1,014 research outputs found

    Numerical simulation of mono-disperse droplet spray dryer under the influence of nozzle motion

    Full text link
    With the increasing demand of uniform particles in the fields of medicine etc., the research on monodisperse droplet spray dryer (MDSD) becomes important. The drying efficiency of the current MDSD facility has to be improved to realize industrial applications. In this work, the influence of several kinds of nozzle movement on the drying process has been thoroughly explored by silico experiments. It is found that the velocity of the nozzle movement plays a key role in drying efficiency improvement. The movement of the nozzle leads to a wider distribution of the final moisture content of particles, and this effect becomes less significant with the increase of the velocity of nozzle motion. For all motion types under investigation, the circular motion is superior to the other motion types. It is revealed that the change of droplet dispersion state due to nozzle motion is the main factor that improves drying performance

    The depth-profiled carrier concentration and scattering mechanism in undoped GaN film grown on sapphire

    Get PDF
    The carrier concentration and scattering mechanism in undoped GaN film grown on sapphire were investigated. The film was grown on sapphire using metal organic chemical vapor deposition (MOCVD). Confocal micro-Raman spectroscopic measurements and temperature-dependant Hall (TDH) measurements were performed for the study of the depth distribution of the carrier density across the GaN film. The existence of a nonuniform spatial distribution of free carriers in the film with a highly conductive layer of ∼1 μm thickness near the GaN sapphire boundary was confirmed from the study. The electron mobility limiting effect of nitrogen vacancies on GaN bulk film was also discussed.published_or_final_versio

    Ameliorative Effects of Neurolytic Celiac Plexus Block on Stress and Inflammation in Rats with Partial Hepatectomy

    Get PDF
    Purpose: To investigate effects of neurolytic celiac plexus block (NCPB) on stress and inflammation in rats with partial hepatectomy (PH).Methods: A model of PH rat was established, and serum C-reactive protein (CRP); corticosterone (GC); adrenocorticotropin (ACTH); noradrenaline (NA); adrenalin (AD); aspartate transaminase (AST); alanine transaminase (ALT); as well as tumor necrosis factor-α (TNF-α); interleukin (IL)-1β and IL-6; high mobility group box1 (HMGB1); and nitric oxide (NO) concentrations in serum assessed after PH. Additionally, Western blotting was performed to determine the effect of NCPB on expressions of glucocorticoid receptors (GR), inhibitor of nuclear factor kappa B (IκB), p65, c-Jun and inducible nitric oxide synthase (iNOS) of PH rats, as well as assay effects of NCPB on nuclear translocation of GR, c- Jun and p65. DNA binding activities of nuclear factor kappa B (NF-κB) and activator protein 1 (AP-1) were also determined.Results: NCPB reduced AST and ALT (P < 0.05), decreased secretion of inflammatory cytokines and NO (P < 0.05), as well as decreased CRP, GC, ACTH, NA and AD after PH (p < 0.05). NCPB increased expressions of GR and IκB, but expressions of p65, c-Jun, and iNOS (p < 0.05). Additionally, NCPB increased nuclear translocation of GR (p < 0.01), but decreased nuclear translocation of p65 and c-Jun after PH (p < 0.05). Additionally, DNA binding activity of NF-κB and AP-1 was decreased by NCPB (p < 0.05).Conclusion: The results indicate that NCPB treatment can significantly inhibit stress and inflammation in PH rats.Keywords: Neurolytic celiac plexus block, Cytokine, Nuclear translocation, Partial hepatectomy, Stress, Inflammatio

    Scalable Synthesis of Uniform Mesoporous Aluminosilicate Microspheres with Controllable Size and Morphology and High Hydrothermal Stability for Efficient Acid Catalysis

    Full text link
    Mesoporous aluminosilicates are promising solid acid catalysts. They are also excellent supports for transition metal catalysts for various catalytic applications. Synthesis of mesoporous aluminosilicates with controllable particle size, morphology, and structure, as well as adjustable acidity and high hydrothermal stability, is very desirable. In this work, we demonstrate the scalable synthesis of Al-SBA-15 microspheres with controllable physicochemical properties by using the microfluidic jet-spray-drying technology. The productivity is up to ∼30 g of dried particles per nozzle per hour. The Al-SBA-15 microspheres possess uniform controllable micron sizes (27.5-70.2 μm), variable surface morphologies, excellent hydrothermal stability (in pure steam at 800 °C), high surface areas (385-464 m2/g), ordered mesopore sizes (5.4-5.8 nm), and desirable acid properties. The dependence of various properties, including particle size, morphology, porosity, pore size, acidity, and hydrothermal stability, of the obtained Al-SBA-15 microspheres on experimental parameters including precursor composition (Si/Al ratio and solid content) and processing conditions (drying and calcination temperatures) is established. A unique morphology transition from smooth to wrinkled microsphere triggered by control of the Si/Al ratio and solid content is observed. The particle formation and morphology-evolution mechanism are discussed. The Al-SBA-15 microspheres exhibit high acid catalytic performance for aldol-condensation reaction between benzaldehyde and ethyl alcohol with a high benzaldehyde conversion (∼56.3%), a fast pseudo-first-order reaction rate (∼0.1344 h-1), and a high cyclic stability, superior to the commercial zeolite acid (H-ZSM-5). Several influencing factors on the catalytic performance of the obtained Al-SBA-15 microspheres are also studied

