314 research outputs found

    Space-time coupling of shaped ultrafast ultraviolet pulses from an acousto-optic programmable dispersive filter

    Full text link
    A comprehensive experimental analysis of spatio-temporal coupling effects inherent to the acousto-optic programmable dispersive filter (AOPDF) is presented. Phase and amplitude measurements of the AOPDF transfer function are performed using spatially and spectrally resolved interferometry. Spatio-temporal and spatio-spectral coupling effects are presented for a range of shaped pulses that are commonly used in quantum control experiments. These effects are shown to be attributable to a single mechanism: a group-delay--dependent displacement of the shaped pulse. The physical mechanism is explained and excellent quantitative agreement between the measured and calculated coupling speed is obtained. The implications for quantum control experiments are discussed.Comment: 8 pages, 6 figures; accepted for publication within JOSA

    Control of Raman Lasing in the Nonimpulsive Regime

    Full text link
    We explore coherent control of stimulated Raman scattering in the nonimpulsive regime. Optical pulse shaping of the coherent pump field leads to control over the stimulated Raman output. A model of the control mechanism is investigated.Comment: 4 pages, 5 figure

    Immune Curbing of Cancer Stem Cells by CTLs Directed to NANOG

    Get PDF
    Cancer stem cells (CSCs) have been identified as the source of tumor growth and disease recurrence. Eradication of CSCs is thus essential to achieve durable responses, but CSCs are resistant to current anti-tumor therapies. Novel therapeutic approaches that specifically target CSCs will, therefore, be crucial to improve patient outcome. Immunotherapies, which boost the body’s own immune system to eliminate cancerous cells, could be an alternative approach to target CSCs. Vaccines of dendritic cells (DCs) loaded with tumor antigens can evoke highly specific anti-tumor T cell responses. Importantly, DC vaccination also promotes immunological memory formation, paving the way for long-term cancer control. Here, we propose a DC vaccination that specifically targets CSCs. DCs loaded with NANOG peptides, a protein required for maintaining stem cell properties, could evoke a potent anti-tumor immune response against CSCs. We hypothesize that the resulting immunological memory will also control newly formed CSCs, thereby preventing disease recurrence

    FAST CARS: Engineering a Laser Spectroscopic Technique for Rapid Identification of Bacterial Spores

    Get PDF
    Airborne contaminants, e.g., bacterial spores, are usually analyzed by time consuming microscopic, chemical and biological assays. Current research into real time laser spectroscopic detectors of such contaminants is based on e.g. resonant Raman spectroscopy. The present approach derives from recent experiments in which atoms and molecules are prepared by one (or more) coherent laser(s) and probed by another set of lasers. The connection with previous studies based on "Coherent Anti-Stokes Raman Spectroscopy" (CARS) is to be noted. However generating and utilizing maximally coherent oscillation in macromolecules having an enormous number of degrees of freedom is much more challenging. This extension of the CARS technique is called FAST CARS (Femtosecond Adaptive Spectroscopic Techniques for Coherent Anti-Stokes Raman Spectroscopy), and the present paper proposes and analyses ways in which it could be used to rapidly identify pre-selected molecules in real time.Comment: 43 pages, 21 figures; replacement with references added. Submitted to the Proceedings of National Academy of Science

    Beta-delayed proton emission in the 100Sn region

    Full text link
    Beta-delayed proton emission from nuclides in the neighborhood of 100Sn was studied at the National Superconducting Cyclotron Laboratory. The nuclei were produced by fragmentation of a 120 MeV/nucleon 112Sn primary beam on a Be target. Beam purification was provided by the A1900 Fragment Separator and the Radio Frequency Fragment Separator. The fragments of interest were identified and their decay was studied with the NSCL Beta Counting System (BCS) in conjunction with the Segmented Germanium Array (SeGA). The nuclei 96Cd, 98Ing, 98Inm and 99In were identified as beta-delayed proton emitters, with branching ratios bp = 5.5(40)%, 5.5+3 -2%, 19(2)% and 0.9(4)%, respectively. The bp for 89Ru, 91,92Rh, 93Pd and 95Ag were deduced for the first time with bp = 3+1.9 -1.7%, 1.3(5)%, 1.9(1)%, 7.5(5)% and 2.5(3)%, respectively. The bp = 22(1)% for 101Sn was deduced with higher precision than previously reported. The impact of the newly measured bp values on the composition of the type-I X-ray burst ashes was studied.Comment: 15 pages, 14 Figures, 4 Table

    A monitor for Cellular Oxygen METabolism (COMET): monitoring tissue oxygenation at the mitochondrial level

