1,727 research outputs found

    Genomic characterization of Gli-activator targets in sonic hedgehog-mediated neural patterning

    Get PDF
    Sonic hedgehog (Shh) acts as a morphogen to mediate the specification of distinct cell identities in the ventral neural tube through a Gli-mediated (Gli1-3) transcriptional network. Identifying Gli targets in a systematic fashion is central to the understanding of the action of Shh. We examined this issue in differentiating neural progenitors in mouse. An epitope-tagged Gli-activator protein was used to directly isolate cis-regulatory sequences by chromatin immunoprecipitation (ChIP). ChIP products were then used to screen custom genomic tiling arrays of putative Hedgehog (Hh) targets predicted from transcriptional profiling studies, surveying 50-150 kb of non-transcribed sequence for each candidate. In addition to identifying expected Gli-target sites, the data predicted a number of unreported direct targets of Shh action. Transgenic analysis of binding regions in Nkx2.2, Nkx2.1 (Titf1) and Rab34 established these as direct Hh targets. These data also facilitated the generation of an algorithm that improved in silico predictions of Hh target genes. Together, these approaches provide significant new insights into both tissue-specific and general transcriptional targets in a crucial Shh-mediated patterning process

    Characterization of aldehyde dehydrogenase isozymes in ovarian cancer tissues and sphere cultures

    Get PDF
    BACKGROUND: Aldehyde dehydrogenases belong to a superfamily of detoxifying enzymes that protect cells from carcinogenic aldehydes. Of the superfamily, ALDH1A1 has gained most attention because current studies have shown that its expression is associated with human cancer stem cells. However, ALDH1A1 is only one of the 19 human ALDH subfamilies currently known. The purpose of the present study was to determine if the expression and activities of other major ALDH isozymes are associated with human ovarian cancer and ovarian cancer sphere cultures. METHODS: Immunohistochemistry was used to delineate ALDH isozyme localization in clinical ovarian tissues. Western Blot analyses were performed on lysates prepared from cancer cell lines and ovarian cancer spheres to confirm the immunohistochemistry findings. Quantitative reverse transcription-polymerase chain reactions were used to measure the mRNA expression levels. The Aldefluor® assay was used to measure ALDH activity in cancer cells from the four tumor subtypes. RESULTS: Immunohistochemical staining showed significant overexpression of ALDH1A3, ALDH3A2, and ALDH7A1 isozymes in ovarian tumors relative to normal ovarian tissues. The expression and activity of ALDH1A1 is tumor type-dependent, as seen from immunohistochemisty, Western blot analysis, and the Aldefluor® assay. The expression was elevated in the mucinous and endometrioid ovarian epithelial tumors than in serous and clear cell tumors. In some serous and most clear cell tumors, ALDH1A1 expression was found in the stromal fibroblasts. RNA expression of all studied ALDH isozymes also showed higher expression in endometrioid and mucinous tumors than in the serous and clear cell subtypes. The expression of ALDH enzymes showed tumor type-dependent induction in ovarian cancer cells growing as sphere suspensions in serum-free medium. CONCLUSIONS: The results of our study indicate that ALDH enzyme expression and activity may be associated with specific cell types in ovarian tumor tissues and vary according to cell states. Elucidating the function of the ALDH isozymes in lineage differentiation and pathogenesis may have significant implications for ovarian cancer pathophysiology

    Coating Thin Mirror Segments for Lightweight X-ray Optics

    Get PDF
    Next generations lightweight, high resolution, high throughput optics for x-ray astronomy requires integration of very thin mirror segments into a lightweight telescope housing without distortion. Thin glass substrates with linear dimension of 200 mm and thickness as small as 0.4 mm can now be fabricated to a precision of a few arc-seconds for grazing incidence optics. Subsequent implementation requires a distortion-free deposition of metals such as iridium or platinum. These depositions, however, generally have high coating stresses that cause mirror distortion. In this paper, we discuss the coating stress on these thin glass mirrors and the effort to eliminate their induced distortion. It is shown that balancing the coating distortion either by coating films with tensile and compressive stresses, or on both sides of the mirrors is not sufficient. Heating the mirror in a moderately high temperature turns out to relax the coated films reasonably well to a precision of about a second of arc and therefore provide a practical solution to the coating problem

