1,506 research outputs found

    Fourier Magnetic Imaging with Nanoscale Resolution and Compressed Sensing Speed-up using Electronic Spins in Diamond

    Full text link
    Optically-detected magnetic resonance using Nitrogen Vacancy (NV) color centres in diamond is a leading modality for nanoscale magnetic field imaging, as it provides single electron spin sensitivity, three-dimensional resolution better than 1 nm, and applicability to a wide range of physical and biological samples under ambient conditions. To date, however, NV-diamond magnetic imaging has been performed using real space techniques, which are either limited by optical diffraction to 250 nm resolution or require slow, point-by-point scanning for nanoscale resolution, e.g., using an atomic force microscope, magnetic tip, or super-resolution optical imaging. Here we introduce an alternative technique of Fourier magnetic imaging using NV-diamond. In analogy with conventional magnetic resonance imaging (MRI), we employ pulsed magnetic field gradients to phase-encode spatial information on NV electronic spins in wavenumber or k-space followed by a fast Fourier transform to yield real-space images with nanoscale resolution, wide field-of-view (FOV), and compressed sensing speed-up.Comment: 31 pages, 10 figure

    A giant adrenal lipoma presenting in a woman with chronic mild postprandial abdominal pain: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Adrenal lipomas are rare, small, benign, non-functioning tumors, which must be histopathologically differentiated from other tumors such as myelolipomas or liposarcomas. They are usually identified incidentally during autopsy, imaging, or laparotomy. Occasionally, they may present acutely due to complications such as abdominal pain from retroperitoneal bleeding, or systemic symptoms of infection. We report a giant adrenal lipoma (to the best of our knowledge, the second largest in the literature) clinically presenting with chronic mild postprandial pain.</p> <p>Case presentation</p> <p>A 54-year-old Caucasian woman presented several times over a period of 10 years to various emergency departments complaining of long-term mild postprandial abdominal pain. Although clinical examinations were unrevealing, an abdominal computed tomography scan performed at her most recent presentation led to the identification of a large lipoma of the left adrenal gland, which occupied most of the retroperitoneal space. Myelolipoma was ruled out due to the absence of megakaryocytes, immature leukocytes, or erythrocytes. Liposarcoma was ruled out due to the absence of lipoblasts. The size of the lipoma (16 × 14 × 7 cm) is, to the best of our knowledge, the second largest reported to date. After surgical resection, our patient was relieved of her symptoms and remains healthy six years postoperatively.</p> <p>Conclusion</p> <p>Physicians should be aware that differential diagnosis of mild chronic abdominal pain in patients presenting in emergency rooms may include large adrenal lipomas. When initial diagnostic investigation is not revealing, out-patient specialist evaluation should be planned to enable appropriate further investigations.</p

    Validation of the psychometric properties of the health-promoting lifestyle profile in a sample of Taiwanese women

    Get PDF
    PURPOSE: To examine the preliminary psychometric properties of the Chinese health-promoting lifestyle profile II (HPLP II) among Taiwanese women. METHODS: We conducted a secondary analysis of cross-sectional data from 137 middle-aged women in southern Taiwan. HPLP II reliability was estimated with Cronbach's alpha coefficient, and concurrent validity was estimated with Pearson's correlation between the HPLP II, the World Health Organization's abbreviated Quality of Life assessment (WHOQOL-BREF), perceived health, and demographic variables. Confirmatory factor analysis (CFA) evaluated construct validity. RESULTS: Initial CFA using a six-factor measurement model aligned with the original HPLP II, excepting the factor loading of one subsequently excluded item. CFA of the revised 51-item HPLP II yielded a good estimate of fit. Correlations between the revised instrument and the six subscales were acceptable >0.7. The Cronbach's alpha coefficient surpassed 0.7 for the revised instrument and six subscales ranged from 0.71 to 0.91. The relationships between the 51-item instrument, perceived health, WHOQOL-BREF domain scores, and demographic variables were also significantly positive. CONCLUSIONS: The revised HPLP II scale is appropriate to measure the health-promoting lifestyles of Taiwanese women.published_or_final_versionSpringer Open Choice, 21 Feb 201

    A search for the decay modes B+/- to h+/- tau l

    Get PDF
    We present a search for the lepton flavor violating decay modes B+/- to h+/- tau l (h= K,pi; l= e,mu) using the BaBar data sample, which corresponds to 472 million BBbar pairs. The search uses events where one B meson is fully reconstructed in one of several hadronic final states. Using the momenta of the reconstructed B, h, and l candidates, we are able to fully determine the tau four-momentum. The resulting tau candidate mass is our main discriminant against combinatorial background. We see no evidence for B+/- to h+/- tau l decays and set a 90% confidence level upper limit on each branching fraction at the level of a few times 10^-5.Comment: 15 pages, 7 figures, submitted to Phys. Rev.

