21 research outputs found

    Validation of computerized wheeze detection in young infants during the first months of life

    Get PDF
    Background Several respiratory diseases are associated with specific respiratory sounds. In contrast to auscultation, computerized lung sound analysis is objective and can be performed continuously over an extended period. Moreover, audio recordings can be stored. Computerized lung sounds have rarely been assessed in neonates during the first year of life. This study was designed to determine and validate optimal cut-off values for computerized wheeze detection, based on the assessment by trained clinicians of stored records of lung sounds, in infants aged <1 year. Methods Lung sounds in 120 sleeping infants, of median (interquartile range) postmenstrual age of 51 (44.5–67.5) weeks, were recorded on 144 test occasions by an automatic wheeze detection device (PulmoTrack¼). The records were retrospectively evaluated by three trained clinicians blinded to the results. Optimal cut-off values for the automatically determined relative durations of inspiratory and expiratory wheezing were determined by receiver operating curve analysis, and sensitivity and specificity were calculated. Results The optimal cut-off values for the automatically detected durations of inspiratory and expiratory wheezing were 2% and 3%, respectively. These cutoffs had a sensitivity and specificity of 85.7% and 80.7%, respectively, for inspiratory wheezing and 84.6% and 82.5%, respectively, for expiratory wheezing. Inter-observer reliability among the experts was moderate, with a Fleiss’ Kappa (95% confidence interval) of 0.59 (0.57-0.62) for inspiratory and 0.54 (0.52 - 0.57) for expiratory wheezing. Conclusion Computerized wheeze detection is feasible during the first year of life. This method is more objective and can be more readily standardized than subjective auscultation, providing quantitative and noninvasive information about the extent of wheezing

    Reliability of Single-Use PEEP-Valves Attached to Self-Inflating Bags during Manual Ventilation of Neonates – An In Vitro Study

    Get PDF
    Introduction International resuscitation guidelines suggest to use positive end-expiratory pressure (PEEP) during manual ventilation of neonates. Aim of our study was to test the reliability of self-inflating bags (SIB) with single-use PEEP valves regarding PEEP delivery and the effect of different peak inflation pressures (PIP) and ventilation rates (VR) on the delivered PEEP. Methods Ten new single-use PEEP valves from 5 manufacturers were tested by ventilating an intubated 1kg neonatal manikin containing a lung model with a SIB that was actuated by an electromechanical plunger device. Standard settings: PIP 20cmH2O, VR 60/min, flow 8L/min. PEEP settings of 5 and 10cmH2O were studied. A second test was conducted with settings of PIP 40cmH2O and VR 40/min. The delivered PEEP was measured by a respiratory function monitor (CO2SMO+). Results Valves from one manufacturer delivered no relevant PEEP and were excluded. The remaining valves showed a continuous decay of the delivered pressure during expiration. The median (25th and 75th percentile) delivered PEEP with standard settings was 3.4(2.7–3.8)cmH2O when set to 5cmH2O and 6.1(4.9–7.1)cmH2O when set to 10cmH2O. Increasing the PIP from 20 to 40 cmH2O led to a median (25th and 75th percentile) decrease in PEEP to 2.3(1.8–2.7)cmH2O and 4.3(3.2–4.8)cmH2O; changing VR from 60 to 40/min led to a PEEP decrease to 2.8(2.1–3.3)cmH2O and 5.0(3.5–6.2)cmH2O for both PEEP settings. Conclusion Single-use PEEP valves do not reliably deliver the set PEEP. PIP and VR have an effect on the delivered PEEP. Operators should be aware of these limitations when manually ventilating neonates

    Early Lung Function Testing in Infants with Aortic Arch Anomalies Identifies Patients at Risk for Airway Obstruction

    Get PDF
    BACKGROUND: Aortic arch anomalies (AAA) are rare cardio-vascular anomalies. Right-sided and double-sided aortic arch anomalies (RAAA, DAAA) are distinguished, both may cause airway obstructions. We studied the degree of airway obstruction in infants with AAA by neonatal lung function testing (LFT). PATIENTS AND METHODS: 17 patients (10 RAAA and 7 DAAA) with prenatal diagnosis of AAA were investigated. The median (range) post conception age at LFT was 40.3 (36.6-44.1) weeks, median body weight 3400 (2320-4665) g. Measurements included tidal breathing flow-volume loops (TBFVL), airway resistance (R(aw)) by bodyplethysmography and the maximal expiratory flow at functional residual capacity (V'(max)FRC) by rapid thoracic-abdominal compression (RTC) technique. V'(max)FRC was also expressed in Z-scores, based on published gender-, age and height-specific reference values. RESULTS: Abnormal lung function tests were seen in both RAAA and DAAA infants. Compared to RAAA infants, infants with DAAA had significantly more expiratory flow limitations in the TBFVL, (86% vs. 30%, p<0.05) and a significantly increased R(aw) (p = 0.015). Despite a significant correlation between R(aw) and the Z-score of V'(max)FRC (r = 0.740, p<0.001), there were no statistically significant differences in V'(max)FRC and it's Z-scores between RAAA and DAAA infants. 4 (24%) infants (2 RAAA, 2 DAAA) were near or below the 10(th) percentile of V'(max)FRC, indicating a high risk for airway obstruction. CONCLUSION: Both, infants with RAAA and DAAA, are at risk for airway obstruction and early LFT helps to identify and to monitor these infants. This may support the decision for therapeutic interventions before clinical symptoms arise