    Prescription and Other Medication Use in Pregnancy

    Get PDF
    OBJECTIVE: To characterize prescription and other medication use in a geographically and ethnically diverse cohort of women in their first pregnancy. METHODS: In a prospective, longitudinal cohort study of nulliparous women followed through pregnancy from the first trimester, medication use was chronicled longitudinally throughout pregnancy. Structured questions and aids were used to capture all medications taken as well as reasons they were taken. Total counts of all medications taken including number in each category and class were captured. Additionally, reasons the medications were taken were recorded. Trends in medications taken across pregnancy and in the first trimester were determined. RESULTS: Of the 9,546 study participants, 9,272 (97.1%) women took at least one medication during pregnancy with 9,139 (95.7%) taking a medication in the first trimester. Polypharmacy, defined as taking at least five medications, occurred in 2,915 (30.5%) women. Excluding vitamins, supplements, and vaccines, 73.4% of women took a medication during pregnancy with 55.1% taking one in the first trimester. The categories of drugs taken in pregnancy and in the first trimester include the following: gastrointestinal or antiemetic agents (34.3%, 19.5%), antibiotics (25.5%, 12.6%), and analgesics (23.7%, 15.6%, which includes 3.6%; 1.4% taking an opioid pain medication). CONCLUSION: In this geographically and ethnically diverse cohort of nulliparous pregnant women, medication use was nearly universal and polypharmacy was common

    Precise Alignment and Permanent Mounting of Thin and Lightweight X-ray Segments

    Get PDF
    To provide observations to support current research efforts in high energy astrophysics. future X-ray telescope designs must provide matching or better angular resolution while significantly increasing the total collecting area. In such a design the permanent mounting of thin and lightweight segments is critical to the overall performance of the complete X-ray optic assembly. The thin and lightweight segments used in the assemhly of the modules are desigued to maintain and/or exceed the resolution of existing X-ray telescopes while providing a substantial increase in collecting area. Such thin and delicate X-ray segments are easily distorted and yet must be aligned to the arcsecond level and retain accurate alignment for many years. The Next Generation X-ray Optic (NGXO) group at NASA Goddard Space Flight Center has designed, assembled. and implemented new hardware and procedures mth the short term goal of aligning three pairs of X-ray segments in a technology demonstration module while maintaining 10 arcsec alignment through environmental testing as part of the eventual design and construction of a full sized module capable of housing hundreds of X-ray segments. The recent attempts at multiple segment pair alignment and permanent mounting is described along with an overview of the procedure used. A look into what the next year mll bring for the alignment and permanent segment mounting effort illustrates some of the challenges left to overcome before an attempt to populate a full sized module can begin

    Sleep During Pregnancy: The nuMoM2b Pregnancy and Sleep Duration and Continuity Study

    Get PDF
    Study Objectives: To characterize sleep duration, timing and continuity measures in pregnancy and their association with key demographic variables. Methods: Multisite prospective cohort study. Women enrolled in the nuMoM2b study (nulliparous women with a singleton gestation) were recruited at the second study visit (16-21 weeks of gestation) to participate in the Sleep Duration and Continuity substudy. Women <18 years of age or with pregestational diabetes or chronic hypertension were excluded from participation. Women wore a wrist activity monitor and completed a sleep log for 7 consecutive days. Time in bed, sleep duration, fragmentation index, sleep efficiency, wake after sleep onset, and sleep midpoint were averaged across valid primary sleep periods for each participant. Results: Valid data were available from 782 women with mean age of 27.3 (5.5) years. Median sleep duration was 7.4 hours. Approximately 27.9% of women had a sleep duration of 9 hours. In multivariable models including age, race/ethnicity, body mass index, insurance status, and recent smoking history, sleep duration was significantly associated with race/ethnicity and insurance status, while time in bed was only associated with insurance status. Sleep continuity measures and sleep midpoint were significantly associated with all covariates in the model, with the exception of age for fragmentation index and smoking for wake after sleep onset. Conclusions: Our results demonstrate the relationship between sleep and important demographic characteristics during pregnancy

    Astronomical X-Ray Optics Using Mono-Crystalline Silicon: High Resolution, Light Weight, and Low Cost

