6 research outputs found

    Swedish operating room nurses preventive interventions to reduce bacterial growth, surgical site infections, and increase comfort in patients undergoing surgery

    No full text
    Surgical site infection is a major postoperative complication that causes patient suffering and is costly for society. The general aim of this thesis was to test and describe interventions performed by operating room (OR) nurses to prevent bacterial growth in surgical patients, with the intent to prevent surgical site infections (SSIs) whilst increase patients comfort. In studies I and II, 220 pacemaker patients were tested to compare pre-heated skin disinfection with room-temperature skin disinfection regard-ing bacterial growth, skin temperature and patient experience. Preheated skin disinfection was not less effective compared to room-temperature skin disinfection in reducing bacterial growth after skin disinfection and there were no differences regarding SSIs three month postoperatively. Preheated skin disinfection reduces skin heat loss and was perceived as more pleas-ant compared to room-temperature skin disinfection. In study III, 12 OR nurses were examined regarding bacterial growth on their hands and at the sterile glove cuff end after surgical hand disinfec-tion and again after wearing sterile surgical gloves during surgery. They were compared with a control group of 13 non-health care workers. OR nurses’ hands had higher amounts of bacterial growth at two of three culture sites after surgical hand disinfection compared with the control group, and the bacterial growth increased in both groups with time during surgery. There seems to be a risk of bacterial growth at the glove cuff end during surgery, involving the same type of bacteria as isolated from the hands. In study IV, 890 OR nurses answered an online questionnaire describ-ing OR nurses interventions guided by national guidelines to reduce SSIs, such as preparation of the patient skin, patient temperature, and OR ma-terials used. The proportion of the OR nurses who complied with the national guidelines preventive interventions was high: skin disinfection solution (93.5%), drapes (97.4%) and gowns (83.8%), and double gloves (73%). However, when guidelines were lacking the interventions differed

    Exploring bacterial growth and recolonization after preoperative hand disinfection and surgery between operating room nurses and non-health care workers: a pilot study

    No full text
    Abstract Background To prevent cross infection the surgical team perform preoperative hand disinfection before dressed in surgical gowns and gloves. Preoperative hand disinfection does not make hands sterile and the surgical glove cuff end has been regarded as a weak link, since it is not a liquid-proof interface. The aims were to investigate if there were differences in bacterial growth and recolonization of hands between operating room nurses and non-health care workers as well as to investigate if bacterial growth existed at the surgical glove cuff end during surgery. Methods This pilot project was conducted as an exploratory comparative clinical trial. Bacterial cultures were taken from the glove and gown interface and at three sites of the hands of 12 operating room nurses and 13 non-health care workers controls directly after preoperative hand disinfection and again after wearing surgical gloves and gowns. Colony forming units were analysed with Mann-Whitney U test and Wilcoxon Sign Ranks test comparing repeated measurements. Categorical variables were evaluated with chi-square test or Fisher’s exact test. Results Operating room nurses compared to non-health care workers had significant higher bacterial growth at two of three culture sites after surgical hand disinfection. Both groups had higher recolonization at one of the three culture sites after wearing surgical gloves. There were no differences between the groups in total colony forming units, that is, all sampling sites. Five out of 12 of the operating room nurses had bacterial growth at the glove cuff end and of those, four had the same bacteria at the glove cuff end as found in the cultures from the hands. Bacteria isolated from the glove cuff were P. acnes, S. warneri, S. epidermidis and Micrococcus species, the CFU/mL ranged from 10 to 40. Conclusions There were differences in bacterial growth and re-colonization between the groups but this was inconclusive. However, bacterial growth exists at the glove cuff and gown interface, further investigation in larger study is needed, to build on these promising, but preliminary, findings. Trial registration Trial registration was performed prospectively at Research web (FOU in Sweden, 117,971) 14/01/2013, and retrospectively at ClinicalTrials.gov (NCT02359708). 01/27/2015

    Swedish translation, cultural adaptation and psychometric evaluation of the pressure ulcer knowledge assessment tool for use in the operating room

