67 research outputs found

    Measurements of V/STOL aircraft noise mechanisms using pressure cross-correlation techniques in a reverberant wind tunnel

    Get PDF
    A 3.8 cm. model jet was operated in a wind tunnel with cross-flow in order to determine the effect on jet noise radiated characteristics. A method was developed for the determination of noise radiating characteristics of sources within reverberant wind tunnels; cross-correlation measurements were used. The averaging time in the cross-correlation is determined by the amount of background noise within the wind tunnel. It was found that cross-flow increases the radiated noise by 10 db. There was some indication of downstream radiation exceeding the sideline radiation

    Aerosound from corner flow and flap flow

    Get PDF
    Noise generation at the edge of a wing flap is analyzed. The phenomenon as a single vortex moving around a corner in an incompressible, potential flow is modelled. Vortex image retarding effects are proposed as an explanation for small Strouhal numbers. The model surface pressures, sound pressures (using Curle's theory), and Mach number dependencies agree with wind tunnel experiments. A double pressure peak is found in the model (credited to image action) which is qualitatively similar to measured sound correlations. Incompressible flow aerosound calculations are discussed. The effects of a series of vortices moving in the same idealized potential flow are also studied. The vortices are assumed to be statistically independent so their intensities can be added. The frequency of appearance of the vortices are determined from measurements. Diffraction effects caused by the presence of the wing near the dipole sound radiators on the flap surfaces are included

    Auditory and Visual Health after Ten Years of Exposure to Metal-on-Metal Hip Prostheses: A Cross-Sectional Study Follow Up

    Get PDF
    Case reports of patients with mal-functioning metal-on-metal hip replacement (MoMHR) prostheses suggest an association of elevated circulating metal levels with visual and auditory dysfunction. However, it is unknown if this is a cumulative exposure effect and the impact of prolonged low level exposure, relevant to the majority of patients with a well-functioning prosthesis, has not been studied. Twenty four male patients with a well-functioning MoMHR and an age and time since surgery matched group of 24 male patients with conventional total hip arthroplasty (THA) underwent clinical and electrophysiological assessment of their visual and auditory health at a mean of ten years after surgery. Median circulating cobalt and chromium concentrations were higher in patients after MoMHR versus those with THA (P<0.0001), but were within the Medicines and Healthcare Products Regulatory Agency (UK) investigation threshold. Subjective auditory tests including pure tone audiometric and speech discrimination findings were similar between groups (P>0.05). Objective assessments, including amplitude and signal-to-noise ratio of transient evoked and distortion product oto-acoustic emissions (TEOAE and DPOAE, respectively), were similar for all the frequencies tested (P>0.05). Auditory brainstem responses (ABR) and cortical evoked response audiometry (ACR) were also similar between groups (P>0.05). Ophthalmological evaluations, including self-reported visual function by visual functioning questionnaire, as well as binocular low contrast visual acuity and colour vision were similar between groups (P>0.05). Retinal nerve fibre layer thickness and macular volume measured by optical coherence tomography were also similar between groups (P>0.05). In the presence of moderately elevated metal levels associated with well-functioning implants, MoMHR exposure does not associate with clinically demonstrable visual or auditory dysfunction

    Documenting the Recovery of Vascular Services in European Centres Following the Initial COVID-19 Pandemic Peak: Results from a Multicentre Collaborative Study

    Get PDF
    Objective: To document the recovery of vascular services in Europe following the first COVID-19 pandemic peak. Methods: An online structured vascular service survey with repeated data entry between 23 March and 9 August 2020 was carried out. Unit level data were collected using repeated questionnaires addressing modifications to vascular services during the first peak (March – May 2020, “period 1”), and then again between May and June (“period 2”) and June and July 2020 (“period 3”). The duration of each period was similar. From 2 June, as reductions in cases began to be reported, centres were first asked if they were in a region still affected by rising cases, or if they had passed the peak of the first wave. These centres were asked additional questions about adaptations made to their standard pathways to permit elective surgery to resume. Results: The impact of the pandemic continued to be felt well after countries’ first peak was thought to have passed in 2020. Aneurysm screening had not returned to normal in 21.7% of centres. Carotid surgery was still offered on a case by case basis in 33.8% of centres, and only 52.9% of centres had returned to their normal aneurysm threshold for surgery. Half of centres (49.4%) believed their management of lower limb ischaemia continued to be negatively affected by the pandemic. Reduced operating theatre capacity continued in 45.5% of centres. Twenty per cent of responding centres documented a backlog of at least 20 aortic repairs. At least one negative swab and 14 days of isolation were the most common strategies used for permitting safe elective surgery to recommence. Conclusion: Centres reported a broad return of services approaching pre-pandemic “normal” by July 2020. Many introduced protocols to manage peri-operative COVID-19 risk. Backlogs in cases were reported for all major vascular surgeries

    A new treatment of rough surface scattering

    No full text

    Equilibrium characteristics of nearly normal turbulence

    No full text

    Reflection of Plane‐Polarized, Electromagnetic Radiation from an Echelette Diffraction Grating

    Full text link
    A variational method is used to calculate the distribution of energy reflected from an echelette diffraction grating. Experiments performed using a klystron generating 3.2‐cm electromagnetic waves which impinge upon a large scale grating agree with the calculations to within a few percent, the error being that expected from the variational formulation.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/69709/2/JAPIAU-28-2-216-1.pd
    corecore