27 research outputs found
Electrocardiographic findings in patients with arrhythmogenic cardiomyopathy and right bundle branch block ventricular tachycardia
AIMS: Little is known about patients with right bundle branch block (RBBB)-ventricular tachycardia (VT) and arrhythmogenic cardiomyopathy (ACM). Our aims were: (i) to describe electrocardiogram (ECG) characteristics of sinus rhythm (SR) and VT; (ii) to correlate SR with RBBB-VT ECGs; and (iii) to compare VT ECGs with electro-anatomic mapping (EAM) data.
METHODS AND RESULTS: From the European Survey on ACM, 70 patients with spontaneous RBBB-VT were included. Putative left ventricular (LV) sites of origin (SOOs) were estimated with a VT-axis-derived methodology and confirmed by EAM data when available.  Overall, 49 (70%) patients met definite Task Force Criteria. Low QRS voltage predominated in lateral leads (n = 37, 55%), but QRS fragmentation was more frequent in inferior leads (n = 15, 23%). T-wave inversion (TWI) was equally frequent in inferior (n = 28, 42%) and lateral (n = 27, 40%) leads. TWI in inferior leads was associated with reduced LV ejection fraction (LVEF; 46 ± 10 vs. 53 ± 8, P = 0.02). Regarding SOOs, the inferior wall harboured 31 (46%) SOOs, followed by the lateral wall (n = 17, 25%), the anterior wall (n = 15, 22%), and the septum (n = 4, 6%). EAM data were available for 16 patients and showed good concordance with the putative SOOs. In all patients with superior-axis RBBB-VT who underwent endo-epicardial VT activation mapping, VT originated from the LV.
CONCLUSIONS: In patients with ACM and RBBB-VT, RBBB-VTs originated mainly from the inferior and lateral LV walls. SR depolarization and repolarization abnormalities were frequent and associated with underlying variants
European Society of Cardiology Quality Indicators for the care and outcomes of cardiac pacing:developed by the Working Group for Cardiac Pacing Quality Indicators in collaboration with the European Heart Rhythm Association of the European Society of Cardiology
Aims: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. Methods and results: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. Conclusion: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers
Out-of-hospital cardiac arrest due to idiopathic ventricular fibrillation in patients with normal electrocardiograms:results from a multicentre long-term registry
AIMSâ: To define the clinical characteristics and long-term clinical outcomes of a large cohort of patients with idiopathic ventricular fibrillation (IVF) and normal 12-lead electrocardiograms (ECGs). METHODS AND RESULTS: Patients with ventricular fibrillation as the presenting rhythm, normal baseline, and follow-up ECGs with no signs of cardiac channelopathy including early repolarization or atrioventricular conduction abnormalities, and without structural heart disease were included in a registry. A total of 245 patients (median age: 38âyears; males 59%) were recruited from 25 centres. An implantable cardioverter-defibrillator (ICD) was implanted in 226 patients (92%), while 18 patients (8%) were treated with drug therapy only. Over a median follow-up of 63âmonths (interquartile range: 25-110âmonths), 12 patients died (5%); in four of them (1.6%) the lethal event was of cardiac origin. Patients treated with antiarrhythmic drugs only had a higher rate of cardiovascular death compared to patients who received an ICD (16% vs. 0.4%, Pâ=â0.001). Fifty-two patients (21%) experienced an arrhythmic recurrence. Age â€16âyears at the time of the first ventricular arrhythmia was the only predictor of arrhythmic recurrence on multivariable analysis [hazard ratio (HR) 0.41, 95% confidence interval (CI) 0.18-0.92; Pâ=â0.03]. CONCLUSIONâ: Patients with IVF and persistently normal ECGs frequently have arrhythmic recurrences, but a good prognosis when treated with an ICD. Children are a category of IVF patients at higher risk of arrhythmic recurrences
Thrombocytopenia and thrombocytosis are associated with different outcome in atrial fibrillation patients on anticoagulant therapy.
BACKGROUND:Information regarding the significance of platelet (PLT) count on outcome of atrial fibrillation (AF) patients who are treated with anticoagulants is limited. METHODS:We conducted a monocentric observational retrospective cohort study of AF patients treated with either warfarin (n = 6287) or non-vitamin K antagonist oral anticoagulants (NOACs) (n = 5240). Patient were divided into 3 subgroups; low, normal and high PLT for counts 450 K/ ÎŒl, respectively. A multivariate Cox-regression was used to evaluate the association between PLT subgroups and clinical outcomes. RESULTS:During follow-up [median = 40.6 months (IQR 17.6-60)], mortality (HR 1.36, 95 CI 1.1-1.74, p = 0.01) and rate of myocardial infarction (MI) (HR 2.4, 95 CI 1.28-4.57, p = 0.007) were higher in patients with high compared to normal PLT. Transient ischemic attack or cerebrovascular accident (TIA/CVA) rate was lower in patients with low compared to normal PLT (HR 0.69, 95 CI 0.51-0.93, p = 0.02). A comparison between NOACs and warfarin demonstrated a significantly better clinical outcome for patients on NOACs in both the low (lower mortality rates) and normal PLT subgroup (lower mortality, TIA/CVA and systemic emboli rates). For patients on NOACs, low and high compared to normal PLT were associated with a higher combined outcome (HR 1.12, 95 CI 1-1.38, p = 0.047), and a higher systemic emboli rate (HR 7.07, 95 CI 1.66-30.25, p = 0.008), respectively. CONCLUSIONS:Abnormal PLT count is associated with different clinical outcome of AF patients on anticoagulants. Further studies are needed in order assess whether PLT level should influence strategies of anticoagulation