    Mucosal Application of gp140 Encoding DNA Polyplexes to Different Tissues Results in Altered Immunological Outcomes in Mice

    Get PDF
    Increasing evidence suggests that mucosally targeted vaccines will enhance local humoral and cellular responses whilst still eliciting systemic immunity. We therefore investigated the capacity of nasal, sublingual or vaginal delivery of DNA-PEI polyplexes to prime immune responses prior to mucosal protein boost vaccination. Using a plasmid expressing the model antigen HIV CN54gp140 we show that each of these mucosal surfaces were permissive for DNA priming and production of antigen-specific antibody responses. The elicitation of systemic immune responses using nasally delivered polyplexed DNA followed by recombinant protein boost vaccination was equivalent to a systemic prime-boost regimen, but the mucosally applied modality had the advantage in that significant levels of antigen-specific IgA were detected in vaginal mucosal secretions. Moreover, mucosal vaccination elicited both local and systemic antigen-specific IgG(+) and IgA(+) antibody secreting cells. Finally, using an Influenza challenge model we found that a nasal or sublingual, but not vaginal, DNA prime/protein boost regimen protected against infectious challenge. These data demonstrate that mucosally applied plasmid DNA complexed to PEI followed by a mucosal protein boost generates sufficient antigen-specific humoral antibody production to protect from mucosal viral challenge

    Neutrino-cooled accretion disks as the central engine of gamma-ray bursts

    Get PDF
    Neutrino-cooled hyperaccretion disks around stellar mass black holes are plausible candidates for the central engine of gamma-ray bursts. We calculate the one-dimensional structure and the annihilation luminosity of such disks. The resulting neutrino annihilation luminosity is still likely to be adequate for gamma-ray bursts, and it is ejected mainly from the inner region of the disk and has an anisotropic distribution

    Dual-gated bilayer graphene hot electron bolometer

    Full text link
    Detection of infrared light is central to diverse applications in security, medicine, astronomy, materials science, and biology. Often different materials and detection mechanisms are employed to optimize performance in different spectral ranges. Graphene is a unique material with strong, nearly frequency-independent light-matter interaction from far infrared to ultraviolet, with potential for broadband photonics applications. Moreover, graphene's small electron-phonon coupling suggests that hot-electron effects may be exploited at relatively high temperatures for fast and highly sensitive detectors in which light energy heats only the small-specific-heat electronic system. Here we demonstrate such a hot-electron bolometer using bilayer graphene that is dual-gated to create a tunable bandgap and electron-temperature-dependent conductivity. The measured large electron-phonon heat resistance is in good agreement with theoretical estimates in magnitude and temperature dependence, and enables our graphene bolometer operating at a temperature of 5 K to have a low noise equivalent power (33 fW/Hz1/2). We employ a pump-probe technique to directly measure the intrinsic speed of our device, >1 GHz at 10 K.Comment: 5 figure

    Evaluation of SLOG/TCI-III pediatric system on target control infusion of propofol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The target-controlled infusion-III (SLOG/TCI-III) system was derived from a model set up by the local pediatric population for target control infusion of propofol.</p> <p>Methods</p> <p>The current study aimed at evaluating the difference between target concentrations of propofol and performance, which was measured using the SLOG/TCI-III system in children. Thirty children fulfilling the I-II criteria according to American Society of Anesthesiology were enrolled in the study. The target plasma concentration of propofol was fed into the SLOG/TCI-III system and compared with the measured concentrations of propofol. Blood samples were collected and analyzed by high performance liquid chromatography with fluorescence detector. The performance error (PE) was determined for each measured blood propofol concentration. The performances of the TCI-III system were determined by the median performance error (MDPE), the median absolute performance error (MDAPE), and Wobble (the median absolute deviation of each PE from the MDPE), respectively.</p> <p>Results</p> <p>Concentration against target concentration showed good linear correlation: concentration = 1.3428 target concentration - 0.2633 (r = 0.8667). The MDPE and MDAPE of the pediatric system were 10 and 22%, respectively, and the median value for Wobble was 24%. MDPE and MDAPE were less than 15 and 30%, respectively.</p> <p>Conclusions</p> <p>The performance of TCI-III system seems to be in the accepted limits for clinical practice in children.</p

    Ionization Efficiency in the Dayside Martian Upper Atmosphere

    Get PDF
    Combining the Mars Atmosphere and Volatile Evolution measurements of neutral atmospheric density, solar EUV/X-ray flux, and differential photoelectron intensity made during 240 nominal orbits, we calculate the ionization efficiency, defined as the ratio of the secondary (photoelectron impact) ionization rate to the primary (photon impact) ionization rate, in the dayside Martian upper atmosphere under a range of solar illumination conditions. Both the CO₂ and O ionization efficiencies tend to be constant from 160 km up to 250 km, with respective median values of 0.19 ± 0.03 and 0.27 ± 0.04. These values are useful for fast calculation of the ionization rate in the dayside Martian upper atmosphere, without the need to construct photoelectron transport models. No substantial diurnal and solar cycle variations can be identified, except for a marginal trend of reduced ionization efficiency approaching the terminator. These observations are favorably interpreted by a simple scenario with ionization efficiencies, as a first approximation, determined by a comparison between relevant cross sections. Our analysis further reveals a connection between regions with strong crustal magnetic fields and regions with high ionization efficiencies, which are likely indicative of more efficient vertical transport of photoelectrons near magnetic anomalies
    • …
    corecore