13 research outputs found

    Partial Discharges detection in 1 MV power supplies in MITICA experiment, the ITER Heating Neutral Beam Injector prototype

    Full text link
    MITICA (Megavolt ITER Injector & Concept Advancement), the full scale prototype of ITER Heating Neutral Beam, is under realization at the Neutral Beam Test Facility (Padova, Italy). It is designed to deliver 16.5 MW to ITER plasma, obtained by accelerating negative Deuterium ions up to 1 MeV for a total ion current of 40 A and then neutralized. MITICA Acceleration Power Supply is composed of several non-standard equipment, beyond industrial standard for insulation voltage level (-1 MVdc) and dimensions. Voltage withstand tests (up to 1.265 MVdc) have been performed in five subsequent steps (from 2018 to 2019), according to the installation progress, after connecting equipment belonging to different procurements. During integrated commissioning, started in 2021, two breakdowns occurred in a position of the HV plant not still identified, so they could be occurred either in air or in SF6. To identify the locations of possible weak insulation points, the existing diagnostics for partial discharge detection (the precursor of breakdowns) as a first step have been improved on air-insulated parts by consisting in a set of instrumentation, like capacitive probes and off-the-shelf instruments for AC application (acoustic and electromagnetic sensors). The paper deals with the instruments qualification to assess their suitability for DC usage and then with the investigation performed in MITICA, in particular: 1) sensitivity assessment campaign, with artificially produced corona effect to identify the minimum threshold of each diagnostics 2) voltage application to MITICA plant, moving the instrumentation around equipment and increasing progressively the voltage looking for corona phenomena to identify possible weak insulation points.Comment: Nine pages, twelve figures, accepted manuscript of a paper published in Fusion Engineering and Desig

    Redox active Double Wall Carbon Nanotubes show intrinsic anti-proliferative effects and modulate autophagy in cancer cells

    Get PDF
    In Double-Walled-Carbon-Nanotubes (DWCNTs) the outer shell screens the inner one from the external environment. As a consequence, the electronic properties of the smaller tube are enhanced and DWCNTs have therefore been advocated for a number of uses. In their raw form theymay contain small metallic clusters, left over from the catalytic process, that can give them a redox activity characterized by redox potentials in the range of one hundred millivolts and able to affect biological systems. Indeed, we find that redox active raw-DWCNTs inhibit rat colorectal cancer cell proliferation by blocking cells in the G2 phase through ROS generation by tumor cells. We show that raw-DWCNTs could also modulate autophagy in tumor cells through induction of intracellular acidification. To the best of our knowledge, this is the first time that DWCNTs have been found to inhibit proliferation and modulate autophagy in cancer cells. Our work further supports previous studies that provided promising results on the possibility of future applications of Carbon Nanotubes (CNTs) in nanomedicine

    Overview on electrical issues faced during the SPIDER experimental campaigns

    Full text link
    SPIDER is the full-scale prototype of the ion source of the ITER Heating Neutral Beam Injector, where negative ions of Hydrogen or Deuterium are produced by a RF generated plasma and accelerated with a set of grids up to ~100 keV. The Power Supply System is composed of high voltage dc power supplies capable of handling frequent grid breakdowns, high current dc generators for the magnetic filter field and RF generators for the plasma generation. During the first 3 years of SPIDER operation different electrical issues were discovered, understood and addressed thanks to deep analyses of the experimental results supported by modelling activities. The paper gives an overview on the observed phenomena and relevant analyses to understand them, on the effectiveness of the short-term modifications provided to SPIDER to face the encountered issues and on the design principle of long-term solutions to be introduced during the currently ongoing long shutdown.Comment: 8 pages, 12 figures. Presented at SOFT 202

    Predicting needlestick and sharps injuries in nursing students: Development of the SNNIP scale

