35 research outputs found

    The fallacy of indexed effective orifice area charts to predict prosthesis-patient mismatch alter prosthesis implantation

    Get PDF
    Aims Indexed effective orifice area (EOAi) charts are used to determine the likelihood of prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR). The aim of this study is to validate whether these EOAi charts, based on echocardiographic normal reference values, can accurately predict PPM.Methods and results In the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Pivotal Trial, 986 patients with aortic valve stenosis/regurgitation underwent AVR with an Avalus valve. Patients were randomly split (50:50) into training and test sets. The mean measured EOAs for each valve size from the training set were used to create an Avalus EOAi chart. This chart was subsequently used to predict PPM in the test set and measures of diagnostic accuracy (sensitivity, specificity, and negative and positive predictive value) were assessed. PPM was defined by an EOAi <= 0.85 cm(2)/m(2) and severe PPM was defined as EOAi <= 0.65 cm(2)/m(2). The reference values obtained from the training set ranged from 1.27 cm(2) for size 19 mm up to 1.81 cm(2) for size 27 mm. The test set had an incidence of 66% of PPM and 24% of severe PPM. The EOAi chart inaccurately predicted PPM in 30% of patients and severe PPM in 22% of patients. For the prediction of PPM, the sensitivity was 87% and the specificity 37%. For the prediction of severe PPM, the sensitivity was 13% and the specificity 98%.Conclusion use of echocardiographic normal reference values for EOAi charts to predict PPM is unreliable due to the large proportion of misclassifications.Thoracic Surger

    The Science of Sungrazers, Sunskirters, and Other Near-Sun Comets

    Get PDF
    This review addresses our current understanding of comets that venture close to the Sun, and are hence exposed to much more extreme conditions than comets that are typically studied from Earth. The extreme solar heating and plasma environments that these objects encounter change many aspects of their behaviour, thus yielding valuable information on both the comets themselves that complements other data we have on primitive solar system bodies, as well as on the near-solar environment which they traverse. We propose clear definitions for these comets: We use the term near-Sun comets to encompass all objects that pass sunward of the perihelion distance of planet Mercury (0.307 AU). Sunskirters are defined as objects that pass within 33 solar radii of the Sun’s centre, equal to half of Mercury’s perihelion distance, and the commonly-used phrase sungrazers to be objects that reach perihelion within 3.45 solar radii, i.e. the fluid Roche limit. Finally, comets with orbits that intersect the solar photosphere are termed sundivers. We summarize past studies of these objects, as well as the instruments and facilities used to study them, including space-based platforms that have led to a recent revolution in the quantity and quality of relevant observations. Relevant comet populations are described, including the Kreutz, Marsden, Kracht, and Meyer groups, near-Sun asteroids, and a brief discussion of their origins. The importance of light curves and the clues they provide on cometary composition are emphasized, together with what information has been gleaned about nucleus parameters, including the sizes and masses of objects and their families, and their tensile strengths. The physical processes occurring at these objects are considered in some detail, including the disruption of nuclei, sublimation, and ionisation, and we consider the mass, momentum, and energy loss of comets in the corona and those that venture to lower altitudes. The different components of comae and tails are described, including dust, neutral and ionised gases, their chemical reactions, and their contributions to the near-Sun environment. Comet-solar wind interactions are discussed, including the use of comets as probes of solar wind and coronal conditions in their vicinities. We address the relevance of work on comets near the Sun to similar objects orbiting other stars, and conclude with a discussion of future directions for the field and the planned ground- and space-based facilities that will allow us to address those science topics

    Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies

    Get PDF
    Objectives: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. Background: Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ∼10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. Methods: The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. Results: Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. Conclusions: This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data

    Integrated analysis of environmental and genetic influences on cord blood DNA methylation in new-borns

    Get PDF
    Epigenetic processes, including DNA methylation (DNAm), are among the mechanisms allowing integration of genetic and environmental factors to shape cellular function. While many studies have investigated either environmental or genetic contributions to DNAm, few have assessed their integrated effects. Here we examine the relative contributions of prenatal environmental factors and genotype on DNA methylation in neonatal blood at variably methylated regions (VMRs) in 4 independent cohorts (overall n = 2365). We use Akaike’s information criterion to test which factors best explain variability of methylation in the cohort-specific VMRs: several prenatal environmental factors (E), genotypes in cis (G), or their additive (G + E) or interaction (GxE) effects. Genetic and environmental factors in combination best explain DNAm at the majority of VMRs. The CpGs best explained by either G, G + E or GxE are functionally distinct. The enrichment of genetic variants from GxE models in GWAS for complex disorders supports their importance for disease risk

    No greater incidence or worsening of cardiac valve regurgitation with somatostatin analog treatment of acromegaly.

