1,470 research outputs found

    Origami lesion-targeting device for CT-guided interventions

    Get PDF
    The objective of this study is to preliminarily evaluate a lesion-targeting device for CT-guided interventions. The device is created by laser cutting the structure from a sheet of medical grade paperboard, 3D printing two radiocontrast agent grids onto the surface and folding the structure into a rectangular prism with a viewing window. An abdominal imaging phantom was used to evaluate the device through CT imaging and the targeting of lesions for needle insertion. The lesion-targeting trials resulted in a mean targeting error of 2.53 mm (SD 0.59 mm, n = 30). The device is rigid enough to adequately support standard biopsy needles, and it attaches to the patient, reducing the risk of tissue laceration by needles held rigidly in place by an external manipulator. Additional advantages include adequate support for the insertion of multiple surgical tools at once for procedures such as composite ablation and the potential to guide off-axial needle insertion. The low-cost and disposability of the device make it well-suited for the minimally invasive image-guided therapy environment

    3D printing endobronchial models for surgical training and simulation

    Get PDF
    Lung cancer is the leading cause of cancer-related deaths. Many methods and devices help acquire more accurate clinical and localization information during lung interventions and may impact the death rate for lung cancer. However, there is a learning curve for operating these tools due to the complex structure of the airway. In this study, we first discuss the creation of a lung phantom model from medical images, which is followed by a comparison of 3D printing in terms of quality and consistency. Two tests were conducted to test the performance of the developed phantom, which was designed for training simulations of the target and ablation processes in endochonchial interventions. The target test was conducted through an electromagnetic tracking catheter with navigation software. An ablation catheter with a recently developed thermochromic ablation gel conducted the ablation test. The results of two tests show that the phantom was very useful for target and ablation simulation. In addition, the thermochromic gel allowed doctors to visualize the ablation zone. Many lung interventions may benefit from custom training or accuracy with the proposed low-cost and patient-specific phantom

    In-situ Ti-6Al-4V/TiC composites synthesized by reactive spark plasma sintering : processing, microstructure, and dry sliding wear behaviour

    Get PDF
    Titanium carbide (TiC) reinforced Titanium Matrix Composites (TMCs) have been synthesized via an in-situ reactive spark plasma sintering (SPS) process using commercial Ti-6Al-4V spherical powders pre-coated with 1 wt% carbon nanoparticles by low-energy ball milling. Graphite flakes are used as carbon source, which aids powder flow during mixing as lubricant. Graphite transforms to nano-crystallite carbon during mixing which is favourable for the rapid formation of TiC second phase in the following SPS process. The composites exhibited a novel honeycomb-like cellular microstructure with the formation of 5–6 vol% fine TiC submicron grains interconnected in the titanium α/β matrix. In addition, the reinforcement of the TiC phase with a nano-hardness of 12.4 GPa, improves the wear resistance of the parent alloy matrix (5.1 GPa), with a reduction of 26–28% in wear rate during dry reciprocating sliding tests against Si3N4 balls. During sliding, the wear debris (predominantly anatase TiO2) builds up on the raised TiC hard phase forming a barrier layer of adhered oxide that can protect the alloy matrix underneath from abrasion and oxidation, leading to a reduced wear rate

    Argon plasma treatment techniques on steel and effects on diamond-like carbon structure and delamination

    Get PDF
    Copyright © 2011 Elsevier B.V. All rights reserved.We demonstrate alteration in diamond-like carbon (DLC) film structure, chemistry and adhesion on steel, related to variation in the argon plasma pretreatment stage of plasma enhanced chemical vapour deposition. We relate these changes to the alteration in substrate structure, crystallinity and chemistry due to application of an argon plasma process with negative self bias up to 600 V. Adhesion of the DLC film to the substrate was assessed by examination of the spallated fraction of the film following controlled deformation. Films with no pretreatment step immediately delaminated. At 300 V pretreatment, the spallated fraction is 8.2%, reducing to 1.2% at 450 V and 0.02% at 600V. For bias voltages below 450V the adhesion enhancement is explained by a reduction in carbon contamination on the substrate surface, from 59at.% with no treatment to 26at.% at 450V, concurrently with a decrease in the surface roughness, Rq, from 31.5nm to 18.9nm. With a pretreatment bias voltage of 600V a nanocrystalline, nanostructured surface is formed, related to removal of chromium and relaxation of stress; X-ray diffraction indicates this phase is incipient at 450V. In addition to improving film adhesion, the nanotexturing of the substrate prior to film deposition results in a DLC film that shows an increase in sp3/sp2 ratio from 1.2 to 1.5, a reduction in surface roughness from 31nm to 21nm, and DLC nodular asperities with reduced diameter and increased uniformity of size and arrangement. These findings are consistent with the substrate alterations due to the plasma pretreatment resulting in limitation of surface diffusion in the growth process. This suggests that in addition to deposition phase processes, the parameters of the pretreatment process need to be considered when designing diamond-like carbon coatings.This work is partially supported by the Technology Strategy Board, reference BD266E

