273 research outputs found

    Low Force Icy Regolith Penetration Technology

    Get PDF
    Recent data from the Moon, including LCROSS data, indicate large quantities of water ice and other volatiles frozen into the soil in the permanently shadowed craters near the poles. If verified and exploited, these volatiles will revolutionize spaceflight as an inexpensive source of propellants and other consumables outside Earth's gravity well. This report discusses a preliminary investigation of a method to insert a sensor through such a soiVice mixture to verify the presence, nature, and concentration of the ice. It uses percussion to deliver mechanical energy into the frozen mixture, breaking up the ice and decompacting the soil so that only low reaction forces are required from a rover or spacecraft to push the sensor downward. The tests demonstrate that this method may be ideal for a small platform in lunar gravity. However, there are some cases where the system may not be able to penetrate the icy soil, and there is some risk ofthe sensor becoming stuck so that it cannot be retracted, so further work is needed. A companion project (ISDS for Water Detection on the Lunar Surface) has performed preliminary investigation of a dielectric/thermal sensor for use with this system

    Low Force Penetration of Icy Regolith

    Get PDF
    A percussive cone penetrometer measures the strength of granular material by using percussion to deliver mechanical energy into the material. A percussive cone penetrometer was used in this study to penetrate a regolith ice mixture by breaking up ice and decompacting the regolith. As compared to a static cone penetrometer, percussion allows low reaction forces to push a penetrometer probe tip more easily into dry regolith in a low gravity environment from a planetary surface rover or a landed spacecraft. A percussive cone penetrates icy regolith at ice concentrations that a static cone cannot penetrate. In this study, the percussive penetrator was able to penetrate material under 65 N of down-force which could not be penetrated using a static cone under full body weight. This paper discusses using a percussive cone penetrometer to discern changes in the concentration of water-ice in a mixture of lunar regolith simulant and ice to a depth of one meter. The rate of penetration was found to be a function of the ice content and was not significantly affected by the down-force. The test results demonstrate that this method may be ideal for a small platform in a reduced gravity environment. However, there are some cases where the system may not be able to penetrate the icy regolith, and there is some risk of the probe tip becoming stuck so that it cannot be retracted. It is also shown that a percussive cone penetrometer could be used to prospect for water ice in regolith at concentrations as high as 8 by weight

    Resource Prospector Instrumentation for Lunar Volatiles Prospecting, Sample Acquisition and Processing

    Get PDF
    Data gathered from lunar missions within the last two decades have significantly enhanced our understanding of the volatile resources available on the lunar surface, specifically focusing on the polar regions. Several orbiting missions such as Clementine and Lunar Prospector have suggested the presence of volatile ices and enhanced hydrogen concentrations in the permanently shadowed regions of the moon. The Lunar Crater Observation and Sensing Satellite (LCROSS) mission was the first to provide direct measurement of water ice in a permanently shadowed region. These missions with other orbiting assets have laid the groundwork for the next step in the exploration of the lunar surface; providing ground truth data of the volatiles by mapping the distribution and processing lunar regolith for resource extraction. This next step is the robotic mission Resource Prospector (RP). Resource Prospector is a lunar mission to investigate 'strategic knowledge gaps' (SKGs) for in-situ resource utilization (ISRU). The mission is proposed to land in the lunar south pole near a permanently shadowed crater. The landing site will be determined by the science team with input from broader international community as being near traversable landscape that has a high potential of containing elevated concentrations of volatiles such as water while maximizing mission duration. A rover will host the Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload for resource mapping and processing. The science instruments on the payload include a 1-meter drill, neutron spectrometer, a near infrared spectrometer, an operations camera, and a reactor with a gas chromatograph-mass spectrometer for volatile analysis. After the RP lander safely delivers the rover to the lunar surface, the science team will guide the rover team on the first traverse plan. The neutron spectrometer (NS) and near infrared (NIR) spectrometer instruments will be used as prospecting tools to guide the traverse path. The NS will map the water-equivalent hydrogen concentration as low as 0.5% by weight to an 80 centimeter depth as the rover traverses the lunar landscape. The NIR spectrometer will measure surficial H2O/OH as well as general mineralogy. When the prospecting instruments identify a potential volatile-rich area during the course of a traverse, the prospect is then mapped out and the most promising location identified. An augering drill capable of sampling to a depth of 100 centimeters will excavate regolith for analysis. A quick assay of the drill cuttings will be made using an operations camera and NIR spectrometer. With the water depth confirmed by this first auguring activity, a regolith sample may be extracted for processing. The drill will deliver the regolith sample to a crucible that will be sealed and heated. Evolved volatiles will be measured by a gas chromatograph-mass spectrometer and the water will be captured and photographed. RP is a solar powered mission, which given the polar location translates to a relatively short mission duration on the order of 4-15 days. This short mission duration drives the concept of operations, instrumentation, and data analysis towards critical real time analysis and decision support. Previous payload field tests have increased the fidelity of the hardware, software, and mission operations. Current activities include a mission level field test to optimize interfaces between the payload and rover as well as better understand the interaction of the science and rover teams during the mission timeline. This paper will include the current status of the science instruments on the payload as well as the integrated field test occurring in fall of 2015. The concept of operations will be discussed, including the real time science and engineering decision-making process based on the critical data from the instrumentation. The path to flight will be discussed with the approach to this ambitious low cost mission

