    Impact analysis of low velocity to composite box containting water

    Get PDF
    A series of experimental studies were conducted for low velocity impact on a composite box containing water in order to study the Fluid-Structure Interaction (FSI). Finally, a computational study was conducted to supplement the experimental study. The water level inside the composite box was varied incrementally from 0% (i.e. no water) to 100% (full water). The impact velocity was also changed. In the experimental study, strain gages and the load cell were used to measure the strain responses at the front, side, and back surfaces as well as the impact force. The results showed that the FSI effect was significant to the structural responses depending on the water level. The effect of the baffle was different among the front, side and back surfaces. Both experimental and numerical results agreed well.Naval Postgraduate SchoolApproved for public release; distribution is unlimited

    Study on Personal Characteristics and Emotional Affordances through User Activity Analysis

    Get PDF
    Design methodology should address psychological and cognitive aspects based on human emotion and feeling as well as physical and functional aspects based on product structure. Donald Norman introduced perceived affordances as characteristics in the appearance of an object that gives clues for its proper operations. We conducted a case study in a public space - building lobby - used by many general people. User activities and behaviors were analyzed in several specific tasks given to twenty participants with similar cultural background in the lobby of a building they have never been to before. Then we identified affordances and building structure elements, called affordance features, critically related to those affordances. While performing the tasks in the same building lobby, user activities can be classified into several different groups for each task based on affordance features involved in their activities. These user activity differences are then compared with their personal cognitive characteristics derived from their perception and judgment preferences using intuitive and factual perception orientation and objective and subjective decision making inclination respectively. For user of less common activities for some tasks, personal cognitive characteristics have been identified. This study could help in affordance-based design so that alternative affordance features are designed considering diverse user cognitive characteristics

    Relationship between the Retinal Thickness Analyzer and the GDx VCC Scanning Laser Polarimeter, Stratus OCT Optical Coherence Tomograph, and Heidelberg Retina Tomograph II Confocal Scanning Laser Ophthalmoscopy

    Get PDF
    PURPOSE: To assess the relationship between the retinal thickness analyzer (RTA) parameters, and those of the GDx VCC scanning laser polarimeter (GDx VCC), Stratus OCT optical coherence tomography (Stratus OCT), and Heidelberg retinal tomograph II confocal scanning laser ophthalmoscopy (HRT II). METHODS: Twenty-nine primary open-angle glaucoma patients were retrospectively included in this study. Measurements were obtained using the RTA, GDx VCC, Stratus OCT, and HRT II. We calculated the correlation coefficients between the parameters of RTA and those of the other studies. RESULTS: Among the optic disc parameters of RTA, the cup volume was best correlated with Stratus OCT (R=0.780, p<0.001) and HRT II (R=0.896, p<0.001). Among the posterior pole retinal thickness parameters, the posterior pole abnormally thin area (PPAT) of the RTA and the inferior average of the GDx VCC were best correlated (R=-0.596, p=0.001). The PPAT of the RTA and the inferior maximum of the Stratus OCT were best correlated (R=-0.489, p=0.006). The perifoveal minimum thickness (PFMT) of the RTA and the cup shape measurement of the HRT II were best correlated (R=-0.565, p=0.004). CONCLUSIONS: Many RTA optic disc parameters were significantly correlated with those of the Stratus OCT and HRT II. The RTA posterior pole retinal thickness parameters were significantly correlated with those of the GDx VCC, Stratus OCT and HRT II. The RTA optic disc and posterior pole retinal thickness parameters may be valuable in the diagnosis of glaucomaope

    Measuring the maturity of open access: a preliminary study

    Get PDF
    Open access is an important part of scholarly communication, and it has been a global phenomenon. The growth of open access brings several signif-icant benefits to the general public as well as researchers, ultimately leads to the advancement of science. For the continuous growth and development of open access, it is necessary to measure the degree of maturity of open ac-cess. However, there is not much discussion about the assessment frame-work for open access. This study aims to propose an assessment framework of open access maturity. For the purpose of this study, we conducted an analysis with a total of 24 literatures relevant to the digital maturity, the ma-turity of open data/open science, and major open access initiatives. For digi-tal maturity, 18 articles were analyzed: 10 articles for generic purpose model, and 8 articles for industry-specific model. In addition, three articles on the maturity of open data/open science were analyzed and three major open ac-cess initiatives. In preliminary analysis results, three dimensions with 13 be-longing items were proposed for measuring the maturity of open access. Three dimensions are OA Policy, OA capability, and Openness quality. For OA policy, there are three items such as OA policy document, OA govern-ance, and OA strategy. For OA Capability, finance for OA, people for OA, culture for OA, and collaboration for OA are proposed. For Openness Quali-ty dimension, six items are suggested: submission and review, author rights, user rights, findability, accessibility, and monitoring