    Graphene oxide functionalized long period fiber grating for highly sensitive hemoglobin detection

    Get PDF
    We present graphene oxide (GO) nanosheets functionalized long period grating (LPG) for ultrasensitive hemoglobin sensing. The sensing mechanism relies on the measurement of LPG resonant intensity change induced by the adsorption of hemoglobin molecules onto GO, where GO as a bio-interface linkage provides the significant light-matter interaction between evanescent field and target molecules. The deposition technique based on chemical-bonding associated with physical-adsorption was developed to immobilize GO nanosheets on cylindrical fiber device. The surface morphology was characterized by scanning electron microscope, atomic force microscopy, and Raman spectroscopy. With relatively thicker GO coating, the refractive index (RI) sensitivity of GO-LPG was extremely enhanced and achieved −76.5 dB/RIU, −234.2 dB/RIU and +1580.5 dB/RIU for RI region of 1.33-1.38, 1.40-1.44 and 1.45-1.46, respectively. The GO-LPG was subsequently implemented as an optical biosensor to detect human hemoglobin giving a sensitivity of 1.9 dB/(mg/mL) and a detectable concentration of 0.05 mg/mL, which was far below the hemoglobin threshold value for anemia defined by World Health Organization. The proposed GO-LPG architecture can be further developed as an optical biosensing platform for anemia diagnostics and biomedical applications

    Angle of repose and segregation in cohesive granular matter

    Full text link
    We study the effect of fluids on the angle of repose and the segregation of granular matter poured into a silo. The experiments are conducted in two regimes where: (i) the volume fraction of the fluid is small and it forms liquid bridges between particles, and (ii) the particles are completely immersed in the fluid. The data is obtained by imaging the pile formed inside a quasi-two dimensional silo through the transparent glass side walls. In the first series of experiments, the angle of repose is observed to increase sharply with the volume fraction of the fluid and then saturates at a value that depends on the size of the particles. We systematically study the effect of viscosity by using water-glycerol mixtures to vary it over at least three orders of magnitude while keeping the surface tension almost constant. Besides surface tension, the viscosity of the fluid is observed to have an effect on the angle of repose and the extent of segregation. In case of bidisperse particles, segregation is observed to decrease and finally saturate depending on the size ratio of the particles and the viscosity of the fluid. The sharp initial change and the subsequent saturation in the extent of segregation and angle of repose occurs over similar volume fraction of the fluid. In the second series of experiments, particles are poured into a container filled with a fluid. Although the angle of repose is observed to be unchanged, segregation is observed to decrease with an increase in the viscosity of the fluid.Comment: 9 pages, 12 figure

    Estrogen metabolism and mammographic density in postmenopausal women : a cross-sectional study

    Get PDF
    Background: Prospective studies have consistently found that postmenopausal breast cancer risk increases with circulating estrogens; however, findings from studies of estrogens and mammographic density (MD), an intermediate marker of breast cancer risk, have been inconsistent. We investigated the cross-sectional associations of urinary estrogens, and their 2-, 4-, and 16-hydroxylated metabolites with MD. Methods: Postmenopausal women without breast cancer (n = 194), ages 48 to 82 years, and reporting no current menopausal hormone therapy use were enrolled at a clinic in Western NY in 2005. Urinary estrogens and estrogen metabolites were measured using mass spectrometry. Percent MD and dense area (cm2) were measured using computer-assisted analyses of digitized films. Linear regression models were used to estimate associations of log-transformed estrogen measures with MD while adjusting for age, body mass index (BMI), parity, and past hormone therapy use. Results: Urinary concentrations of most individual estrogens and metabolites were not associated with MD; however, across the interdecile range of the ratio of parent estrogens (estrone and estradiol) to their metabolites, MD increased by 6.8 percentage points (P = 0.02) and dense area increased by 10.3 cm2 (P = 0.03). Across the interdecile ranges of the ratios of 2-, 4-, and 16-hydroxylation pathways to the parent estrogens, MD declined by 6.2 (P = 0.03), 6.4 (P = 0.04), and 5.7 (P = 0.05) percentage points, respectively. All associations remained apparent in models without adjustment for BMI. Conclusion: In this study of postmenopausal women, less extensive hydroxylation of parent estrogens was associated with higher MD. Impact: Hydroxylation of estrogens may modulate postmenopausal breast cancer risk through a pathway involving MD
    • …
    corecore