68 research outputs found
Dilepton Spectra from Decays of Light Unflavored Mesons
The invariant mass spectrum of the and pairs
from decays of light unflavored mesons with masses below the -meson mass to final states containing along with a dilepton pair one
photon, one meson, and two mesons are calculated within the framework of the
effective meson theory. The results can be used for simulations of the dilepton
spectra in heavy-ion collisions and for experimental searches of dilepton meson
decays.Comment: 73 pages, 19 figures, 3 tables, REVTeX, new references adde
Role of baryonic resonances in the dilepton emission in nucleon-nucleon collisions
Within an effective Lagrangian model, we present calculations for cross
sections of the dilepton production in proton-proton and proton-neutron
collisions at laboratory kinetic energies in 1-5 GeV range. Production
amplitudes include contributions from the nucleon-nucleon bremsstrahlung as
well as from the mechanism of excitation, propagation, and radiative decay of
Delta(1232) and N*(1520) intermediate baryonic resonances. It is found that the
delta isobar terms dominate the cross sections in the entire considered beam
energy range. Our calculations are able to explain the data of the DLS
collaboration on the dilepton production in proton-proton collisions for beam
energies below 1.3 GeV. However, for incident energies higher than this the
inclusion of contributions from other dilepton sources like Dalitz decay of pi0
and eta mesons, and direct decay of rho and omega mesons is necessary to
describe the data.Comment: 22 pages, 7 figures, more details of the calculations added, version
to appear in Phys. Rev
Dilepton production in heavy ion collisions at intermediate energies
We present a unified description of the vector meson and dilepton production
in elementary and in heavy ion reactions. The production of vector mesons
() is described via the excitation of nuclear resonances ().
The theoretical framework is an extended vector meson dominance model (eVMD).
The treatment of the resonance decays with arbitrary spin is
covariant and kinematically complete. The eVMD includes thereby excited vector
meson states in the transition form factors. This ensures correct asymptotics
and provides a unified description of photonic and mesonic decays. The
resonance model is successfully applied to the production in
reactions. The same model is applied to the dilepton production in elementary
reactions (). Corresponding data are well reproduced. However, when
the model is applied to heavy ion reactions in the BEVALAC/SIS energy range the
experimental dilepton spectra measured by the DLS Collaboration are
significantly underestimated at small invariant masses. As a possible solution
of this problem the destruction of quantum interference in a dense medium is
discussed. A decoherent emission through vector mesons decays enhances the
corresponding dilepton yield in heavy ion reactions. In the vicinity of the
-peak the reproduction of the data requires further a substantial
collisional broadening of the and in particular of the meson.Comment: 32 pages revtex, 19 figures, to appear in PR
Results from the CUORE-0 experiment
The CUORE-0 experiment searched for neutrinoless double beta decay in 130Te using an array of 52 tellurium dioxide crystals, operated as bolometers at a temperature of 10 mK. It took data in the Gran Sasso National Laboratory (Italy) since March 2013 to March 2015. We present the results of a search for neutrinoless double beta decay in 9.8 kg-years 130Te exposure that allowed us to set the most stringent limit to date on this half-life. The performance of the detector in terms of background and energy resolution is also reported
Low energy analysis techniques for CUORE
CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils inCUORE-0
CUORE and CUORE-0 experiments
Neutrino oscillation experiments proved that neutrinos have mass and this enhanced the interest in neutrinoless double-beta decay (0vßß). The observation of this very rare hypothetical decay would prove the leptonic number violation and would give us indications about neutrinos mass hierarchy and absolute mass scale. CUORE (Cryogenic Underground Observatory for Rare Events) is an array of 988 crystals of TeO2, for a total sensitive mass of 741 kg. Its goal is the observation of 0vßß of 130Te. The crystals, placed into the a dilution cryostat, are operated as bolometers at a temperature close to 10 mK. CUORE commissioning phase has been concluded recently in Gran Sasso National Laboratory, Italy, and data taking is expected to start in spring 2017. If target background rate is reached (0.01counts/day/keV/kg), the sensibility of CUORE will be, in five years of data taking, T1/21026years (1? CL). In order to test the quality of materials and optimize the construction procedures, the collaboration realized CUORE-0, that took data from spring of 2013 to summer 2015. Here, after a brief description of CUORE, I report its commissioning status and CUORE-0 results
Lowering the CUORE energy threshold
The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale double beta decay experiment based on TeO2 cryogenic bolometers and is currently in the last construction stage at the Gran Sasso National Laboratory (LNGS). Its primary goal is to observe neutrino-less double beta decay of 130Te, however thanks to the ultra-low background and large projected exposure it could also be suitable for other rare event searches, as the detection of solar axions, neutrinos from type II supernovae or direct detection of dark matter. The sensitivity for these searches will depend on the performance achieved at the low energy threshold. For this reason a trigger algorithm based on continuous data filtering has been developed which will allow lowering the threshold down to the few keV region. The new trigger has been tested in CUORE-0, a single-tower CUORE prototype consisting of 52 TeO2 bolometers and recently concluded, and here we present the results in terms of trigger efficiency, data selection and low-energy calibration
Status and prospects for CUORE
CUORE is a cryogenic detector consisting of 988 TeO2 crystals, 750 g each, and will be operated at a temperature of ~10 mK, to search for neutrinoless double beta decay (0¿ßß) of 130Te. The detector, in the final stages of construction at the Laboratori Nazionali del Gran Sasso (Italy), will start its operations in 2016. CUORE-0, its pilot experiment, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach. CUORE-0 also made the most precise measurement of the 2¿ßß decay. The expected sensitivity of CUORE to the 0¿ßß 130Te half-life is 9 •1025y, for 5 years of data taking. Here, we report the most recent results of CUORE-0, their implications for CUORE, and the current status of the CUORE experiment
The CUORE cryostat and its bolometric detector
CUORE is a cryogenic detector that will be operated at LNGS to search for neutrinoless double beta decay (0ββ) of 130Te. The detector installation was completed in summer 2016. Before the installation, several cold runs were done to test the cryogenic system performance. In the last cold run the base temperature of 6.3mK was reached in stable condition. CUORE-0, a CUORE prototype, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach
- …