    No full text
    The aim of this study was to psychometrically evaluate the Swedish operating room version of PUKAT 2.0. In total, 284 Swedish operating room nurses completed the survey of whom 50 completed the retest. The item difficulty P-value of 14 items ranged between 0.38 and 0.96 (median 0.65). Three items were found to be too easy (0.90-0.96). The D-value of 14 items ranged between 0.00 and 0.42 (median 0.46). Three items had a D-value lower than 0.20 (0.11-0.16) and eight items scored higher than 0.40 (0.45-0.61). The quality of the response alternatives (a-value) ranged between 0.00 and 0.42. This showed that nurses with a master's degree had a higher knowledge than nurses with a professional degree (respectively 9.4/14 versus 8.6/14; t = -2.4, df = 199, P = 0.02). The ICC was 0.65 (95% CI 0.45-0.78). The ICCs for the domains varied from 0.12 (95% CI = -0.16-0.39) to 0.59 (95% CI = 0.38-0.75). Results indicated that 11 of the original items contributed to the overall validity. However, the low participation in the test-retest made the reliability of the instrument low. An extended evaluation with a larger sample should be considered in order to confirm aspects of the psychometric properties of this instrument

    The Swedish version of the attitude towards pressure ulcer prevention instrument for use in an operating room context (APUP-OR) : A nationwide psychometric evaluation

    No full text
    Introduction: To assess operating room (OR) nurses' attitudes towards pressure ulcer prevention, the Attitude towards Pressure Ulcer Prevention (APuP) instrument was developed. Aim: The aim of this study was to psychometrically evaluate the Attitude towards Pressure Ulcer Prevention (APuP) instrument in a Swedish OR context. Materials and methods: A psychometric evaluation study was conducted, using a convenience sample, between February and August 2020. Validity (content, construct, discriminatory power) and reliability (stability and internal consistency) were evaluated. Results: The first survey (test) was completed by 284 Swedish OR nurses, of whom n = 50 (17.6%) completed the second survey (retest). A Principal Component Analysis was conducted for the 13-item instrument. The KMO value for this model was 0.62. Bartlett's test for sphericity was statistically significant (p 0.001). Five factors were identified which accounted for 56% of the variance in responses related to attitudes toward pressure ulcer prevention. The Cronbach's a for the instrument "attitude towards Pressure Ulcer Prevention" was 0.66. The intraclass correlation coefficient was 0.49 (95% CI = 0.25-0.67). Conclusion: This Swedish version of the APuP- OR is the first step in the development of an instrument to measure OR nurses' attitudes towards PU prevention in a Swedish OR context. The reliability of the instrument was low and the validity moderate. A larger sample and the revision or addition of items related to the context of the operating room should be considered in order to confirm aspects of the psychometric properties

    Long-term effects of restriction of intravenous fluid in adult ICU patients with septic shock

    Get PDF
    PURPOSE To assess long-term outcomes of restrictive versus standard intravenous (IV) fluid therapy in adult intensive care unit (ICU) patients with septic shock included in the European Conservative versus Liberal Approach to Fluid Therapy in Septic Shock in Intensive Care (CLASSIC) trial. METHODS We conducted the pre-planned analyses of mortality, health-related quality of life (HRQoL) using EuroQol (EQ)-5D-5L index values and EQ visual analogue scale (VAS), and cognitive function using Mini Montreal Cognitive Assessment (Mini MoCA) test at 1 year. Deceased patients were assigned numerical zero for HRQoL as a state equal to death and zero for cognitive function outcomes as worst possible score, and we used multiple imputation for missing data on HRQoL and cognitive function. RESULTS Among 1554 randomized patients, we obtained 1-year data on mortality in 97.9% of patients, HRQoL in 91.3%, and cognitive function in 86.3%. One-year mortality was 385/746 (51.3%) in the restrictive-fluid group versus 383/767 (49.9%) in the standard-fluid group, absolute risk difference 1.5%-points [99% confidence interval (CI) - 4.8 to 7.8]. Mean differences were 0.00 (99% CI - 0.06 to 0.05) for EQ-5D-5L index values, - 0.65 for EQ VAS (- 5.40 to 4.08), and - 0.14 for Mini MoCA (- 1.59 to 1.14) for the restrictive-fluid group versus the standard-fluid group. The results for survivors only were similar in both groups. CONCLUSIONS Among adult ICU patients with septic shock, restrictive versus standard IV fluid therapy resulted in similar survival, HRQoL, and cognitive function at 1 year, but clinically important differences could not be ruled out
    corecore