    No full text
    CONTEXT: Excess GH and IGF-I in acromegaly are associated with reduced life expectancy due to cardiovascular complications. OBJECTIVE: The objective of the study was to investigate the prevalence, incidence, and severity of cardiac valve regurgitation before and after somatostatin-analog treatment in acromegaly. DESIGN: This was a prospective, observer-blinded, multicenter, 12-month study. SETTING: The study was conducted at 33 specialist centers. PATIENTS: The study population consisted of 225 adult patients with acromegaly without significant cardiac valve abnormalities or prior valve-replacement surgery, matched for age, sex, and center/country/study. INTERVENTIONS: Interventions included initiation/continuation of lanreotide (n = 107) or octreotide treatment (n = 118), tailored for optimal disease control. MAIN OUTCOME MEASURES: Relative risk of new/worsening regurgitation in any valve at 12 months compared with baseline, was measured. RESULTS: At baseline, almost 80% of patients had some degree of cardiac valve regurgitation, although none was severe. The risk of developing new/worsening regurgitation in any valve at 12 months was nonsignificant and similar for the cohorts [adjusted odds ratio 0.86; 95% confidence interval (CI) 0.41-1.82; P = 0.694; relative risk 1.04; 95% CI 0.67-1.60; risk difference 0.01; 95% CI -0.13 to 0.16]. For 54% of patients, the severity of regurgitation stayed the same during the study. At baseline, significant valve regurgitation occurred in 18% of patients (lanreotide cohort) and 13% (octreotide cohort) and at 12 months in 18% of each cohort. CONCLUSIONS: The incidence of valve regurgitation did not change over 12 months of treatment with somatostatin analogs, and most cases were physiologic or mild in severity. There was no significant difference between somatostatin analogs in the risk of developing new/worsening valve regurgitation or significant regurgitation after 1 yr

    Surgical aortic valve replacement with a stented pericardial bioprosthesis: 5-year outcomes

    No full text
    OBJECTIVES This analysis evaluated the safety, durability and haemodynamic performance of a stented bovine pericardial valve through 5 years of follow-up in patients with an indication for surgical aortic valve replacement.METHODS Kaplan-Meier analysis was used to estimate the incidence of survival and valve-related thromboembolism, major paravalvular leak, endocarditis, structural valve deterioration (SVD) and reintervention. The mean aortic gradient and New York Heart Association (NYHA) functional class were also evaluated.RESULTS A total of 1118 patients have received the Avalus valve; 564 have completed the 5-year follow-up. The median follow-up was 4.85 years (4810 patient-years total follow-up). At baseline, the mean age was 70.2 +/- 9.0 years; 75.1% of patients were male. The Society of Thoracic Surgeons predicted risk of mortality was 2.0 +/- 1.4%. Most patients were in NYHA functional class II (46.8%) or III (40.3%). At the 5-year follow-up, the overall Kaplan-Meier survival rate was 88.1% (85.9-90.0%). The Kaplan-Meier event rates were 5.6% (4.3-7.2%) for thromboembolism, 4.4% (3.2-6.0%) for endocarditis, 0.2% (0.0-0.7%) for a major paravalvular leak and 3.2% (2.3-4.6%) for reintervention. There were no cases of SVD. The mean gradient decreased from 42.1 +/- 17.1 mmHg at baseline, to 13.1 +/- 4.7 mmHg at discharge and remained stable at 12.5 +/- 4.6 mmHg at 5 years. More than 95% of patients were in NYHA functional class I/II 5 years after surgery.CONCLUSIONS The findings of a high survival rate, excellent safety, no SVD and stable haemodynamic performance and functional status through 5 years of follow-up are encouraging. Additional follow-up is needed to assess the long-term durability of this contemporary surgical bioprosthesis.Thoracic Surger
    corecore