988 research outputs found

    THE BACKGROUND OF SNOPESISM IN MISSISSIPPI POLITICS

    Get PDF
    THE BACKGROUND OF SNOPESISM IN MISSISSIPPI POLITIC

    Tunable fibre-coupled multiphoton microscopy with a negative curvature fibre

    Get PDF
    Negative curvature fibre (NCF) guides light in its core by inhibiting the coupling of core and cladding modes. In this work, an NCF was designed and fabricated to transmit ultrashort optical pulses for multiphoton microscopy with low group velocity dispersion (GVD) at 800 nm. Its attenuation was measured to be <0.3 dB m(-1) over the range 600-850 nm and the GVD was -180 ± 70 fs(2)  m(-1) at 800 nm. Using an average fibre output power of ∼20 mW and pulse repetition rate of 80 MHz, the NCF enabled pulses with a duration of <200 fs to be transmitted through a length of 1.5 m of fibre over a tuning range of 180 nm without the need for dispersion compensation. In a 4 m fibre, temporal and spectral pulse widths were maintained to within 10% of low power values up to the maximum fibre output power achievable with the laser system used of 278 mW at 700 nm, 808 mW at 800 nm and 420 mW at 860 nm. When coupled to a multiphoton microscope, it enabled imaging of ex vivo tissue using excitation wavelengths from 740 nm to 860 nm without any need for adjustments to the set-up

    Homo-FRET Based Biosensors and Their Application to Multiplexed Imaging of Signalling Events in Live Cells.

    Get PDF
    Multiplexed imaging of Förster Resonance Energy Transfer (FRET)-based biosensors potentially presents a powerful approach to monitoring the spatio-temporal correlation of signalling pathways within a single live cell. Here, we discuss the potential of homo-FRET based biosensors to facilitate multiplexed imaging. We demonstrate that the homo-FRET between pleckstrin homology domains of Akt (Akt-PH) labelled with mCherry may be used to monitor 3′-phosphoinositide accumulation in live cells and show how global analysis of time resolved fluorescence anisotropy measurements can be used to quantify this accumulation. We further present multiplexed imaging readouts of calcium concentration, using fluorescence lifetime measurements of TN-L15-a CFP/YFP based hetero-FRET calcium biosensor-with 3′-phosphoinositide accumulation

    Correction Approach for Delta Function Convolution Model Fitting of Fluorescence Decay Data in the Case of a Monoexponential Reference Fluorophore

    Get PDF
    A correction is proposed to the Delta function convolution method (DFCM) for fitting a multiexponential decay model to time-resolved fluorescence decay data using a monoexponential reference fluorophore. A theoretical analysis of the discretised DFCM multiexponential decay function shows the presence an extra exponential decay term with the same lifetime as the reference fluorophore that we denote as the residual reference component. This extra decay component arises as a result of the discretised convolution of one of the two terms in the modified model function required by the DFCM. The effect of the residual reference component becomes more pronounced when the fluorescence lifetime of the reference is longer than all of the individual components of the specimen under inspection and when the temporal sampling interval is not negligible compared to the quantity (τ(R)(−1) – τ(−1))(−1), where τ(R) and τ are the fluorescence lifetimes of the reference and the specimen respectively. It is shown that the unwanted residual reference component results in systematic errors when fitting simulated data and that these errors are not present when the proposed correction is applied. The correction is also verified using real data obtained from experiment

    Neuraminidase Activity in \u3cem\u3eDiplococcus pneumoniae\u3c/em\u3e

    Get PDF
    Kelly, R. T. (Marquette University School of Medicine, Milwaukee, Wis.), D. Greiff, and S. Farmer. Neuraminidase activity in Diplococcus pneumoniae. J. Bacteriol. 91:601–603. 1966.—A method for the quantitation of neuraminidase in the presence of N-acetylneuraminic acid aldolase is described. The neuraminidase content of Diplococcus pneumoniae was found to be dependent on the media employed for growth; the highest enzyme activity per milligram of bacterial protein was obtained with Todd-Hewitt broth. Neuraminidase production was stimulated in D. pneumoniae by the addition of N-acetylneuraminlactose, N-acetylneuraminic acid, or N-acetylmannosamine to the growth medium. Three rough strains of D. pneumoniae, which were nonpathogenic for mice, lacked neuraminidase activity. Seven of 12 smooth strains contained neuraminidase; enzyme activity was not detected in the remaining 5 smooth strains. There was no correlation between the presence of neuraminidase activity and the capsular type or between neuraminidase production and animal virulence

    Intertranslatability, Theoretical Equivalence, and Perversion

    Get PDF
    I investigate syntactic notions of theoretical equivalence between logical theories and an recent objection thereto. I show that this recent criticism of syntactic accounts as extensionally inadequate is unwarranted by developing an account which is plausibly extensionally adequate and more philosophically motivated. This is important for recent anti-exceptionalist treatments of logic since syntactic accounts require less theoretical baggage than semantic accounts

    Visualising apoptosis in live zebrafish using fluorescence lifetime imaging with optical projection tomography to map FRET biosensor activity in space and time

    Get PDF
    Fluorescence lifetime imaging (FLIM) combined with optical projection tomography (OPT) has the potential to map Förster resonant energy transfer (FRET) readouts in space and time in intact transparent or near transparent live organisms such as zebrafish larvae, thereby providing a means to visualise cell signalling processes in their physiological context. Here the first application of FLIM OPT to read out biological function in live transgenic zebrafish larvae using a genetically expressed FRET biosensor is reported. Apoptosis, or programmed cell death, is mapped in 3-D by imaging the activity of a FRET biosensor that is cleaved by Caspase 3, which is a key effector of apoptosis. Although apoptosis is a naturally occurring process during development, it can also be triggered in a variety of ways, including through gamma irradiation. FLIM OPT is shown here to enable apoptosis to be monitored over time, in live zebrafish larvae via changes in Caspase 3 activation following gamma irradiation at 24 hours post fertilisation. Significant apoptosis was observed at 3.5 hours post irradiation, predominantly in the head region

    Fibre-coupled multiphoton microscope with adaptive motion compensation

    Get PDF
    To address the challenge of sample motion during in vivo imaging, we present a fibre-coupled multiphoton microscope with active axial motion compensation. The position of the sample surface is measured using optical coherence tomography and fed back to a piezo actuator that adjusts the axial location of the objective to compensate for sample motion. We characterise the system’s performance and demonstrate that it can compensate for axial sample velocities up to 700 µm/s. Finally we illustrate the impact of motion compensation when imaging multiphoton excited autofluorescence in ex vivo mouse skin

    Adaptive multiphoton endomicroscopy through a dynamically deformed multicore optical fiber using proximal detection

    No full text
    This paper demonstrates multiphoton excited fluorescence imaging through a polarisation maintaining multicore fiber (PM-MCF) while the fiber is dynamically deformed using all-proximal detection. Single-shot proximal measurement of the relative optical path lengths of all the cores of the PM-MCF in double pass is achieved using a Mach-Zehnder interferometer read out by a scientific CMOS camera operating at 416 Hz. A non-linear least squares fitting procedure is then employed to determine the deformation-induced lateral shift of the excitation spot at the distal tip of the PM-MCF. An experimental validation of this approach is presented that compares the proximally measured deformation-induced lateral shift in focal spot position to an independent distally measured ground truth. The proximal measurement of deformation-induced shift in focal spot position is applied to correct for deformation-induced shifts in focal spot position during raster-scanning multiphoton excited fluorescence imaging
    • …
    corecore