115 research outputs found

    Redundancy of stereoscopic images: Experimental Evaluation

    Full text link
    With the recent advancement in visualization devices over the last years, we are seeing a growing market for stereoscopic content. In order to convey 3D content by means of stereoscopic displays, one needs to transmit and display at least 2 points of view of the video content. This has profound implications on the resources required to transmit the content, as well as demands on the complexity of the visualization system. It is known that stereoscopic images are redundant, which may prove useful for compression and may have positive effect on the construction of the visualization device. In this paper we describe an experimental evaluation of data redundancy in color stereoscopic images. In the experiments with computer generated and real life and test stereo images, several observers visually tested the stereopsis threshold and accuracy of parallax measuring in anaglyphs and stereograms as functions of the blur degree of one of two stereo images and color saturation threshold in one of two stereo images for which full color 3D perception with no visible color degradations is maintained. The experiments support a theoretical estimate that one has to add, to data required to reproduce one of two stereoscopic images, only several percents of that amount of data in order to achieve stereoscopic perception

    Integration in the Fourier domain for restoration of a function from its slope : comparison of four methods

    Get PDF
    Altres ajuts: European Community project CTB556-01-4175.In some measurement techniques the profile, f(x), of a function should be obtained from the data on measured slope f'(x) by integration. The slope is measured in a given set of points, and from these data we should obtain the profile with the highest possible accuracy. Most frequently, the integration is carried out by numerical integration methods [Press et al., Numerical Recipes: The Art of Scientific Computing (Cambridge U. Press, Cambridge, 1987)] that assume different kinds of polynomial approximation of data between sampling points. We propose the integration of the function in the Fourier domain, by which the most-accurate interpolation is automatically carried out. Analysis of the integration methods in the Fourier domain permits us to easily study and compare the methods' behavior

    Real Time Turbulent Video Perfecting by Image Stabilization and Super-Resolution

    Full text link
    Image and video quality in Long Range Observation Systems (LOROS) suffer from atmospheric turbulence that causes small neighbourhoods in image frames to chaotically move in different directions and substantially hampers visual analysis of such image and video sequences. The paper presents a real-time algorithm for perfecting turbulence degraded videos by means of stabilization and resolution enhancement. The latter is achieved by exploiting the turbulent motion. The algorithm involves generation of a reference frame and estimation, for each incoming video frame, of a local image displacement map with respect to the reference frame; segmentation of the displacement map into two classes: stationary and moving objects and resolution enhancement of stationary objects, while preserving real motion. Experiments with synthetic and real-life sequences have shown that the enhanced videos, generated in real time, exhibit substantially better resolution and complete stabilization for stationary objects while retaining real motion.Comment: Submitted to The Seventh IASTED International Conference on Visualization, Imaging, and Image Processing (VIIP 2007) August, 2007 Palma de Mallorca, Spai

    Optics-less smart sensors and a possible mechanism of cutaneous vision in nature

    Full text link
    Optics-less cutaneous (skin) vision is not rare among living organisms, though its mechanisms and capabilities have not been thoroughly investigated. This paper demonstrates, using methods from statistical parameter estimation theory and numerical simulations, that an array of bare sensors with a natural cosine-law angular sensitivity arranged on a flat or curved surface has the ability to perform imaging tasks without any optics at all. The working principle of this type of optics-less sensor and the model developed here for determining sensor performance may be used to shed light upon possible mechanisms and capabilities of cutaneous vision in nature

    Color pattern recognition with circular component whitening

    Get PDF
    Polychromatic object recognition based on circular whitening preprocessing of red-green-blue components and multichannel matched filtering is described. Computer simulations and experimental results are provided to facilitate recognizing a color target among objects of similar shape but with different color contents. Experimental results are obtained with an optical correlator with two spatial light modulators, one to introduce the scene and the second one to introduce the filter

    Nonlocal similarity image filtering

    Get PDF
    Abstract. We exploit the recurrence of structures at different locations, orientations and scales in an image to perform denoising. While previous methods based on “nonlocal filtering ” identify corresponding patches only up to translations, we consider more general similarity transformations. Due to the additional computational burden, we break the problem down into two steps: First, we extract similarity invariant descriptors at each pixel location; second, we search for similar patches by matching descriptors. The descriptors used are inspired by scale-invariant feature transform (SIFT), whereas the similarity search is solved via the minimization of a cost function adapted from local denoising methods. Our method compares favorably with existing denoising algorithms as tested on several datasets.

    Transparent nanocrystalline yttria-stabilized-zirconia calvarium prosthesis

    Full text link
    UnlabelledLaser-based diagnostics and therapeutics show promise for many neurological disorders. However, the poor transparency of cranial bone (calvaria) limits the spatial resolution and interaction depth that can be achieved, thus constraining opportunity in this regard. Herein, we report preliminary results from efforts seeking to address this limitation through use of novel transparent cranial implants made from nanocrystalline yttria-stabilized zirconia (nc-YSZ). Using optical coherence tomography (OCT) imaging of underlying brain in an acute murine model, we show that signal strength is improved when imaging through nc-YSZ implants relative to native cranium. As such, this provides initial evidence supporting the feasibility of nc-YSZ as a transparent cranial implant material. Furthermore, it represents a crucial first step towards realization of an innovative new concept we are developing, which seeks to eventually provide a clinically-viable means for optically accessing the brain, on-demand, over large areas, and on a chronically-recurring basis, without need for repeated craniectomies.From the clinical editorIn this study, transparent nanocrystalline yttria-stabilized-zirconia is used as an experimental "cranium prosthesis" material, enabling the replacement of segments of cranial bone with a material that allows for optical access to the brain on a recurrent basis using optical imaging methods such as OCT
    corecore