179 research outputs found

    Development of a CO2CO_2 cooling prototype for the CBM Silicon Tracking System

    Get PDF
    Traumatic brain injury (TBI) frequently occurs during childhood and adolescence with long-term neuropsychological and behavioral effects. Greater personal awareness of injury is associated with better outcomes. However, personal awareness is often assessed using ratings obtained from family members or significant others. Surprisingly, the accuracy of family-ratings compared with self-ratings has not been well studied in the TBI population. Thus, the purpose of this study was to examine self versus family-ratings of frontal dysfunction and secondly, the association between self/family reported frontal dysfunction and measured executive function outcomes. A total of 60 participants, approximately 10 years post-TBI, comprised 3 groups including; moderate/severe TBI (N=26; mean age 22.9, SD=3.0), mild TBI (N=20; mean age, 21.7, SD=2.7), and control (N=14: mean age, 21.6, SD=3.7). Neuropsychological testing was used to obtain domain scores for executive function and working memory/attention for each participant, and nominated family members and participants with TBI were asked to complete the Frontal Systems Behaviour Scale (FrSBe), consisting of three sub-scales; apathy, disinhibition, and executive dysfunction. Using the FrSBe there was no significant difference between the groups in executive function score, but the moderate/severe and mild groups had significantly lower working memory/attention scores compared with the control group (p<0.05). Repeated measures analysis of variance showed higher self-ratings on all sub-scales compared with family in each group (p<0.05). Scores on executive function and working memory/attention domains correlated with self, but not family reported executive dysfunction. Self-rated executive dysfunction explained 36% of the variance in executive function (p<0.001). While agreement between self-rated and family-rated total FrSBe scores was significant in all groups (p<0.001), our results showed that self-ratings were of higher predictive utility for executive functioning compared with family ratings. Further, at 10 years post-TBI, patients show greater awareness of deficits compared with family who rate consistently closer to the normal functioning range

    Acute Cardiac Failure due to Intra-Atrial Mass Caused by Zygomycetes in an Immunocompromised Paediatric Patient

    Get PDF
    Cardiac zygomycosis can be a critical condition with sudden onset of severe congestive heart failure followed by severe hemodynamic deterioration. We report a fatal course of disseminated fungal infection with a massive intra-atrial thrombosis caused by a zygomycete, in a five year old boy treated for acute lymphoblastic leukaemia. In addition, we discuss the literature concerning infections caused by zygomycetes involving the heart. Prognosis is poor. A high index of suspicion and an aggressive diagnostic and therapeutic approach with the prompt start of preemptive antifungal therapy are key factors to improve outcome

    Daily interruption of sedation in critically ill children:study protocol for a randomized controlled trial

    Get PDF
    BACKGROUND: In adult patients who are critically ill and mechanically ventilated, daily interruption of sedation (DSI) is an effective method of improving sedation management, resulting in a decrease of the duration of mechanical ventilation, the length of stay in the intensive care unit (ICU) and the length of stay in the hospital. It is a safe and effective approach and is common practice in adult ICUs. For critically ill children it is unknown if DSI is effective and feasible. The aim of this multicenter randomized controlled trial is to evaluate the safety and efficacy of daily sedation interruption in critically ill children. METHODS/DESIGN: Children between 0 and 18 years of age who require mechanical ventilation, with an expected duration of at least 48 h and need for sedative infusion, will be included. After enrollment patients will be randomly assigned to DSI in combination with protocolized sedation (intervention group) or protocolized continuous sedation (control group). A sedation protocol that contains an algorithm for increasing and weaning of sedatives and analgesics will be used. The sedative infusion will be restarted if the patient becomes uncomfortable or agitated according to the sedation protocol. The primary endpoint is the number of ventilator-free days at 28 days. TRIAL REGISTRATION: NTR203

    Isotopic Composition of Light Nuclei in Cosmic Rays: Results from AMS-01

    Get PDF
    The variety of isotopes in cosmic rays allows us to study different aspects of the processes that cosmic rays undergo between the time they are produced and the time of their arrival in the heliosphere. In this paper we present measurements of the isotopic ratios 2H/4He, 3He/4He, 6Li/7Li, 7Be/(9Be+10Be) and 10B/11B in the range 0.2-1.4 GeV of kinetic energy per nucleon. The measurements are based on the data collected by the Alpha Magnetic Spectrometer, AMS-01, during the STS-91 flight in 1998 June.Comment: To appear in ApJ. 12 pages, 11 figures, 6 table

    Enhancing cardiovascular artificial intelligence (AI) research in the Netherlands: CVON-AI consortium

    Get PDF
    Background Machine learning (ML) allows the exploration and progressive improvement of very complex high-dimensional data patterns that can be utilised to optimise specific classification and prediction tasks, outperforming traditional statistical approaches. An enormous acceleration of ready-to-use tools and artificial intelligence (AI) applications, shaped by the emergence, refinement, and application of powerful ML algorithms in several areas of knowledge, is ongoing. Although such progress has begun to permeate the medical sciences and clinical medicine, implementation in cardiovascular medicine and research is still in its infancy. Objectives To lay out the theoretical framework, purpose, and structure of a novel AI consortium. Methods We have established a new Dutch research consortium, the CVON-AI, supported by the Netherlands Heart Foundation, to catalyse and facilitate the development and utilisation of AI solutions for existing and emerging cardiovascular research initiatives and to raise AI awareness in the cardiovascular research community. CVON-AI will connect to previously established CVON consortia and apply a cloud-based AI platform to supplement their planned traditional data-analysis approach. Results A pilot experiment on the CVON-AI cloud was conducted using cardiac magnetic resonance data. It demonstrated the feasibility of the platform and documented excellent correlation between AI-generated ventricular function estimates as compared to expert manual annotations. The resulting AI solution was then integrated in a web application. Conclusion CVON-AI is a new consortium meant to facilitate the implementation and raise awareness of AI in cardiovascular research in the Netherlands. CVON-AI will create an accessible cloud-based platform for cardiovascular researchers, demonstrate the clinical applicability of AI, optimise the analytical methodology of other ongoing CVON consortia, and promote AI awareness through education and training.</p

    Performance of the LHCb vertex locator

    Get PDF
    The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 ÎŒm is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 ÎŒm for translations in the plane transverse to the beam. A primary vertex resolution of 13 ÎŒm in the transverse plane and 71 ÎŒm along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 ÎŒm is achieved for particles with transverse momentum greater than 1 GeV/c

    Search for antihelium in cosmic rays

    Get PDF
    The Alpha Magnetic Spectrometer (AMS) was flown on the space shuttle Discovery during flight STS-91 in a 51.7 degree orbit at altitudes between 320 and 390 km. A total of 2.86 * 10^6 helium nuclei were observed in the rigidity range 1 to 140 GV. No antihelium nuclei were detected at any rigidity. An upper limit on the flux ratio of antihelium to helium of < 1.1 * 10^-6 is obtained.Comment: 18 pages, Latex, 9 .eps figure
    • 

    corecore