    Get PDF
    X-ray astronomy critically depends on X-ray optics. The capability of an X-ray telescope is largelydetermined by the point-spread function (PSF) and the photon-collection area of its mirrors, the same astelescopes in other wavelength bands. Since an X-ray telescope must be operated above the atmosphere inspace and that X-rays reflect only at grazing incidence, X-ray mirrors must be both lightweight and thin, bothof which add significant technical and engineering challenge to making an X-ray telescope. In this paper wereport our effort at NASA Goddard Space Flight Center (GSFC) of developing an approach to making an Xraymirror assembly that can be significantly better than the mirror assembly currently flying on the ChandraX-ray Observatory in each of the three aspects: PSF, effective area per unit mass, and production cost per uniteffective area. Our approach is based on the precision polishing of mono-crystalline silicon to fabricate thinand lightweight X-ray mirrors of the highest figure quality and micro-roughness, therefore, having thepotential of achieving diffraction-limited X-ray optics. When successfully developed, this approach will makeimplementable in the 2020s and 2030s many X-ray astronomical missions that are currently on the drawingboard, including sounding rocket flights such as OGRE, Explorer class missions such as STAR-X andFORCE, Probe class missions such as AXIS, TAP, and HEX-P, as well as large missions such as Lynx

    Kinematic Alignment and Bonding of Silicon Mirrors for High-Resolution Astronomical X-Ray Optics

    Get PDF
    Optics for the next generation's high-resolution, high throughput x-ray telescope requires fabrication of well-formed lightweight mirror segments and their integration at arc-second precision. Recent advances in the fabrication of silicon mirrors developed at NASA/Goddard prompted us to develop a new method of mirror alignment and integration. In this method, stiff silicon mirrors are aligned quasi-kinematically and are bonded in an interlocking fashion to produce a "meta-shell" with large collective area. We address issues of aligning and bonding mirrors with this method and show a recent result of 4 seconds-of-arc for a single pair of mirrors tested at soft x-rays

    Acquisition of pneumococci specific effector and regulatory Cd4+ T cells localising within human upper respiratory-tract mucosal lymphoid tissue

    Get PDF
    The upper respiratory tract mucosa is the location for commensal Streptococcus (S.) pneumoniae colonization and therefore represents a major site of contact between host and bacteria. The CD4(+) T cell response to pneumococcus is increasingly recognised as an important mediator of immunity that protects against invasive disease, with data suggesting a critical role for Th17 cells in mucosal clearance. By assessing CD4 T cell proliferative responses we demonstrate age-related sequestration of Th1 and Th17 CD4(+) T cells reactive to pneumococcal protein antigens within mucosal lymphoid tissue. CD25(hi) T cell depletion and utilisation of pneumococcal specific MHCII tetramers revealed the presence of antigen specific Tregs that utilised CTLA-4 and PDL-1 surface molecules to suppress these responses. The balance between mucosal effector and regulatory CD4(+) T cell immunity is likely to be critical to pneumococcal commensalism and the prevention of unwanted pathology associated with carriage. However, if dysregulated, such responses may render the host more susceptible to invasive pneumococcal infection and adversely affect the successful implementation of both polysaccharide-conjugate and novel protein-based pneumococcal vaccines

    Comparison and correlates of three preference-based healthrelated quality-of-life measures among overweight and obese women with urinary incontinence

    Full text link
    PURPOSE: To compare three preference-based health-related quality-of-life (HRQL) measures and examine independent correlates of HRQL among overweight and obese women with urinary incontinence (UI) enrolled in a weight loss intervention trial. METHODS: Participants completed baseline questionnaires, which included the Health Utilities Index 3 (HUI3) and Medical Outcomes Study Short Form-36 (SF-36). The SF-36 was used to derive SF-6D and estimated Quality of Well-Being (eQWB) scores. Height, weight, medical history, incontinence measures, and level of physical activity also were assessed. The intraclass correlation coefficient (ICC) was computed, and differences in mean scores across HRQL measures were examined. Potential correlates of HUI3, SF-6D, and eQWB scores were evaluated using multivariable generalized linear models. RESULTS: Mean ± SD scores for the HUI3, SF-6D, and eQWB were 0.81 ± 0.18, 0.75 ± 0.10, and 0.71 ± 0.06, respectively. Significant differences were observed across measures (P \u3c 0.0001), and the overall ICC was 0.36. In multivariable analyses, BMI was negatively associated with HUI3 (P = 0.003) and eQWB (P \u3c 0.001), and UI episode frequency was negatively associated with eQWB (P = 0.015) and SF-6D (P \u3c 0.001). CONCLUSIONS: Significant differences in mean utilities across the HUI3, SF-6D, and eQWB indicate that these measures do not assess identical dimensions of HRQL. Both BMI and UI episode frequency were related to HRQL in this cohort; however, the magnitude of the relationship depended on the preference-based measure used. These findings highlight the need to consider the method used to generate HRQL values for calculating quality-adjusted life-years in cost-utility analyses, since choice of method may have a substantial impact on the outcome of the analysis
    • …
    corecore