    Get PDF
    © 2020 The Authors. Nursing Open published by John Wiley & Sons Ltd. Aim: To develop an instrument to investigate knowledge and predictive factors of needlestick and sharps injuries (NSIs) in nursing students during clinical placements. Design: Instrument development and cross-sectional study for psychometric testing. Methods: A self-administered instrument including demographic data, injury epidemiology and predictive factors of NSIs was developed between October 2018–January 2019. Content validity was assessed by a panel of experts. The instrument's factor structure and discriminant validity were explored using principal components analysis. The STROBE guidelines were followed. Results: Evidence of content validity was found (S-CVI 0.75; I-CVI 0.50–1.00). A three-factor structure was shown by exploratory factor analysis. Of the 238 participants, 39% had been injured at least once, of which 67.3% in the second year. Higher perceptions of “personal exposure” (4.06, SD 3.78) were reported by third-year students. Higher scores for “perceived benefits” of preventive behaviours (13.6, SD 1.46) were reported by second-year students

    Predicting needlestick and sharps injuries in nursing students: Development of the SNNIP scale

    Get PDF

    Loop Electrostatics Asymmetry Modulates the Preexisting Conformational Equilibrium in Thrombin

    No full text
    none9siThrombin exists as an ensemble of active (E) and inactive (E∗) conformations that differ in their accessibility to the active site. Here we show that redistribution of the E∗-E equilibrium can be achieved by perturbing the electrostatic properties of the enzyme. Removal of the negative charge of the catalytic Asp102 or Asp189 in the primary specificity site destabilizes the E form and causes a shift in the 215-217 segment that compromises substrate entrance. Solution studies and existing structures of D102N document stabilization of the E∗ form. A new high-resolution structure of D189A also reveals the mutant in the collapsed E∗ form. These findings establish a new paradigm for the control of the E∗-E equilibrium in the trypsin foldopenPozzi, Nicola; Zerbetto, Mirco; Acquasaliente, Laura; Tescari, Simone; Frezzato, Diego; Polimeno, Antonino; Gohara, David W.; Di Cera, Enrico; De Filippis, VincenzoPozzi, Nicola; Zerbetto, Mirco; Acquasaliente, Laura; Tescari, Simone; Frezzato, Diego; Polimeno, Antonino; Gohara, David W.; Di Cera, Enrico; DE FILIPPIS, Vincenz

    Conoscenza sull’igiene delle mani tra personale e studenti di un grande policlinico di Roma

