogenic shock and risk-modifying end-organ parameters that impact long-term survival. Survival on device and major postoperative adverse events were analysed. RESULTS: Following 1:1 propensity score matching, each group consisted of 361 patients. Patients were well balanced (<0.1 standardized mean difference). The median follow-up was similar in both groups [396 (interquartile range (IQR) 112-771) days for HW and 376 (IQR 100-816) days for HM3]. The 2-year survival was similar in both groups [HW: 61% 95% confidence interval (CI) (56-67%) vs HM3: 68% 95% CI (63-73%) (stratified hazard ratio for mortality: 1.13 95% CI (0.83-1.54), P = 0.435].The cumulative incidence for combined major adverse events and unexpected readmissions was similar in both groups [subdistribution hazard ratio (SHR) 1.0 (0.84-1.21), P = 0.96]. Patients in the HW group demonstrated a higher risk of device malfunction [SHR 2.44 (1.45-3.71), P < 0.001], neurological dysfunction [SHR 1.29 (1.02-1.61), P = 0.032] and intracranial bleeding [SHR 1.76 (1.13-2.70), P = 0.012]. CONCLUSIONS: Mid-term survival in both groups was similar in a propensity-matched analysis. The risk of device malfunction, neurological dysfunction and intracranial bleeding was significantly higher in HW patients

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    Get PDF
    OBJECTIVES: A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS: The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months contin

    Impact of extra-corporeal life support (ECLS) cannulation strategy on outcome after durable mechanical circulation support system implantation on behalf of durable MCS after ECLS Study Group

    Get PDF
    Background: The literature on outcomes of patients requiring durable mechanical circulatory support (MCS) after extra-corporeal life support (ECLS) is limited. The aim of this study was to investigate the impact of preoperative ECLS cannulation on postoperative outcome after durable MCS implantation. Methods: The durable MCS after ECLS registry is a multicenter retrospective study that gathered data on consecutive patients who underwent durable MCS implantation after ECLS between January 2010 and August 2018 in eleven high volume European centers. Patients who underwent the implantation of total artificial heart, pulsatile pumps, or first-generation pumps after ECLS were excluded from the analysis. The remaining patients were divided into two groups; central ECLS group (cECLS) and peripheral ECLS group (pECLS). A 1:1 propensity score analysis was performed to identify two matched groups. The outcome of these two groups was compared. Results: A total of 531 durable MCS after ECLS were implanted during this period. The ECLS cannulation site was peripheral in 87% (n=462) and central in 13% (n=69) of the patients. After excluding pulsatile pumps and total artificial heart patients, a total of 494 patients remained (pECLS =434 patients, cECLS =60 patients). A 1:1 propensity score analysis resulted in 2 matched groups (each 55 patients) with median age of 54 years (48-60 years) in cECLS group and 54 years (43-60 years) in pECLS group. HeartWare HVAD (Medtronic, Minneapolis, MN) was implanted in the majority of the patients (cECLS =71% vs. pECLS =76%, P=0.67). All postoperative morbidities were comparable between the groups. The thirty-day, one year and long-term survival was comparable between the groups (P=0.73). Conclusions: The cannulation strategy of ECLS appears to have no impact on the post-operative outcome after durable MCS implantation

    The European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery:third report

    Get PDF
    OBJECTIVES: In the third report of the European Registry for Patients with Mechanical Circulatory Support of the European Association for Cardio-Thoracic Surgery, outcomes of patients receiving mechanical circulatory support are reviewed in relation to implant era. METHODS: Procedures in adult patients (January 2011-June 2020) were included. Patients from centres with 3 months). Risk factors for death were explored using univariable Cox regression with a stepwise time-varying hazard ratio (3 months). RESULTS: In total, 4834 procedures in 4486 individual patients (72 hospitals) were included, with a median follow-up of 1.1 (interquartile range: 0.3-2.6) years. The annual number of implants (range: 346-600) did not significantly change (P = 0.41). Both Interagency Registry for Mechanically Assisted Circulatory Support class (classes 4-7: 23, 25 and 33%; P 3 months: 0.45). Bilirubin and creatinine levels were significant risk factors in the early phase but not in the late phase after the implant. CONCLUSIONS: In its 10 years of existence, EUROMACS has become a point of reference enabling benchmarking and outcome monitoring. Patient characteristics and outcomes changed between implant eras. In addition, both occurrence of outcomes and risk factor weights are time dependent

    Paediatric aortic valve replacement using decellularized allografts

    Get PDF
    OBJECTIVES: Options for paediatric aortic valve replacement (AVR) are limited if valve repair is not feasible. Results of paediatric Ross procedures are inferior to adult Ross results, and mechanical AVR imposes constant anticoagulation with the inherent risks.METHODS: The study design was a prospective, multicentre follow-up of all paediatric patients receiving decellularized aortic homografts (DAHs) for AVR in 8 European centres.RESULTS: A total of 106 children (77 boys) were operated (mean age 10.1 +/- 4.8 years, DAH diameter 20.5 +/- 3.8 mm). A total of 60 (57%) had undergone previous surgical interventions: 34 with 1, 15 with 2 and 11 with >3. There was one early death in a 12-year-old girl, who underwent her fourth aortic valve operation, due to intracerebral haemorrhage on extracorporeal membrane oxygenation after coronary reimplantation problems following 3-sinus reconstruction 1 year earlier. One 2-year-old patient died due to sepsis 2 months postoperatively with no evidence for endocarditis. In addition, a single pacemaker implantation was necessary and a 2.5-year-old girl underwent successful HTx due to chronic myocardial failure despite an intact DAH. After a mean follow-up of 3.30 +/- 2.45 years, primary efficacy end points mean peak gradient (18.1 +/- 20.9 mmHg) and regurgitation (mean 0.61 +/- 0.63, grade 0-3) were very good. Freedom from death/explantation/endocarditis/bleeding/stroke at 5 years was 97.8 +/- 1.6/85.0 +/- 7.4/100/100/100% respectively. Calculated expected adverse events were lower for DAH compared to cryopreserved homograft patients (mean age 8.9 years), lower than in Ross patients (9.4 years) and in the same range as mechanical AVR (12.8 years).CONCLUSIONS: Even though the overall number of paediatric DAH patients and the follow-up time span are still limited, our data suggest that DAHs may present a promising additional option for paediatric AVR.Thoracic Surger
    • …
    corecore