69 research outputs found

    Identification and mapping real-world data sources for heart failure, acute coronary syndrome, and atrial fibrillation

    Get PDF
    BACKGROUND: Transparent and robust real-world evidence sources are increasingly important for global health, including cardiovascular diseases. We aimed to identify global real-world data (RWD) sources for heart failure (HF), acute coronary syndrome (ACS), and atrial fibrillation (AF). METHODS: We conducted a systematic review of publications with RWD pertaining to HF, ACS, and AF (2010-2018), generating a list of unique data sources. Metadata were extracted based on the source type (e.g. electronic health records, genomics, clinical data), study design, population size, clinical characteristics, follow-up duration, outcomes, and assessment of data availability for future studies and linkage. RESULTS: Overall, 11,889 publications were retrieved for HF, 10,729 for ACS, and 6,262 for AF. From these, 322 (HF), 287 (ACS), and 220 (AF) data sources were selected for detailed review. Majority of data sources had near complete data on demographic variables (HF: 94%, ACS: 99%, and AF: 100%) and considerable data on comorbidities (HF: 77%, ACS: 93%, and AF: 97%). The least reported data categories were drug codes (HF, ACS, and AF: 10%) and caregiver involvement (HF: 6%, ACS: 1%, and AF: 1%). Only a minority of data sources provided information on access to data for other researchers (11%) or whether data could be linked to other data sources to maximize clinical impact (20%). The list and metadata for the RWD sources are publicly available at www.escardio.org/bigdata. CONCLUSIONS: This review has created a comprehensive resource of cardiovascular data sources, providing new avenues to improve future real-world research and to achieve better patient outcomes

    Consistent imprints of elevation, soil temperature and moisture on plant and arthropod communities across two subarctic landscapes

    Get PDF
    1. Factors shaping arthropod and plant community structure at fine spatial scales are poorly understood. This includes microclimate, which likely plays a large role in shaping local community patterns, especially in heterogeneous landscapes characterised by high microclimatic variability in space and in time.2. We explored differences in local microclimatic conditions and regional species pools in two subarctic regions: Kilpisj & auml;rvi in north-west Finland and Varanger in north-east Norway. We then investigated the relationship between fine-scale climatic variation and local community characteristics (species richness and abundance) among plants and arthropods, differentiating the latter into two groups: flying and ground-dwelling arthropods collected by Malaise and pitfall traps, respectively. Arthropod taxa were identified through DNA metabarcoding. Finally, we examined if plant richness can be used to predict patterns in arthropod communities.3. Variation in soil temperature, moisture and snow depth proved similar between regions, despite differences in absolute elevation. For each group of organisms, we found that about half of the species were shared between Kilpisj & auml;rvi and Varanger, with a quarter unique to each region.4. Plants and arthropods responded largely to the same drivers. The richness and abun-dance of both groups decreased as elevation increased and were positively correlated with higher soil moisture and temperature values. Plant species richness was a poor predictor of local arthropod richness, in particular for ground-dwelling arthropods.5. Our results reveal how microclimatic variation within each region carves pro-nounced, yet consistent patterns in local community richness and abundance out of a joint species pool

    Cross-oncopanel study reveals high sensitivity and accuracy with overall analytical performance depending on genomic regions

    Get PDF
    BackgroundTargeted sequencing using oncopanels requires comprehensive assessments of accuracy and detection sensitivity to ensure analytical validity. By employing reference materials characterized by the U.S. Food and Drug Administration-led SEquence Quality Control project phase2 (SEQC2) effort, we perform a cross-platform multi-lab evaluation of eight Pan-Cancer panels to assess best practices for oncopanel sequencing.ResultsAll panels demonstrate high sensitivity across targeted high-confidence coding regions and variant types for the variants previously verified to have variant allele frequency (VAF) in the 5-20% range. Sensitivity is reduced by utilizing VAF thresholds due to inherent variability in VAF measurements. Enforcing a VAF threshold for reporting has a positive impact on reducing false positive calls. Importantly, the false positive rate is found to be significantly higher outside the high-confidence coding regions, resulting in lower reproducibility. Thus, region restriction and VAF thresholds lead to low relative technical variability in estimating promising biomarkers and tumor mutational burden.ConclusionThis comprehensive study provides actionable guidelines for oncopanel sequencing and clear evidence that supports a simplified approach to assess the analytical performance of oncopanels. It will facilitate the rapid implementation, validation, and quality control of oncopanels in clinical use.Peer reviewe

