96 research outputs found

    Continuous Tip Widening Technique for Roll-to-Roll Fabrication of Dry Adhesives

    Get PDF
    In this study, we reported continuous partial curing and tip-shaped modification methods for continuous production of dry adhesive with microscale mushroom-shaped structures. Typical fabrication methods of dry adhesive with mushroom-shaped structures are less productive due to the failure of large tips on pillar during demolding. To solve this problem, a typical pillar structure was fabricated through partial curing, and tip widening was realized through applying the proper pressure. Polyurethane acrylate was used in making the mushroom structure using two-step UV-assisted capillary force lithography (CFL). To make the mushroom structure, partial curing was performed on the micropillar, followed by tip widening. Dry adhesives with properties similar to those of typical mushroom-shaped dry adhesives were fabricated with reasonable adhesion force using the two-step UV-assisted CFL. This production technology was applied to the roll-to-roll process to improve productivity, thereby realizing continuous production without any defects. Such a technology is expected to be applied to various fields by achieving the productivity improvement of dry adhesives, which is essential for various applications

    Chemical Sharpening, Shortening, and Unzipping of Boron Nitride Nanotubes

    Get PDF
    Boron nitride nanotubes (BNNTs), the one-dimensional member of the boron nitride nanostructure family, are generally accepted to be highly inert to oxidative treatments and can only be covalently modifi ed by highly reactive species. Conversely, it is discovered that the BNNTs can be chemically dispersed and their morphology modifi ed by a relatively mild method: simply sonicating the nanotubes in aqueous ammonia solution. The dispersed nanotubes are significantly corroded, with end-caps removed, tips sharpened, and walls thinned. The sonication treatment in aqueous ammonia solution also removes amorphous BN impurities and shortened BNNTs, resembling various oxidative treatments of carbon nanotubes. Importantly, the majority of BNNTs are at least partially longitudinally cut, or "unzipped". Entangled and freestanding BN nanoribbons (BNNRs), resulting from the unzipping, are found to be approximately 5-20 nm in width and up to a few hundred nanometers in length. This is the fi rst chemical method to obtain BNNRs from BNNT unzipping. This method is not derived from known carbon nanotube unzipping strategies, but is unique to BNNTs because the use of aqueous ammonia solutions specifi cally targets the B-N bond network. This study may pave the way for convenient processing of BNNTs, previously thought to be highly inert, toward controlling their dispersion, purity, lengths, and electronic properties

    Two cases of female hydrocele of the canal of nuck

    Get PDF
    The processus vaginalis within the inguinal canal forms the canal of Nuck, which is a homolog of the processus vaginalis in women. Incomplete obliteration of the processus vaginalis causes indirect inguinal hernia or hydrocele of the canal of Nuck, a very rare condition in women. Here, we report 2 cases of hydrocele of the canal of Nuck that were diagnosed with ultrasonography in both cases and magnetic resonance imaging in 1 case to confirm the sonographic diagnosis. High ligation and hydrocelectomy were conducted in both patients. In 1 patient, 14 months later, the occurrence of contralateral inguinal hernia was suspected, but did not require surgery. The other patient had a history of surgery for left inguinal hernia 11 months before the occurrence of right hydrocele of the canal of Nuck. In both cases, the occurrence of an inguinal hernia on the contralateral side was noted

    Locally-applied 5-fluorouracil-loaded slow-release patch prevents pancreatic cancer growth in an orthotopic mouse model

    Get PDF
    To obtain improved efficacy against pancreatic cancer, we investigated the efficacy and safety of a locally-applied 5-fluorouracil (5-FU)-loaded polymeric patch on pancreatic tumors in an orthotopic nude-mouse model. The 5-FU-releasing polymeric patch was produced by 3D printing. After application of the patch, it released the drug slowly for 4 weeks, and suppressed BxPC-3 pancreas cancer growth. Luciferase imaging of BxPC3-Luc cells implanted in the pancreas was performed longitudinally. The drug patch delivered a 30.2 times higher level of 5-FU than an intra-peritoneal (i.p.) bolus injection on day-1. High 5-FU levels were accumulated within one week by the patch. Four groups were compared for efficacy of 5-FU. Drug-free patch as a negative control (Group I); 30% 5-FU-loaded patch (4.8 mg) (Group II); 5-FU i.p. once (4.8 mg) (Group III); 5-FU i.p. once a week (1.2 mg), three times (Group IV). The tumor growth rate was significantly faster in Group I than Group II, III, IV (p=0.047 at day-8, p=0.022 at day-12, p=0.002 at day-18 and p=0.034 at day-21). All mice in Group III died of drug toxicity within two weeks after injection. Group II showed more effective suppression of tumor growth than Group IV (p=0.018 at day-12 and p=0.017 at day-21). Histological analysis showed extensive apoptosis in the TUNEL assay and by Ki -67 staining. Western blotting confirmed strong expression of cleaved caspase-3 in Group II. No significant changes were found hematologically and histologically in the liver, kidney and spleen in Groups I, II, IV but were found in Group III.113Ysciescopu

