132 research outputs found

    The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures

    Full text link
    The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE

    Search for Neutrinoless Double-Beta Decay of 130^{130}Te with CUORE-0

    Get PDF
    We report the results of a search for neutrinoless double-beta decay in a 9.8~kg⋅\cdotyr exposure of 130^{130}Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are 5.1±0.3 keV5.1\pm 0.3{\rm~keV} FWHM and 0.058±0.004 (stat.)±0.002 (syst.)0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})~counts/(keV⋅\cdotkg⋅\cdotyr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is 2.9×1024 yr2.9\times 10^{24}~{\rm yr} and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of 130^{130}Te and place a Bayesian lower bound on the decay half-life, T1/20ν>T^{0\nu}_{1/2}>~2.7×1024 yr 2.7\times 10^{24}~{\rm yr} at 90%~C.L. Combining CUORE-0 data with the 19.75~kg⋅\cdotyr exposure of 130^{130}Te from the Cuoricino experiment we obtain T1/20ν>4.0×1024 yrT^{0\nu}_{1/2} > 4.0\times 10^{24}~\mathrm{yr} at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, mββ<270m_{\beta\beta}< 270 -- 760 meV760~\mathrm{meV}.Comment: 6 pages, 5 figures, updated version as published in PR

    Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in 130^{130}Te with CUORE-0

    Full text link
    We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta (0νββ0\nu\beta\beta) decay in 130^{130}Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive 0νββ0\nu\beta\beta decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final 0νββ0\nu\beta\beta decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized 0νββ0\nu\beta\beta decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the 0νββ0\nu\beta\beta decay half-life limits previously reported for CUORE-0, T1/20ν>2.7×1024T^{0\nu}_{1/2}>2.7\times10^{24} yr, and in combination with the Cuoricino limit, T1/20ν>4.0×1024T^{0\nu}_{1/2}>4.0\times10^{24} yr.Comment: 18 pages, 18 figures. (Version 3 reflects only minor changes to the text. Few additional details, no major content changes.

    Measurement of the Two-Neutrino Double Beta Decay Half-life of 130^{130}Te with the CUORE-0 Experiment

    Get PDF
    We report on the measurement of the two-neutrino double beta decay half-life of 130^{130}Te with the CUORE-0 detector. From an exposure of 33.4 kg⋅\cdoty of TeO2_2, the half-life is determined to be T1/22νT_{1/2}^{2\nu} = [8.2 ±\pm 0.2 (stat.) ±\pm 0.6 (syst.)] ×\times 1020^{20}y. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the 130^{130}Te neutrinoless double beta decay region of interest.Comment: Corrected typo in section 9: 3.43E5 Bq/kg should have read 3.43E-5 Bq/k

    Measurement of the 2νββ Decay Half-Life of Te 130 with CUORE

    Get PDF
    We measured two-neutrino double beta decay of Te130 using an exposure of 300.7 kg yr accumulated with the CUORE detector. Using a Bayesian analysis to fit simulated spectra to experimental data, it was possible to disentangle all the major background sources and precisely measure the two-neutrino contribution. The half-life is in agreement with past measurements with a strongly reduced uncertainty: T1/22ν=7.71-0.06+0.08(stat)-0.15+0.12(syst)×1020 yr. This measurement is the most precise determination of the Te130 2νββ decay half-life to date

    Search for Neutrinoless Double-Beta Decay of Te-130 with CUORE-0

    Get PDF
    We report the results of a search for neutrinoless double-beta decay in a 9.8 kg·yr exposure of 130Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are 5.1 ± 0.3 keV FWHM and 0.058 ± 0.004 (stat.) ± 0.002 (syst.) counts/(keV·kg·yr), respectively. The median 90 % C.L. lower-limit half-life sensitivity of the experiment is 2.9 × 1024 yr and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of 130Te and place a Bayesian lower bound on the decay half-life, T 0¿ > 2.7 × 1024 yr at 90 % C.L. Combining CUORE-0 data with the 19.75 kg·yr exposure 1/2 of 130Te from the Cuoricino experiment we obtain T0¿ > 4.0×1024 yr at 90% C.L. (Bayesian), the 1/2 most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, mßß < 270–760 me

    Status and prospects of discovery of 0νββ decay with the CUORE detector

    Get PDF
    In this contribution we present the achievements of the CUORE experiment so far. It is the first tonne-scale bolometric detector and it is in stable data taking since 2018. We reached to collect about 1800 kg×yr of exposure of which more than 1ton×year have been analysed. The CUORE detector is meant to search for the neutrinoless double β decay (0νββ) of the 130Te isotope. This is a beyond Standard Model process which could establish the nature of the neutrino to be Dirac or a Majorana particle. It is an alternative mode of the two-neutrinos double β decay, a rare decay which have been precisely measured by CUORE in the 130Te. We found no evidence of the 0νββ and we set a Bayesian lower limit of 2.2×1025yr on its half-life. The expertise achieved by CUORE set a milestone for any future bolometric detector, including CUPID, which is the planned next generation experiment searching for 0νββ with scintillating bolometers

    Reduction of Severe Acute Maternal Morbidity and Maternal Mortality in Thyolo District, Malawi: The Impact of Obstetric Audit

    Get PDF
    BACKGROUND: Critical incident audit and feedback are recommended interventions to improve the quality of obstetric care. To evaluate the effect of audit at district level in Thyolo, Malawi, we assessed the incidence of facility-based severe maternal complications (severe acute maternal morbidity (SAMM) and maternal mortality) during two years of audit and feedback. METHODOLOGY/PRINCIPAL FINDINGS: Between September 2007 and September 2009, we included all cases of maternal mortality and SAMM that occurred in Thyolo District Hospital, the main referral facility in the area, using validated disease-specific criteria. During two- to three-weekly audit sessions, health workers and managers identified substandard care factors. Resulting recommendations were implemented and followed up. Feedback was given during subsequent sessions. A linear regression analysis was performed on facility-based severe maternal complications. During the two-year study period, 386 women were included: 46 died and 340 sustained SAMM, giving a case fatality rate of 11.9%. Forty-five cases out of the 386 inclusions were audited in plenary with hospital staff. There was a reduction of 3.1 women with severe maternal complications per 1000 deliveries in the district health facilities, from 13.5 per 1000 deliveries in the beginning to 10.4 per 1000 deliveries at the end of the study period. The incidence of uterine rupture and major obstetric hemorrhage reduced considerably (from 3.5 to 0.2 and from 5.9 to 2.6 per 1000 facility deliveries respectively). CONCLUSIONS: Our findings indicate that audit and feedback have the potential to reduce serious maternal complications including maternal mortality. Complications like major hemorrhage and uterine rupture that require relatively straightforward intrapartum emergency management are easier to reduce than those which require uptake of improved antenatal care (eclampsia) or timely intravenous medication or HIV-treatment (peripartum infections)
    • …
    corecore