5,075 research outputs found

    Observations of Subarcsecond Bright Dots in the Transition Region above Sunspots with the Interface Region Imaging Spectrograph

    Full text link
    Observations with the Interface Region Imaging Spectrograph (IRIS) have revealed numerous sub-arcsecond bright dots in the transition region above sunspots. These bright dots are seen in the 1400\AA{} and 1330\AA{} slit-jaw images. They are clearly present in all sunspots we investigated, mostly in the penumbrae, but also occasionally in some umbrae and light bridges. The bright dots in the penumbrae typically appear slightly elongated, with the two dimensions being 300--600 km and 250--450 km, respectively. The long sides of these dots are often nearly parallel to the bright filamentary structures in the penumbrae but sometimes clearly deviate from the radial direction. Their lifetimes are mostly less than one minute, although some dots last for a few minutes or even longer. Their intensities are often a few times stronger than the intensities of the surrounding environment in the slit-jaw images. About half of the bright dots show apparent movement with speeds of \sim10--40~km~s1^{-1} in the radial direction. Spectra of a few bright dots were obtained and the Si~{\sc{iv}}~1402.77\AA{} line profiles in these dots are significantly broadened. The line intensity can be enhanced by one to two orders of magnitude. Some relatively bright and long-lasting dots are also observed in several passbands of the Atmospheric Imaging Assembly onboard the Solar Dynamics Observatory, and they appear to be located at the bases of loop-like structures. Many of these bright dots are likely associated with small-scale energy release events at the transition region footpoints of magnetic loops.Comment: 5 figures, will appear in ApJ

    Highly indistinguishable single photons from incoherently and coherently excited GaAs quantum dots

    Full text link
    Semiconductor quantum dots are converging towards the demanding requirements of photonic quantum technologies. Among different systems, quantum dots with dimensions exceeding the free-exciton Bohr radius are appealing because of their high oscillator strengths. While this property has received much attention in the context of cavity quantum electrodynamics, little is known about the degree of indistinguishability of single photons consecutively emitted by such dots and on the proper excitation schemes to achieve high indistinguishability. A prominent example is represented by GaAs quantum dots obtained by local droplet etching, which recently outperformed other systems as triggered sources of entangled photon pairs. On these dots, we compare different single-photon excitation mechanisms, and we find (i) a "phonon bottleneck" and poor indistinguishability for conventional excitation via excited states and (ii) photon indistinguishablilities above 90% for both strictly resonant and for incoherent acoustic- and optical-phonon-assisted excitation. Among the excitation schemes, optical phonon-assisted excitation enables straightforward laser rejection without a compromise on the source brightness together with a high photon indistinguishability

    Evaluation of the diagnostic accuracy of a point-of-care device to measure concentrations of nonesterified fatty acids in serum and whole blood

    Get PDF
    The objective of this study was to compare measurements of nonesterified fatty acids (NEFA) between the gold standard diagnostic laboratory method and a handheld NEFA meter (Qucare Pro meter, DFI Co. Ltd.). Three experiments were conducted to study the usability of the meter. In experiment 1 we compared results of the meter obtained from measurements in serum and whole blood with results of the gold standard method. Based on the results of experiment 1 we compared the results measured by the meter in whole blood with results obtained from the gold standard method on a larger scale, as we wanted to omit the step of centrifugation with the cow-side test. In experiment 3 we determined the influence of ambient temperature on measurements. Overall, blood samples of 231 cows were collected between 14 and 20 d in milk. The Spearman correlation coefficients (ρ) were calculated and Bland-Altman plots were created to compare the accuracy of the NEFA meter with the gold standard. In addition, in experiment 2 receiver operating characteristic (ROC) curve analyses were performed, to define thresholds for the NEFA meter to detect cows with a NEFA concentration above 0.3, 0.4, and 0.7 mEq/L. In experiment 1, there was a high correlation between NEFA concentrations in whole blood and serum determined by the NEFA meter and the gold standard (ρ = 0.90 for measurement in whole blood; ρ = 0.93 for measurement in serum). In experiment 2, the measurement in whole blood with the NEFA meter was compared with the gold standard. Despite a lower correlation (ρ = 0.79) the ROC curve analyses revealed a high specificity and a moderate sensitivity for lower cut-points (i.e., 0.3 and 0.4 mEq/L). The NEFA meter underestimated especially high concentration of >0.7 mEq/L. Considering thresholds of 0.3, 0.4, and 0.7 mEq/L measured by the gold standard test, sensitivity and specificity were 59.1% and 96.7%, 79.0% and 95.4%, and 86.4% and 95.6%, respectively, when using 0.3, 0.3, and 0.4 mEq/L as thresholds for the NEFA meter. Accuracy was 74.1%, 88.3%, and 93.8% for the 3 thresholds tested. Experiment 3 showed that measurements should be conducted at approximately 21°C (ρ = 0.73) as correlations were poor at 6.2°C and 15.1°C (ρ = 0.18 and 0.22, respectively)

    Operation of a high purity germanium crystal in liquid argon as a Compton suppressed radiation spectrometer

