156 research outputs found

    A characteristics framework for Semantic Information Systems Standards

    Get PDF
    Semantic Information Systems (IS) Standards play a critical role in the development of the networked economy. While their importance is undoubted by all stakeholders—such as businesses, policy makers, researchers, developers—the current state of research leaves a number of questions unaddressed. Terminological confusion exists around the notions of “business semantics”, “business-to-business interoperability”, and “interoperability standards” amongst others. And, moreover, a comprehensive understanding about the characteristics of Semantic IS Standards is missing. The paper addresses this gap in literature by developing a characteristics framework for Semantic IS Standards. Two case studies are used to check the applicability of the framework in a “real-life” context. The framework lays the foundation for future research in an important field of the IS discipline and supports practitioners in their efforts to analyze, compare, and evaluate Semantic IS Standard

    Size and Shape Distributions of Primary Crystallites in Titania Aggregates

    Get PDF
    The primary crystallite size of titania powder relates to its properties in a number of applications. Transmission electron microscopy was used in this interlaboratory comparison (ILC) to measure primary crystallite size and shape distributions for a commercial aggregated titania powder. Data of four size descriptors and two shape descriptors were evaluated across nine laboratories. Data repeatability and reproducibility was evaluated by analysis of variance. One-third of the laboratory pairs had similar size descriptor data, but 83% of the pairs had similar aspect ratio data. Scale descriptor distributions were generally unimodal and were well-described by lognormal reference models. Shape descriptor distributions were multi-modal but data visualization plots demonstrated that the Weibull distribution was preferred to the normal distribution. For the equivalent circular diameter size descriptor, measurement uncertainties of the lognormal distribution scale and width parameters were 9.5% and 22%, respectively. For the aspect ratio shape descriptor, the measurement uncertainties of the Weibull distribution scale and width parameters were 7.0% and 26%, respectively. Both measurement uncertainty estimates and data visualizations should be used to analyze size and shape distributions of particles on the nanoscale

    Distortion in a 7xxx aluminum alloy during liquid phase sintering

    Get PDF
    The distortion in a sintered 7xxx aluminum alloy, Al-7Zn-2.5Mg-1Cu (wt. pct), has been investigated by sintering three rectangular bars in each batch at 893 K (620 °C) for 0 to 40 minutes in nitrogen, followed by air or furnace cooling. They were placed parallel to each other, equally spaced apart at 2 mm, with their long axes being perpendicular to the incoming nitrogen flow. Pore evolution in each sample during isothermal sintering was examined metallographically. The compositional changes across sample mid-cross section and surface layers were analyzed using energy dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy depth profiling, respectively. The two outer samples bent toward the middle one, while the middle sample was essentially distortion free after sintering. The distortion in the outer samples was a result of differential shrinkage between their outer and inner surfaces during isothermal sintering. The porous outer surface showed an enrichment of oxygen around the large pores as well as lower magnesium and zinc contents than the interior and inner surface of the same sample, while the inner surface was distinguished by the presence of AlN. The differential shrinkage was caused by different oxygen contents in local sintering atmosphere and unbalanced loss of magnesium and zinc between the outer and inner surfaces

    Biological response of an in vitro human 3D lung cell model exposed to brake wear debris varies based on brake pad formulation

    Get PDF
    Wear particles from automotive friction brake pads of various sizes, morphology, and chemical composition are significant contributors towards particulate matter. Knowledge concerning the potential adverse effects following inhalation exposure to brake wear debris is limited. Our aim was, therefore, to generate brake wear particles released from commercial low-metallic and non-asbestos organic automotive brake pads used in mid-size passenger cars by a full-scale brake dynamometer with an environmental chamber simulating urban driving and to deduce their potential hazard in vitro. The collected fractions were analysed using scanning electron microscopy via energy-dispersive X-ray spectroscopy (SEM-EDS) and Raman microspectroscopy. The biological impact of the samples was investigated using a human 3D multicellular model consisting of human epithelial cells (A549) and human primary immune cells (macrophages and dendritic cells) mimicking the human epithelial tissue barrier. The viability, morphology, oxidative stress, and (pro-)inflammatory response of the cells were assessed following 24 h exposure to similar to 12, similar to 24, and similar to 48 A mu g/cm(2) of non-airborne samples and to similar to 3.7 A mu g/cm(2) of different brake wear size fractions (2-4, 1-2, and 0.25-1 A mu m) applying a pseudo-air-liquid interface approach. Brake wear debris with low-metallic formula does not induce any adverse biological effects to the in vitro lung multicellular model. Brake wear particles from non-asbestos organic formulated pads, however, induced increased (pro-)inflammatory mediator release from the same in vitro system. The latter finding can be attributed to the different particle compositions, specifically the presence of anatase.Web of Science9272351233
    corecore