    No full text
    Introduzione Il lavaggio appropriato delle mani è un fondamentale strumento di pre- venzione delle infezioni correlate all’assistenza. Nel corso del 2019, presso il policlinico universitario Sant’Andrea di Roma sono stati in- stallati oltre 250 erogatori di gel idroalcolico per il lavaggio antisettico all’ingresso di ogni stanza di degenza e nei vari servizi dell’ospedale. Per questo motivo, prima di avviare attività di formazione e sensibiliz- zazione, si è ritenuto utile condurre una indagine preliminare sulle reali conoscenze relative al lavaggio delle mani del personale sanitario e degli studenti. Materiali e metodi È stato condotto uno studio trasversale su medici, infermieri e studenti presso l’ospedale universitario Sant’Andrea di Roma (450 posti letto). Il livello di corretta conoscenza è stato valutato mediante il questionario dell’Organizzazione Mondiale della Sanità (OMS), che è strutturato in oltre 20 domande a riposta multipla e domande “si” o “no”. Il questio- E60 nario è stato somministrato ad un campione della popolazione di riferi- mento convocato in una serie di riunioni collegiali (rispondenza 100%). Risultati Sono stati arruolati 167 soggetti, di cui 26 (15,6%) medici, 47 (28,1%) infermieri, 36 (21,6%) studenti di Medicina e 58 (34,7%) studenti di Infermieristica ed Ostetricia, che hanno compilato il questionario nel rispetto dell’anonimato. L’età media dei singoli gruppi di studio è sta- ta: 50,9 anni (range 27-65) nei medici, 46,5 anni (range 21-59) negli infermieri, 22,2 anni (range 18-27) negli studenti di medicina, e 21,8 anni (range 19-31) per gli studenti di infermieristica ed ostetricia. In ge- nerale, dall’analisi di ciascun gruppo oggetto di studio, è emerso come gli studenti di medicina abbiano risposto correttamente all’80,9% delle domande, gli studenti di infermieristica ed ostetricia al 78,1%, i medici al 77,5% e gli infermieri al 77,1%. Innanzitutto, la conoscenza generale sui meccanismi di trasmissione e sui principi generali di prevenzione è risultata discreta, seppure si debba rilevare un livello di conoscenza leggermente maggiore negli infermieri rispetto ai medici, sia tra gli ope- ratori sanitari che tra gli studenti. In particolare sulle “principali vie di trasmissione crociata tra pazienti”, infermieri e studenti di infermieri- stica hanno evidenziato una conoscenza significativamente maggiore rispetto a medici e studenti di medicina (89,5% vs 81,0%; p = 0,033). Infatti, circa un 1/3 dei medici risultava carente sul lavaggio delle mani prima e dopo il contatto con il paziente. Non sono emerse differenze significative di genere. Il campione ha evidenziato una corretta cono- scenza dei principali momenti (five moments - OMS) per l’effettuazione del lavaggio delle mani ed anche sui fattori favorenti la colonizzazione delle mani, tranne che per l’uso delle creme per le mani (circa il 50%), dove i medici hanno risposto significativamente in modo più corretto degli infermieri (61,5% vs 44,7%; p = 0,032). Considerando la corretta igiene delle mani durante le attività assistenziali è emerso come il 57,7% dei medici ed il 61,7% degli infermieri avessero risposto in modo errato non valutando la cartella clinica come possibile mezzo di trasmissione indiretta. Da sottolineare come il 40% - 50% degli studenti medici ed in- fermieri, che svolgono tirocinio pratico, non avessero cognizioni corrette sui comportamenti in caso di esposizione a sangue ed altri liquidi bio- logici. Da considerare come anche 1/3 dei medici non avessero risposto correttamente su tali tematiche. Riguardo alle conoscenze specifiche sul lavaggio idroalcolico delle mani, le conoscenze generali sono apparse discrete, seppur con alcune importanti eccezioni; in particolare, per il quesito riguardante il tempo minimo di utilizzo di prodotto a base alco- lica per espletare la sua funzione, la risposta è stata errata nel 68,0% dei medici, nel 59,6% tra infermieri, nel 51,8% tra gli studenti di infermie- ristica ed ostetricia e nel 50,0% del gruppo studenti di medicina. Strati- ficando i dati per un confronto tra area infermieristica e medica, questi ultimi conoscevano meno la procedura con frizione alcolica (78,1% vs 47,6%; p < 0,001). Anche la eventuale corretta sequenza tra lavaggio e frizione appariva correttamente conosciuta solo dal 51,1% degli infer- mieri, 50,0% dei medici, 35,1% degli studenti di medicina e 32,8% degli studenti di infermieristica ed ostetricia. Conclusioni Lo studio ha evidenziato un generale discreto livello di conoscenza, sep- pure siano emersi alcuni aspetti critici riguardo alle trasmissioni crocia- te. Il lavaggio idroalcolico è conosciuto maggiormente dalla componen- te infermieristica rispetto a quella medica. Inoltre, si deve migliorare la conoscenza di tutti gli studenti che svolgono tirocinio pratico. Per questi motivi sarà fondamentale implementare gli attuali programmi di forma- zione con interventi di didattica pratica ed esercitazione rivolti sia agli operatori sanitari che agli studenti dei vari corsi. Bibliografia Allegranzi B, Pittet D. Role of hand hygiene in healthcare-associated infection prevention. J Hosp Infect 2009;73:304-15. Pittet D, Hugonnet S, Harbarth S, et al. Effectiveness of a hospital- wide programme to improve compliance with hand hygiene. Lancet 2000;356:1307-12. WHO guidelines on hand hygiene in health care. World Health Organ
    corecore