    Get PDF
    A high purity germanium crystal was operated in liquid argon as a Compton suppressed radiation spectrometer. Spectroscopic quality resolution of less than 1% of the full-width half maximum of full energy deposition peaks was demonstrated. The construction of the small apparatus used to obtain these results is reported. The design concept is to use the liquid argon bath to both cool the germanium crystal to operating temperatures and act as a scintillating veto. The scintillation light from the liquid argon can veto cosmic-rays, external primordial radiation, and gamma radiation that does not fully deposit within the germanium crystal. This technique was investigated for its potential impact on ultra-low background gamma-ray spectroscopy. This work is based on a concept initially developed for future germanium-based neutrinoless double-beta decay experiments.Comment: Paper presented at the SORMA XI Conference, Ann Arbor, MI, May 200

    Mutations affecting cleavage at the p10-capsid protease cleavage site block Rous sarcoma virus replication

    Get PDF
    A series of amino acid substitutions (M239F, M239G, P240F, V241G) were placed in the p10-CA protease cleavage site (VVAM*PVVI) to change the rate of cleavage of the junction. The effects of these substitutions on p10-CA cleavage by RSV PR were confirmed by measuring the kinetics of cleavage of model peptide substrates containing the wild type and mutant p10-CA sites. The effects of these substitutions on processing of the Gag polyprotein were determined by labeling Gag transfected COS-1 cells with (35)S-Met and -Cys, and immunoprecipitation of Gag and its cleavage products from the media and lysate fractions. All substitutions except M239F caused decreases in detectable Gag processing and subsequent release from cells. Several of the mutants also caused defects in production of the three CA proteins. The p10-CA mutations were subcloned into an RSV proviral vector (RCAN) and introduced into a chick embryo fibroblast cell line (DF-1). All of the mutations except M239F blocked RSV replication. In addition, the effects of the M239F and M239G substitutions on the morphology of released virus particles were examined by electron microscopy. While the M239F particles appeared similar to wild type particles, M239G particles contained cores that were large and misshapen. These results suggest that mutations affecting cleavage at the p10-CA protease cleavage site block RSV replication and can have a negative impact on virus particle morphology

    Randomized clinical trial to evaluate the effects of a prepartum cholecalciferol injection on postpartum serum calcium dynamics and health and performance in early-lactation multiparous dairy cows

    Get PDF
    The objectives of the present study were (1) to evaluate the effect of prepartum cholecalciferol treatment on serum Ca concentration during the first 10 d after calving and (2) to evaluate the effect of treatment on subsequent health and performance. Multiparous Holstein cows (n = 377) from one dairy farm were fed a negative dietary cation-anion difference diet (−31 mEq/kg of DM) for the last 21 d of gestation. On d 275, the animals were randomly assigned to a control or a treatment group. Cows in the control group were left untreated, and cows in the treatment group received an injection of 12 × 106 IU of cholecalciferol intramuscularly on the day of enrollment. If treated cows did not deliver the calf within 6 d, they were reinjected with 10 × 106 IU of cholecalciferol. Blood samples were drawn on 1, 2, 3, 5, 7, and 10 days in milk (DIM) and analyzed for serum Ca, P, and Mg concentrations. In a subsample of cows (50 control cows, 35 cows treated once with cholecalciferol, and 15 cows treated twice) serum haptoglobin, nonesterified fatty acids, β-hydroxybutyrate, and 25-hydroxycholecalciferol concentrations were analyzed on 1, 5, and 10 DIM. Binary data [retained placenta (RP), metritis] were analyzed using logistic regression models. Repeated measures ANOVA with first-order autoregressive covariance was performed to evaluate the treatment effect on milk yield over the first 10 test days after parturition, 25-hydroxycholecalciferol, serum Ca, P, Mg, β-hydroxybutyrate, nonesterified fatty acids, and haptoglobin concentrations. Cox proportional hazards were used to model the time to event outcomes (time to pregnancy within 200 d, culling until 300 DIM). After enrollment of 31.4% of cows and a preliminary analysis, adverse reactions became apparent, and the study was stopped. Cows treated with cholecalciferol had a greater risk of incurring RP and metritis. The adjusted mean incidences were 2.0%, 7.7%, and 4.0% for RP, and 21.6%, 39.3%, and 33.3% for metritis for control cows, cows treated once, and cows treated twice with cholecalciferol, respectively. Compared with control cows, cows injected once with 12 × 106 IU of cholecalciferol produced less energy-corrected milk on the first (−3.76 kg) and second (−2.75 kg) test days, respectively. Cows injected twice with cholecalciferol (12 × 106 IU of cholecalciferol and 10 × 106 IU 1 wk later) had a reduced milk yield only at first test day (−3.80 kg). Treatment with cholecalciferol led to a significant increase in 25-hydroxycholecalciferol on d 1, 5, and 10 after calving. Serum Ca and P concentrations were significantly increased in cows treated with cholecalciferol, but serum Mg concentrations were significantly reduced. Haptoglobin concentrations were significantly increased on 5 DIM in cows injected once with 12 × 106 IU of cholecalciferol. Although we observed no effect of treatment on culling until 300 DIM, time to pregnancy was delayed by 34 d in cows injected once with 12 × 106 IU of cholecalciferol. In the present study, injection with 12 × 106 IU of cholecalciferol had detrimental effects on health and milk production despite the beneficial effects on Ca homeostasis
    corecore