    Tumour-infiltrating CD8+ lymphocytes and colorectal cancer recurrence by tumour and nodal stage

    Get PDF
    Background Intratumoural T-cell infiltrate intensity cortes wrelaith clinical outcome in stage II/III colorectal cancer (CRC). We aimed to determine whether this association varies across this heterogeneous group. Methods We performed a pooled analysis of 1804 CRCs from the QUASAR2 and VICTOR trials. Intratumoural CD8+ and CD3+ densities were quantified by immunohistochemistry in tissue microarray (TMA) cores, and their association with clinical outcome analysed by Cox regression. We validated our results using publicly available gene expression data in a pooled analysis of 1375 CRCs from seven independent series. Results In QUASAR2, intratumoural CD8+ was a stronger predictor of CRC recurrence than CD3+ and showed similar discriminative ability to both markers in combination. Pooled multivariable analysis of both trials showed increasing CD8+ density was associated with reduced recurrence risk independent of confounders including DNA mismatch repair deficiency, POLE mutation and chromosomal instability (multivariable hazard ratio [HR] for each two-fold increase = 0.92, 95%CI = 0.87–0.97, P = 3.6 × 10−3). This association was not uniform across risk strata defined by tumour and nodal stage: absent in low-risk (pT3,N0) cases (HR = 1.03, 95%CI = 0.87–1.21, P = 0.75), modest in intermediate-risk (pT4,N0 or pT1-3,N1-2) cases (HR = 0.92, 95%CI = 0.86–1.0, P = 0.046) and strong in high-risk (pT4,N1-2) cases (HR = 0.87, 95%CI = 0.79–0.97, P = 9.4 × 10−3); PINTERACTION = 0.090. Analysis of tumour CD8A expression in the independent validation cohort revealed similar variation in prognostic value across risk strata (PINTERACTION = 0.048). Conclusions The prognostic value of intratumoural CD8+ cell infiltration in stage II/III CRC varies across tumour and nodal risk strata. </p

    Phase 3, Randomized, 20-Month Study of the Efficacy and Safety of Bimatoprost Implant in Patients with Open-Angle Glaucoma and Ocular Hypertension (ARTEMIS 2)

    Get PDF
    Objective- To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of 10 and 15 µg bimatoprost implant in patients with open-angle glaucoma (OAG) or ocular hypertension (OHT). Methods- This randomized, 20-month, multicenter, masked, parallel-group, phase 3 trial enrolled 528 patients with OAG or OHT and an open iridocorneal angle inferiorly in the study eye. Study eyes were administered 10 or 15 µg bimatoprost implant on day 1, week 16, and week 32, or twice-daily topical timolol maleate 0.5%. Primary endpoints were IOP and IOP change from baseline through week 12. Safety measures included treatment-emergent adverse events (TEAEs) and corneal endothelial cell density (CECD). Results- Both 10 and 15 µg bimatoprost implant met the primary endpoint of noninferiority to timolol in IOP lowering through 12 weeks. Mean IOP reductions from baseline ranged from 6.2–7.4, 6.5–7.8, and 6.1–6.7 mmHg through week 12 in the 10 µg implant, 15 µg implant, and timolol groups, respectively. IOP lowering was similar after the second and third implant administrations. Probabilities of requiring no IOP-lowering treatment for 1 year after the third administration were 77.5% (10 µg implant) and 79.0% (15 µg implant). The most common TEAE was conjunctival hyperemia, typically temporally associated with the administration procedure. Corneal TEAEs of interest (primarily corneal endothelial cell loss, corneal edema, and corneal touch) were more frequent with the 15 than the 10 µg implant and generally were reported after repeated administrations. Loss in mean CECD from baseline to month 20 was ~ 5% in 10 µg implant-treated eyes and ~ 1% in topical timolol-treated eyes. Visual field progression (change in the mean deviation from baseline) was reduced in the 10 µg implant group compared with the timolol group. Conclusions- The results corroborated the previous phase 3 study of the bimatoprost implant. The bimatoprost implant met the primary endpoint and effectively lowered IOP. The majority of patients required no additional treatment for 12 months after the third administration. The benefit-risk assessment favored the 10 over the 15 µg implant. Studies evaluating other administration regimens with reduced risk of corneal events are ongoing. The bimatoprost implant has the potential to improve adherence and reduce treatment burden in glaucoma
    • …
    corecore