    Evidence for an excess of B -> D(*) Tau Nu decays

    Get PDF
    Based on the full BaBar data sample, we report improved measurements of the ratios R(D(*)) = B(B -> D(*) Tau Nu)/B(B -> D(*) l Nu), where l is either e or mu. These ratios are sensitive to new physics contributions in the form of a charged Higgs boson. We measure R(D) = 0.440 +- 0.058 +- 0.042 and R(D*) = 0.332 +- 0.024 +- 0.018, which exceed the Standard Model expectations by 2.0 sigma and 2.7 sigma, respectively. Taken together, our results disagree with these expectations at the 3.4 sigma level. This excess cannot be explained by a charged Higgs boson in the type II two-Higgs-doublet model. We also report the observation of the decay B -> D Tau Nu, with a significance of 6.8 sigma.Comment: Expanded section on systematics, text corrections, improved the format of Figure 2 and included the effect of the change of the Tau polarization due to the charged Higg

    Search for the decay modes D^0 → e^+e^-, D^0 → μ^+μ^-, and D^0 → e^±μ∓

    Get PDF
    We present searches for the rare decay modes D^0→e^+e^-, D^0→μ^+μ^-, and D^0→e^±μ^∓ in continuum e^+e^-→cc events recorded by the BABAR detector in a data sample that corresponds to an integrated luminosity of 468  fb^(-1). These decays are highly Glashow–Iliopoulos–Maiani suppressed but may be enhanced in several extensions of the standard model. Our observed event yields are consistent with the expected backgrounds. An excess is seen in the D^0→μ^+μ^- channel, although the observed yield is consistent with an upward background fluctuation at the 5% level. Using the Feldman–Cousins method, we set the following 90% confidence level intervals on the branching fractions: B(D^0→e^+e^-)<1.7×10^(-7), B(D^0→μ^+μ^-) within [0.6,8.1]×10^(-7), and B(D^0→e^±μ^∓)<3.3×10^(-7)

    Accreting Millisecond X-Ray Pulsars

    Full text link
    Accreting Millisecond X-Ray Pulsars (AMXPs) are astrophysical laboratories without parallel in the study of extreme physics. In this chapter we review the past fifteen years of discoveries in the field. We summarize the observations of the fifteen known AMXPs, with a particular emphasis on the multi-wavelength observations that have been carried out since the discovery of the first AMXP in 1998. We review accretion torque theory, the pulse formation process, and how AMXP observations have changed our view on the interaction of plasma and magnetic fields in strong gravity. We also explain how the AMXPs have deepened our understanding of the thermonuclear burst process, in particular the phenomenon of burst oscillations. We conclude with a discussion of the open problems that remain to be addressed in the future.Comment: Review to appear in "Timing neutron stars: pulsations, oscillations and explosions", T. Belloni, M. Mendez, C.M. Zhang Eds., ASSL, Springer; [revision with literature updated, several typos removed, 1 new AMXP added

    Study of the reaction e^{+}e^{-} -->J/psi\pi^{+}\pi^{-} via initial-state radiation at BaBar

    Get PDF
    We study the process e+eJ/ψπ+πe^+e^-\to J/\psi\pi^{+}\pi^{-} with initial-state-radiation events produced at the PEP-II asymmetric-energy collider. The data were recorded with the BaBar detector at center-of-mass energies 10.58 and 10.54 GeV, and correspond to an integrated luminosity of 454 fb1\mathrm{fb^{-1}}. We investigate the J/ψπ+πJ/\psi \pi^{+}\pi^{-} mass distribution in the region from 3.5 to 5.5 GeV/c2\mathrm{GeV/c^{2}}. Below 3.7 GeV/c2\mathrm{GeV/c^{2}} the ψ(2S)\psi(2S) signal dominates, and above 4 GeV/c2\mathrm{GeV/c^{2}} there is a significant peak due to the Y(4260). A fit to the data in the range 3.74 -- 5.50 GeV/c2\mathrm{GeV/c^{2}} yields a mass value 4244±54244 \pm 5 (stat) ±4 \pm 4 (syst)MeV/c2\mathrm{MeV/c^{2}} and a width value 11415+16114 ^{+16}_{-15} (stat)±7 \pm 7(syst)MeV\mathrm{MeV} for this state. We do not confirm the report from the Belle collaboration of a broad structure at 4.01 GeV/c2\mathrm{GeV/c^{2}}. In addition, we investigate the π+π\pi^{+}\pi^{-} system which results from Y(4260) decay
    corecore