    Volatiles Loss from Water Bearing Regolith Simulant at Lunar Environments

    Get PDF
    In-Situ Resource Utilization (ISRU) enables future planetary exploration by using local resources to acquire mission consumables. Water-bearing regolith has been identified on the moon in the permanently shadowed craters. Missions designed to retrieve these resources will require testing in relevant environments. The Planetary Surface Simulation Facility (otherwise known as VF-13) at the NASA Glenn Research Center can create these relevant environments for ground based testing. This dirty thermal vacuum chamber is 3.6 m tall, 1.5 m in diameter, and can achieve pressures on the order of 10-6 Torr. The internal wall of the chamber and the soil bin are separately temperature controlled using liquid nitrogen. For the past four years, the chamber has been used by NASA's Resource Prospector to characterize volatiles loss during regolith sampling operations. Observations from 43 samples suggest agitating the sample during delivery has a significant impact on the volatiles loss. Calculated mass loss rates are consistent for similar size samples. However, the variations in moisture loss do not clearly correlate with measured conditions. Continued testing will examine the impacts of the mechanical sample delivery process

    Residual sleepiness after N(2)O sedation: a randomized control trial [ISRCTN88442975]

    Get PDF
    BACKGROUND: Nitrous oxide (N(2)O) provides sedation for procedures that result in constant low-intensity pain. How long do individuals remain sleepy after receiving N(2)O? We hypothesized that drug effects would be apparent for an hour or more. METHODS: This was a randomized, double blind controlled study. On three separate occasions, volunteers (N = 12) received 100% oxygen or 20% or 40% N(2)O for 30 min. Dependent measures included the multiple sleep latency test (MSLT), a Drug Effects/Liking questionnaire, visual analogue scales, and five psychomotor tests. Repeated measures analysis of variance was performed with drug and time as factors. RESULTS: During inhalation, drug effects were apparent based on the questionnaire, visual analogue scales, and psychomotor tests. Three hours after inhaling 100% oxygen or 20% N(2)O, subjects were sleepier than if they breathed 40% N(2)O. No other drug effects were apparent 1 hour after inhalation ceased. Patients did not demonstrate increased sleepiness after N(2)O inhalation. CONCLUSION: We found no evidence for increased sleepiness greater than 1 hour after N(2)O inhalation. Our study suggests that long-term effects of N(2)O are not significant

    Post-puff respiration measures on smokers of different tar yield cigarettes

    Get PDF
    The purpose of this study was to determine the effect of different tar yield cigarette brands on the post-puff inhalation/exhalation depth and duration for established smokers of the brands. The study was conducted with 74 established smokers of 1–17 mg Federal Trade Commission (FTC) tar products. The subjects were participating in a five-day inpatient clinical biomarker study during which time they were allowed to smoke their own brand of cigarette whenever they wished. On two separate days, the subjects' breathing pattern was measured using respiratory inductive plethysmography while they smoked one cigarette. This enabled the measurement of the post-puff inhalation volume, exhalation volume, inhalation duration, and exhalation duration for each subject after each puff on two of their own brand of cigarettes

    Documenting Surface and Sub-surface Volatiles While Drilling in Frozen Lunar Simulant

    Get PDF
    NASA's Resource Prospector (RP) mission is intended to characterize the three-dimensional nature of volatiles in lunar polar regions and permanently shadowed regions. RP is slated to carry two instruments for prospecting purposes. These include the Neutron Spectrometer System (NSS) and Near-Infrared Volatile Spectrometer System (NIRVSS). A Honybee Robotics drill (HRD) is intended to sample to depths of 1 m, and deliver a sample to a crucible that is processed by the Oxygen Volatile Extraction Node (OVEN) where the soil is heated and evolved gas is delivered to the gas chromatograph / mass spectrometer of the Lunar Advanced Volatile Analysis system (LAVA). For several years, tests of various sub-systems have been undertaken in a large cryo-vacuum chamber facility (VF-13) located at Glenn Research Center. In these tests a large tube (1.2 m high x 25.4 cm diameter) is filled with lunar simulant, NU-LHT-3M, prepared with known abundances of water. There are thermo-couples embedded at different depths, and also across the surface of the soil tube. The soil tube is placed in the chamber and cooled with LN2 as the pressure is reduced to approx.5-6x10(exp -6) Torr. Here we discuss May 2016 tests where two soil tubes were prepared and placed in the chamber. Also located in the chamber were 5 crucibles, an Inficon mass spectrometer, and a trolly permitting x-y translation, where the HRD and NIRVSS, were mounted. The shroud surrounding the soil tube was held at different temperatures for each tube to simulate a warm and cold lunar environment

    The Sample Handling System for the Mars Icebreaker Life Mission: from Dirt to Data

    Get PDF
    The Mars icebreaker life mission will search for subsurface life on mars. It consists of three payload elements: a drill to retrieve soil samples from approx. 1 meter below the surface, a robotic sample handling system to deliver the sample from the drill to the instruments, and the instruments themselves. This paper will discuss the robotic sample handling system
    • …
    corecore