    Mind bomb 1 in the lymphopoietic niches is essential for T and marginal zone B cell development

    Get PDF
    Notch signaling regulates lineage decisions at multiple stages of lymphocyte development, and Notch activation requires the endocytosis of Notch ligands in the signal-sending cells. Four E3 ubiquitin ligases, Mind bomb (Mib) 1, Mib2, Neuralized (Neur) 1, and Neur2, regulate the Notch ligands to activate Notch signaling, but their roles in lymphocyte development have not been defined. We show that Mib1 regulates T and marginal zone B (MZB) cell development in the lymphopoietic niches. Inactivation of the Mib1 gene, but not the other E3 ligases, Mib2, Neur1, and Neur2, abrogated T and MZB cell development. Reciprocal bone marrow (BM) transplantation experiments revealed that Mib1 in the thymic and splenic niches is essential for T and MZB cell development. Interestingly, when BM cells from transgenic Notch reporter mice were transplanted into Mib1-null mice, the Notch signaling was abolished in the double-negative thymocytes. In addition, the endocytosis of Dll1 was impaired in the Mib1-null microenvironment. Moreover, the block in T cell development and the failure of Dll1 endocytosis were also observed in coculture system by Mib1 knockdown. Our study reveals that Mib1 is the essential E3 ligase in T and MZB cell development, through the regulation of Notch ligands in the thymic and splenic microenvironments

    The Expression Patterns of FAM83H and PANX2 Are Associated With Shorter Survival of Clear Cell Renal Cell Carcinoma Patients

    Get PDF
    FAM83H is primarily known for its role in amelogenesis; however, recent reports suggest FAM83H might be involved in tumorigenesis. Although the studies of FAM83H in kidney cancer are limited, a search of the public database shows a significant association between FAM83H and pannexin-2 (PANX2) in clear cell renal cell carcinomas (CCRCCs). Therefore, we evaluated the clinicopathological significance of the immunohistochemical expression of FAM83H and PANX2 in 199 CCRCC patients. The expression of FAM83H and PANX2 were significantly associated with each other. In univariate analysis, individual, and co-expression pattern of FAM83H and PANX2 was significantly associated with shorter overall survival (OS) and relapse-free survival (RFS) of CCRCC patients: nuclear expression of FAM83H (OS; P &lt; 0.001, RFS; P &lt; 0.001), cytoplasmic expression of FAM83H (OS; P &lt; 0.001, RFS; P &lt; 0.001), nuclear expression of PANX2 (OS; P &lt; 0.001, RFS; P &lt; 0.001), cytoplasmic expression of PANX2 (OS; P &lt; 0.001, RFS; P &lt; 0.001), co-expression pattern of nuclear FAM83H and nuclear PANX2 (OS; P &lt; 0.001, RFS; P &lt; 0.001). In multivariate analysis, nuclear expression of FAM83H (OS; P &lt; 0.001, RFS; P = 0.003) and the co-expression pattern of nuclear FAM83H and PANX2 (OS; P &lt; 0.001, RFS; P &lt; 0.001) were independent indicators of shorter survival of CCRCC patients. Cytoplasmic expression of FAM83H was associated with shorter RFS (P = 0.030) in multivariate analysis. In Caki-1 and Caki-2 CCRCC cells, knock-down of FAM83H decreased PANX2 expression and cell proliferation, and overexpression of FAM83H increased PANX2 expression and cell proliferation. These results suggest that FAM83H and PANX2 might be involved in the progression of CCRCC in a co-operative manner, and their expression might be used as novel prognostic indicators for CCRCC patients

    Rupture of endotracheal tube cuff during robot-assisted endoscopic thyroidectomy -A case report-

    Get PDF
    We encountered a case of a rupture of an endotracheal tube cuff during robot-assisted thyroid surgery in a 35-year-old male patient. Two hours after commencing surgery, the bellows of the ventilator were not filled and a rupture of the endotracheal tube cuff was suspected. Once the robot-manipulator is engaged, the position of the operating table cannot be altered without removing it from the patient. Reintubation with direct laryngoscopy was performed with difficulty in the narrow space between the patient's head and robot-manipulator without moving the robot away from the patient. The rupture of the endotracheal tube cuff was confirmed by observing air bubbles exiting from the balloon in water. The patient was discharged 3 days after surgery without complications. In robot-assisted thyroid surgery, a preoperative arrangement of the robot away from the patient's head to obtain easy access to the patient is essential for safe anesthetic care
    • …