12 research outputs found

    The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory

    Get PDF
    The Photodetector Array Camera and Spectrometer (PACS) is one of the three science instruments on ESA's far infrared and submillimetre observatory. It employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25 pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64 pixels, respectively, to perform integral-field spectroscopy and imaging photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m, over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in each band. In spectroscopy mode, it images a field of 47"x47", resolved into 5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral resolution of ~175km/s. We summarise the design of the instrument, describe observing modes, calibration, and data analysis methods, and present our current assessment of the in-orbit performance of the instrument based on the Performance Verification tests. PACS is fully operational, and the achieved performance is close to or better than the pre-launch predictions

    Case report: an unexpected link between partial deletion of the SHANK3 gene and Heller’s dementia infantilis, a rare subtype of autism spectrum disorder

    Get PDF
    International audienceAbstractBackgroundDeletions and mutations involving the SHANK3 gene lead to a nonspecific clinical presentation with moderate to profound intellectual disability, severely delayed or absent speech, and autism spectrum disorders (ASD).Better knowledge of the clinical spectrum of SHANK3 haploinsufficiency is useful to facilitate clinical care monitoring and to guide molecular diagnosis, essential for genetic counselling.Case presentationHere, we report a detailed clinical description of a 10-year-old girl carrying a pathogenic interstitial 22q13.3 deletion encompassing only the first 17 exons of SHANK3.The clinical features displayed by the girl strongly suggested the diagnosis of dementia infantilis, described by Heller in 1908, also known as childhood disintegrative disorder.ConclusionOur present case confirms several observations according to which regression may be part of the clinical phenotype of SHANK3 haploinsufficiency. Therefore, we think it is crucial to look for mutations in the gene SHANK3 in patients diagnosed for childhood disintegrative disorder or any developmental disorder with a regressive pattern involving social and communicative skills as well as cognitive and instinctual functions, with onset around 3 years

    A 4.2 K readout channel in a standard 0.7 μ\mum CMOS process for a photoconductor array camera

    No full text
    The cryogenic design of a cold CMOS readout channel to be used in the Photoconductor Array Camera and Spectrometer (PACS) aboard the Herschel Space Observatory (HSO, formerly called FIRST) [1], is presented. Robust architectures and optimized sizing reduce the effect of cryogenic anomalities on the circuit. Simulation results and tests, both at room temperature and 4 K show a non-linearity <<2%, a hysteresis of <5mV and noise < 100nV/Hz1/2^{1/2} @ 30Hz

    Demonstration of an 4.2 K analog switch matrix in a standard 0.7 μ\mu CMOS process

    No full text
    In this extended abstract a 4×44\times 4 Field Programmable Analogue Array or switch matrix is presented. Design and preliminary data will be discussed

    Comparison of the intermediate distance of a trifocal IOL with an extended depth-of-focus IOL:results of a prospective randomized trial

    Get PDF
    PURPOSE: To compare visual outcomes, reading ability, and visual quality between the Symfony extended depth-of-focus intraocular lens (IOL) and the trifocal AT LISA tri 839MP IOL. SETTING: University Eye Clinic Maastricht, The Netherlands. DESIGN: Prospective randomized controlled trial. METHODS: Patients were randomly assigned to bilateral Symfony IOL or AT LISA tri 839MP IOL implantation. The primary outcome measure was uncorrected intermediate visual acuity (UIVA measured at 66 cm). Secondary outcomes included uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), reading ability, and comparison of defocus curves, contrast sensitivity, optical adverse effects, and quality of vision. RESULTS: The study enrolled 60 eyes of 30 patients. The mean UIVA was -0.02 ± 0.03 (SD) vs 0.01 ± 0.03 logarithm of the minimal angle of resolution (logMAR) in the Symfony and AT LISA tri 839MP groups, respectively (P = .047). The UDVA was 0.01 ± 0.12 and -0.05 ± 0.07 logMAR (P = .11) and the UNVA was 0.09 ± 0.05 and 0.04 ± 0.07 logMAR (P = .052) in the Symfony and AT LISA tri 839MP groups, respectively. Reading ability was similar in both groups at 40 cm and 66 cm (P = .87 and P = .14, respectively). Less than 10% of patients in both groups experienced disabling glare. Patients experienced disabling halos in the AT LISA tri 839 MP group compared to the Symfony group in 39% and 21% of cases, respectively (P = .12). The mean score for visual functioning was 88.0 ± 14.1 n the trifocal group and 88.2 ± 10.9 for the EDOF group (P = .96). CONCLUSIONS: The UIVA was better in the Symfony group than in the AT LISA tri 839MP group. No significant differences were seen in the binocular UNVA and UDVA, contrast sensitivity, reading ability, incidence of photopic phenomena, and patient satisfaction
    corecore