    Development of lung function in very low birth weight infants with or without bronchopulmonary dysplasia: Longitudinal assessment during the first 15 months of corrected age

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Very low birth weight (VLBW) infants (< 1,500 g) with bronchopulmonary dysplasia (BPD) develop lung damage caused by mechanical ventilation and maturational arrest. We compared functional lung development after discharge from hospital between VLBW infants with and without BPD.</p> <p>Methods</p> <p>Comprehensive lung function assessment was performed at about 50, 70, and 100 weeks of postmenstrual age in 55 sedated VLBW infants (29 with former BPD [O<sub>2 </sub>supplementation was given at 36 weeks of gestational age] and 26 VLBW infants without BPD [controls]). Mean gestational age (26 vs. 29 weeks), birth weight (815 g vs. 1,125 g), and the proportion of infants requiring mechanical ventilation for ≄7 d (55% vs. 8%), differed significantly between BPD infants and controls.</p> <p>Results</p> <p>Both body weight and length, determined over time, were persistently lower in former BPD infants compared to controls, but no significant between-group differences were noted in respiratory rate, respiratory or airway resistance, functional residual capacity as determined by body plethysmography (FRC<sub>pleth</sub>), maximal expiratory flow at the FRC (V'max <sub>FRC</sub>), or blood gas (pO<sub>2</sub>, pCO<sub>2</sub>) levels. Tidal volume, minute ventilation, respiratory compliance, and FRC determined by SF6 multiple breath washout (representing the lung volume in actual communication with the airways) were significantly lower in former BPD infants compared to controls. However, these differences became non-significant after normalization to body weight.</p> <p>Conclusions</p> <p>Although somatic growth and the development of some lung functional parameters lag in former BPD infants, the lung function of such infants appears to develop in line with that of non-BPD infants when a body weight correction is applied. Longitudinal lung function testing of preterm infants after discharge from hospital may help to identify former BPD infants at risk of incomplete recovery of respiratory function; such infants are at risk of later respiratory problems.</p

    Effect of intubation and mechanical ventilation on exhaled nitric oxide in preterm infants with and without bronchopulmonary dysplasia measured at a median postmenstrual age of 49 weeks

    Get PDF
    BACKGROUND: Exhaled nitric oxide (eNO) is a marker of established airway inflammation in adults and children, but conflicting results have been reported in preterm infants when postnatal eNO is measured during tidal breathing. This study investigated the extent to which intubation and mechanical ventilation (MV) affect eNO and NO production (V’(NO)) in preterm infants with and without bronchopulmonary dysplasia (BPD). PATIENTS AND METHODS: A total of 176 very low birth weight (VLBW) infants (birth weight <1500 g), including 74 (42%) with and 102 (58%) without BPD, were examined at a median postmenstrual age of 49 weeks. Of the 176 infants, 84 (48%) did not require MV, 47 (27%) required MV for <7 days and 45 (26%) required MV for ≄7 days. Exhaled NO and tidal breathing parameters were measured in sleeping infants during tidal breathing, respiratory mechanics were assessed by occlusion tests, and arterialized capillary blood gas was analyzed. RESULTS: eNO was significantly correlated with tidal breathing parameters, while V’(NO) was correlated with growth parameters, including age and body length (p < 0.001 each). Infants who were intubated and received MV for <7 days had significantly lower eNO (p < 0.01) and V’(NO) (p < 0.01) than non-ventilated infants. In contrast, eNO and V’(NO) did not differ significantly in non-ventilated infants and those receiving MV for ≄7 days. Multivariate analysis showed that independent on the duration of MV eNO (p = 0.003) and V’(NO) (p = 0.018) were significantly increased in BPD infants comparable with the effects of intubation and MV on eNO (p = 0.002) and V’(NO) (p = 0.017). CONCLUSIONS: Preterm infants with BPD show only weak postnatal increases in eNO and V’(NO), but these changes may be obscured by the distinct influences of breathing pattern and invasive respiratory support. This limits the diagnostic value of postnatal eNO measurements in the follow-up of BPD infants

    All data for dryad

    No full text
    The table provides the data recorded during our in vitro study about the reliability of single use peep valves during simulated neonatal ventilation. In contains the PIP, PEEP and Vt that could be generated using 10 different peep-valves from 5 manufacturers (2 valves each) using different parameter settings

    Effect of PEEP on tidal volume.

    No full text
    <p>Increase of the delivered tidal volume(V<sub>t</sub>) with increasing difference between the set and delivered PEEP for a PEEP setting of 5 cmH<sup>2</sup>O (top) and 10 cmH<sub>2</sub>O (bottom) and PIP of 20 cmH<sub>2</sub>O (left) and 40 cmH<sub>2</sub>O (right). Presented is the regression line with 95% prediction interval.</p