    Continuous testing of silica-PEI adsorbents in a lab.-scale twin bubbling fluidized-bed system

    Get PDF
    In this study, a lab.-scale twin bubbling fluidized-bed system (TBS) has been used continuously to test the performance for CO2 adsorption of silica-PEI (S.PEI) adsorbents, containing 40 wt.% of PEI, which were supplied by the University of Nottingham (UNOTT). The TBS comprises bubbling-bed adsorption and desorption reactors, a riser for pneumatic conveying of solids from the adsorption to the desorption reactor, and a cyclone for solid-gas separation. The adsorbent prepared using PEI with a molecular mass of 800 (S.PEI-0.8K) was a preliminarily tested for almost 24 h at the given operating conditions by varying the inlet sorbent/CO2 mass ratio at the adsorber to analyse the CO2 removal efficiency in the adsorption reactor and the dynamic sorption capacity of the adsorbent. A 180-h continuous test was then carried out by changing various experimental conditions such as the H2O concentration, reaction temperature, solid layer height, reaction gas flow rate, and inlet sorbent/CO2 mass ratio at the adsorber using PEI with a molecular mass of 5000 (S.PEI-5K) adsorbent. In this test, a CO2 removal efficiency of above 80% and a dynamic sorption capacity greater than 6.0 wt.% were achieved

    Performance of a silica-polyethyleneimine adsorbent for post-combustion CO2 capture on a 100 kg scale in a fluidized bed continuous unit

    Get PDF
    © 2020 Elsevier B.V. Polyethyleneimine (PEI)/silica adsorbents have been considered as a promising candidate for post-combustion CO2 capture, but the limited process study has been performed on a pilot-scale unit. Herein we report the 150 h continuous test results using a 100 kg sample of silica-PEI on a fluidized bed continuous unit. The CO2 removal efficiency and dynamic sorption capacity were evaluated continuously by changing a number of variables. For the sorption reactor, the changing variables were inlet H2O concentrations of 0–8.3 vol%, inlet CO2 concentrations of 12.0–21.5 vol%, bed temperatures of 50–70 °C and the bed differential pressures of 176–370 mmH2O. For the desorption reactor operated at the bed temperature of 129–130 °C, inlet H2O concentrations of 8.0–13.5 vol%, inlet CO2 concentrations of 14.6–81.2 vol% and bed differential pressures of 430–580 mmH2O were used. During continuous operation, CO2 removal efficiencies of over 90% were achieved with dynamic sorption capacities of 7.5 wt%. Solid sample collected during continuous operation were analyzed by TGA and 13C NMR to identity the decrease of CO2 adsorption capacity and the extent of thermo-oxidative side reactions. Slow oxidative degradation of the silica-PEI occurred because the transporting adsorbent was exposure to the non-humidified air in the solid transport system

    Mutations in DDX58, which Encodes RIG-I, Cause Atypical Singleton-Merten Syndrome

    Get PDF
    Singleton-Merten syndrome (SMS) is an autosomal-dominant multi-system disorder characterized by dental dysplasia, aortic calcification, skeletal abnormalities, glaucoma, psoriasis, and other conditions. Despite an apparent autosomal-dominant pattern of inheritance, the genetic background of SMS and information about its phenotypic heterogeneity remain unknown. Recently, we found a family affected by glaucoma, aortic calcification, and skeletal abnormalities. Unlike subjects with classic SMS, affected individuals showed normal dentition, suggesting atypical SMS. To identify genetic causes of the disease, we performed exome sequencing in this family and identified a variant (c.1118A>C [p.Glu373Ala]) of DDX58, whose protein product is also known as RIG-I. Further analysis of DDX58 in 100 individuals with congenital glaucoma identified another variant (c.803G>T [p.Cys268Phe]) in a family who harbored neither dental anomalies nor aortic calcification but who suffered from glaucoma and skeletal abnormalities. Cys268 and Glu373 residues of DDX58 belong to ATP-binding motifs I and II, respectively, and these residues are predicted to be located closer to the ADP and RNA molecules than other nonpathogenic missense variants by protein structure analysis. Functional assays revealed that DDX58 alterations confer constitutive activation and thus lead to increased interferon (IFN) activity and IFN-stimulated gene expression. In addition, when we transduced primary human trabecular meshwork cells with c.803G>T (p.Cys268Phe) and c.1118A>C (p.Glu373Ala) mutants, cytopathic effects and a significant decrease in cell number were observed. Taken together, our results demonstrate that DDX58 mutations cause atypical SMS manifesting with variable expression of glaucoma, aortic calcification, and skeletal abnormalities without dental anomalies
    corecore