    Get PDF
    After introduction of the protoporphyrin IX-triplet state lifetime technique as a new method to measure mitochondrial oxygen tension in vivo, the development of a clinical monitor was started. This monitor is the “COMET”, an acronym for Cellular Oxygen METabolism. The COMET is a non-invasive electrically powered optical device that allows measurements on the skin. The COMET is easy to transport, due to its lightweight and compact size. After 5-aminolevulinic acid application on the human skin, a biocompatible sensor enables detection of PpIX in the mitochondria. PpIX acts as a mitochondrially located oxygen-sensitive dye. Three measurement types are available in the touchscreen-integrated user interface, ‘Single’, ‘Interval’ and ‘Dynamic measurement’. COMET is currently used in several clinical studies in our institution. In this first description of the COMET device we show an incidental finding during neurosurgery. To treat persisting intraoperative hypertension a patient was administered clonidine, but due to rapid administration an initial phase of peripheral vasoconstriction occurred. Microvascular flow and velocity parameters measured with laser-doppler (O2C, LEA Medizintechnik) decreased by 44 and 16% respectively, but not the venous-capillary oxygen saturation. However, mitochondrial oxygen tension in the skin detected by COMET decreased from a steady state of 48 to 16 mmHg along with the decrease in flow and velocity. We conclude that COMET is ready for clinical application and we see the future for this bedside monitor on the intensive care, operating theater, and testing of mitochondrial effect of pharmaceuticals

    Spontaneous Regression of Ovarian Carcinoma After Septic Peritonitis; A Unique Case Report

    Get PDF
    Despite advances in therapy, ovarian cancer remains the most lethal gynecological malignancy and prognosis has not substantially improved over the past 3 decades. Immunotherapy is a promising new treatment option. However, the immunosuppressive cancer microenvironment must be overcome for immunotherapy to be successful. Here, we present a unique case of spontaneous regression of ovarian carcinoma after septic peritonitis. A 79-year-old woman was diagnosed with stage IIIc ovarian cancer. The omental cake biopsy was complicated by sepsis. Although the patient recovered, her physical condition did not allow further treatment for her ovarian cancer. After 6 months, spontaneous regression of the tumor was observed during surgery. Analysis of the immune infiltrate in the tissues showed a shift from a pro-tumorigenic to an anti-tumorigenic immune response after sepsis. Strong activation of the immune system during sepsis overruled the immunosuppressive tumor microenvironment and allowed for a potent anti-tumor immune response. More understanding of immunological responses in cases with cancer and septic peritonitis might be crucial to identify potential new targets for immunotherapy

    Survival of Ovarian Cancer Patients Is Independent of the Presence of DC and T Cell Subsets in Ascites

    Get PDF
    Ascites is a prominent feature of ovarian cancer and could serve as liquid biopsy to assess the immune status of patients. Tumor-infiltrating T lymphocytes are correlated with improved survival in ovarian cancer. To investigate whether immune cells in ascites are associated with patient outcome, we analyzed the amount of dendritic cell (DC) and T cell subsets in ascites from ovarian cancer patients diagnosed with high-grade serous cancer (HGSC). Ascites was collected from 62 HGSC patients prior to chemotherapy. Clinicopathological, histological and follow-up data from patients were collected. Ascites-derived immune cells were isolated using density-gradient centrifugation. The presence of myeloid DCs (BDCA-1+, BDCA-3+, CD16+), pDCs (CD123+BDCA-2+), and T cells (CD4+, CD8+) was analyzed using flow cytometry. Complete cytoreduction, response to primary treatment and chemosensitivity were associated with improved patient outcome. In contrast, immune cells in ascites did not significantly correlate with patient survival. However, we observed a trend toward improved outcome for patients having low percentages of CD4+ T cells. Furthermore, we assessed the expression of co-stimulatory and co-inhibitory molecules on T cells and non-immune cells in 10 ascites samples. PD-1 was expressed by 30% of ascites-derived T cells and PD-L1 by 50% of non-immune cells. However, the percentage of DC and T cell subsets in ascites was not directly correlated to the survival of HGSC patients

    Effect of mill type on the size reduction and phase transformation of gamma alumina

    Get PDF
    The influence of stress modes and comminution conditions on the effectiveness of particle size reduction of a common catalyst support; γ-Alumina is examined through a comparative assessment of three different mill types. Air jet milling is found to be the most effective in reducing particle size from a d90 of 37 ”m to 2.9 ”m compared to planetary ball milling (30.2 ”m) and single ball milling (10.5 ”m). XRD and TEM studies confirm that the planetary ball mill causes phase transformation to the less desired α-Alumina resulting in a notable decrease in surface area from 136.6 m2/g to 82.5 m2/g as measured by the BET method. This is consistent with the large shear stresses under high shear rates prevailing in the planetary ball mill when compared to the other mill types. These observations are consistent with a shear-induced phase transformation mechanism brought about by slip on alternate close packed oxygen layers from a cubic close packed to a hexagonal close packed structure

    Non-invasive versus ex vivo measurement of mitochondrial function in an endotoxemia model in rat: Toward monitoring of mitochondrial therapy

    Get PDF
    Mitochondrial function has been predominantly measured ex vivo. Due to isolation and preservation procedures ex vivo measurements might misrepresent in vivo mitochondrial conditions. Direct measurement of in vivo mitochondrial oxygen tension (mitoPO2) and oxygen disappearance rate (ODR) with the protoporphyrin IX‐triplet state lifetime technique (PpIX-TSLT) might increase our understanding of mitochondrial dysfunction in the pathophysiology of acute disease. LPS administration decreased mitochondrial respiration (ODR) in vivo but did not alter mitochondrial function as assessed with ex vivo techniques (high resolution respirometry and specific complex determinations). PpIX-TSLT measures in vivo mitoPO2 and ODR and can be applied non-invasively at the skin
    • 

    corecore