2,201 research outputs found

    A study of low density, high strength high modulus filaments and composites

    Get PDF
    Filament and whisker reinforcement of low density, high strength, high modulus composites - metallic and ceramic layers alternated in multilaminar composite

    Development of dispersion strengthened chromium alloys Summary report

    Get PDF
    Dispersion strengthened chromium alloys with minimal quantities of interstitial impuritie

    Zirconia toughened SiC whisker reinforced alumina composites small business innovation research

    Get PDF
    The objective of this phase 1 project was to develop a ceramic composite with superior fracture toughness and high strength, based on combining two toughness inducing materials: zirconia for transformation toughening and SiC whiskers for reinforcement, in a controlled microstructure alumina matrix. The controlled matrix microstructure is obtained by controlling the nucleation frequency of the alumina gel with seeds (submicron alpha-alumina). The results demonstrate the technical feasibility of producing superior binary composites (Al2O3-ZrO2) and tertiary composites (Al2O3-ZrO2-SiC). Thirty-two composites were prepared, consolidated, and fracture toughness tested. Statistical analysis of the results showed that: (1) the SiC type is the key statistically significant factor for increased toughness; (2) sol-gel processing with a-alumina seed had a statistically significant effect on increasing toughness of the binary and tertiary composites compared to the corresponding mixed powder processing; and (3) ZrO2 content within the range investigated had a minor effect. Binary composites with an average critical fracture toughness of 6.6MPam sup 1/2, were obtained. Tertiary composites with critical fracture toughness in the range of 9.3 to 10.1 MPam sup 1/2 were obtained. Results indicate that these composites are superior to zirconia toughened alumina and SiC whisker reinforced alumina ceramic composites produced by conventional techniques with similar composition from published data

    Metabolic Physiology of Euthermic and Torpid Lesser Long-Eared Bats, Nyctophilus geoffroyi (Chiroptera: Vespertilionidae)

    Get PDF
    Thermal and metabolic physiology of the Australian lesser long-eared bat, Nyctophilias geojfroyi, a small (ca. 8 g) gleaning insectivore, was studied using flow-through respirometry. Basal metabolic rate of N. geojfroyi (1.42 ml O2 g−1 h−1) was 70% of that predicted for an 8-g mammal but fell within the range for vespertilionid bats. N. geoffroyi was thermally labile, like other vespertilionid bats from the temperate zone, with clear patterns of euthermy (body temperature >32°C) and torpor. It was torpid at temperatures ≤25°C, and spontaneously aroused from torpor at ambient temperatures ≥5°C. Torpor provided significant savings of energy and water, with substantially reduced rates of oxygen consumption and evaporative water loss. Minimum wet conductance (0.39 ml O2 g−1 h−1 °C−1) of euthermic bats was 108% of predicted, and euthermic dry conductance was 7.2 J g−1 h−1 °C−1 from 5-25°C. Minimum wet and dry conductances of bats that were torpid at an ambient temperature of 15-20°C (0.06 ml O2 g−1 h−1 °C−1 and 0.60 J g−1 h−1 °C−1) were substantially less than euthermic values, but conductance of some torpid bats increased at lower ambient temperatures and approached values for euthermic bats. Metabolic rates of bats torpid at ambient temperatures >10°C and bats euthermic in the thermoneutral zone indicated a metabolic Q10 of 3.9. That high Q10 suggested that there may have been an intrinsic reduction in metabolic rate during torpor, in addition to down-regulation of thermoregulation (which accounted for most of the reduction in metabolic rate) and the normal Q10 effec

    Generation of internal stress and its effects

    Get PDF
    Internal stresses may be generated continually in many polycrystalline materials. Their existence is manifested by changes in crystal defect concentration and arrangement, by surface observations, by macroscopic shape changes and particularly by alteration of mechanical properties when external stresses are simultaneously imposed

    Study of the stress intensity factors in the bulk of the material with synchrotron diffraction

    Get PDF
    Artículo de Proceedings de Congreso Internacional Fatigue2017In this work we present the results of a hybrid experimental and analytical approach for estimating the stress intensity factor. It uses the elastic strains within the bulk obtained by synchrotron X-ray diffraction data. The stress intensity factor is calculated using a multi-point overdeterministic method where the number of experimental data points is higher than the number of unknowns describing the elastic field surrounding the crack-tip. The tool is tested on X-ray strain measurements collected on a bainitic steel. In contrast to surface techniques the approach provides insights into the crack tip mechanics deep within the sample.Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech. The authors are grateful to the ESRF for ID15 beamtime awarded under MA-1483. Financial support of Universidad de Malaga through Plan Propio, Junta de Andalucía through Proyectos de Excelencia grant reference TEP-3244, Campus de Excelencia Internacional del Mar (CEIMAR) and Ministerio de Economia y Competitividad through grant reference MAT2016-76951-C2-2-P is also acknowledged. PJW acknowledges an ERC advanced grant

    Opportunities for Energy Conservation and Improved Comfort From Wind Washing Retrofits in Two-Story Homes - Part I

    Get PDF
    Wind washing is a general term referring to diminished thermal control caused by air movement over or through a thermal barrier. The primary focus of this paper is towards a specific type of wind washing where wind can push attic air into the floor cavity between first and second stories of the home through ineffective (or missing) air barriers separating attic space from the floor cavity. A second type of wind washing studied in this project involved insulation batts on knee walls where space between the batts and the wall board allowed air movement against the gypsum wall board. During hot weather, the first type of wind washing pushes hot air into the floor cavity (between the first and second stories) thereby heating ceiling, floor, and interior wall surfaces (see Figures 1 and 2). Condensation may occur on cold supply duct surfaces within the floor cavity resulting in ceiling moisture damage. In cold climates, cold air from wind washing can chill surfaces within the interior floor space and result in frozen water pipes. Through the summer of 2009, a field study tested thirty-two two-story homes and found significant wind washing potential in 40% of the homes. Part I of this paper will highlight the evaluation methods used and the extent of wind washing found in this study. Repairs and energy monitoring were completed in six of these homes to evaluate retrofit methods and cost effectiveness of retrofit solutions. These results are discussed in Part II of this paper.Florida Solar Energy Center, University of Central Florid

    Review of robust measurement of phosphorus in river water: sampling, storage, fractionation and sensitivity

    No full text
    International audienceThis paper reviews current knowledge on sampling, storage and analysis of phosphorus (P) in river waters. Potential sensitivity of rivers with different physical, chemical and biological characteristics (trophic status, turbidity, flow regime, matrix chemistry) is examined in terms of errors associated with sampling, sample preparation, storage, contamination, interference and analytical errors. Key issues identified include: The need to tailor analytical reagents and concentrations to take into account the characteristics of the sample matrix. The effects of matrix interference on the colorimetric analysis. The influence of variable rates of phospho-molybdenum blue colour formation. The differing responses of river waters to physical and chemical conditions of storage. The higher sensitivities of samples with low P concentrations to storage and analytical errors. Given high variability of river water characteristics in space and time, no single standardised methodology for sampling, storage and analysis of P in rivers can be offered. ?Good Practice' guidelines are suggested, which recommend that protocols for sampling, storage and analysis of river water for P is based on thorough site-specific method testing and assessment of P stability on storage. For wider sampling programmes at the regional/national scale where intensive site-specific method and stability testing are not feasible, ?Precautionary Practice' guidelines are suggested. The study highlights key areas requiring further investigation for improving methodological rigour. Keywords: phosphorus, orthophosphate, soluble reactive, particulate, colorimetry, stability, sensitivity, analytical error, storage, sampling, filtration, preservative, fractionation, digestio

    A systematic review and meta-analysis of the long-term effects of physical activity interventions on objectively measured outcomes

    Get PDF
    Abstract Background Although physical activity interventions are frequently reported to be effective, long-term changes are needed to generate meaningful health benefits. There are criticisms that evaluations of physical activity interventions mostly report short-term outcomes and that these are often self-reported rather than measured objectively. This study therefore aimed to assess the long-term (at least 24 month) effectiveness of behavioural interventions on objectively measured physical activity. Methods We conducted a systematic review with a meta-analysis of effects on objectively measured physical activity. We searched: Cochrane CENTRAL, EMBASE, PsychInfo, CINAHL and Pubmed up to 10th January 2022. Studies were included if they were in English and included a physical intervention that assessed physical activity in the long-term (defined as at least 24 months). Results Eight studies with 8480 participants were identified with data suitable for meta-analysis. There was a significant effect of interventions on daily steps 24 months post baseline (four studies, SMD: 0.15, 95% CI: 0.02 to 0.28) with similar results at 36 to 48 months of follow up (four studies, SMD: 0.17, 95% CI: 0.07 to 0.27). There was a significant effect of interventions on moderate-to-vigorous physical activity 24 months post baseline (four studies, SMD: 0.18 95% CI: 0.07 to 0.29) and at 36 to 48 months (three studies, SMD: 0.16 95% CI: 0.09 to 0.23). The mean effect size was small. However, the changes in moderate-to-vigorous physical activity and steps per day were clinically meaningful in the best-performing studies. Conclusion This review suggests that behavioural interventions can be effective in promoting small, but clinically meaningful increases in objectively measured physical activity for up to 48 months. There is therefore a need to develop interventions that can achieve greater increases in long-term physical activity with greater efficiency
    • …
    corecore