183 research outputs found
Observation of Parity Nonconservation in Moller Scattering
We report a measurement of the parity-violating asymmetry in fixed target
electron-electron (Moller) scattering: A_PV = -175 +/- 30 (stat.) +/- 20
(syst.) parts per billion. This first direct observation of parity
nonconservation in Moller scattering leads to a measurement of the electron's
weak charge at low energy Q^e_W = -0.053 +/- 0.011. This is consistent with the
Standard Model expectation at the current level of precision:
sin^2\theta_W(M_Z)_MSbar = 0.2293 +/- 0.0024 (stat.) +/- 0.0016 (syst.) +/-
0.0006 (theory).Comment: Version 3 is the same as version 2. These versions contain minor text
changes from referee comments and a change in the extracted value of Q^e_W
and sin^2\theta_W due to a change in the theoretical calculation of the
bremsstrahulung correction (ref. 16
Precision Measurement of the Weak Mixing Angle in Moller Scattering
We report on a precision measurement of the parity-violating asymmetry in
fixed target electron-electron (Moller) scattering: A_PV = -131 +/- 14 (stat.)
+/- 10 (syst.) parts per billion, leading to the determination of the weak
mixing angle \sin^2\theta_W^eff = 0.2397 +/- 0.0010 (stat.) +/- 0.0008 (syst.),
evaluated at Q^2 = 0.026 GeV^2. Combining this result with the measurements of
\sin^2\theta_W^eff at the Z^0 pole, the running of the weak mixing angle is
observed with over 6 sigma significance. The measurement sets constraints on
new physics effects at the TeV scale.Comment: 4 pages, 2 postscript figues, submitted to Physical Review Letter
Recommended from our members
Recent Improvements in the SLC Positron System Performance
The positron system is very specific to the SLC in that the positrons are accelerated in the same linac as the electrons that produce them and the electrons with which they collide. Some of the difficulties in tuning this system to peak performance are thus unlikely to be encountered in future linear colliders, but many of the lessons learned in beam matching are useful for future machines. The design and commissioning of this system has been previously reported so we only briefly describe the major subsystems before detailing the tuning and diagnostics involved in optimizing the performance of the overall system
Recommended from our members
Recent Improvements in the SLC Positron System Performance
The positron system is very specific to the SLC in that the positrons are accelerated in the same linac as the electrons that produce them and the electrons with which they collide. Some of the difficulties in tuning this system to peak performance are thus unlikely to be encountered in future linear colliders, but many of the lessons learned in beam matching are useful for future machines. The design and commissioning of this system has been previously reported so we only briefly describe the major subsystems before detailing the tuning and diagnostics involved in optimizing the performance of the overall system
Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements
Radio Astronomy
Contains table of contents for Section 4 and reports on ten research projects.National Science Foundation Grant AST 90-22501Alfred P. Sloan FellowshipDavid and Lucile Packard Fellowship Award for Science and EngineeringNational Aeronautics and Space AdministrationNational Science Foundation Presidential Young Investigator AwardNational Aeronautics and Space Administration Grant NAGW-2310MIT Lincoln Laboratory Agreement BX-4975National Aeronautics and Space Administration/Goddard Space Flight Center Contract NAS 5-31276MIT Leaders for Manufacturing Progra
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.Comment: 10 pages, 5 figure
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
We have searched for periodic variations of the electronic recoil event rate
in the (2-6) keV energy range recorded between February 2011 and March 2012
with the XENON100 detector, adding up to 224.6 live days in total. Following a
detailed study to establish the stability of the detector and its background
contributions during this run, we performed an un-binned profile likelihood
analysis to identify any periodicity up to 500 days. We find a global
significance of less than 1 sigma for all periods suggesting no statistically
significant modulation in the data. While the local significance for an annual
modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and
the phase of the modulation disfavor a dark matter interpretation. The
DAMA/LIBRA annual modulation interpreted as a dark matter signature with
axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.Comment: 6 pages, 4 figure
Radio Astronomy
Contains table of contents for Section 4 and reports on ten research projects.National Science Foundation Grant AST 90-22501National Aeronautics and Space Administration Grant NAGW 1386National Science Foundation Presidential Young Investigator AwardDavid and Lucile Packard Fellowship for Science and EngineeringNational Aeronautics and Space Administration Grant NAGW-2310MIT Lincoln LaboratorySM Systems and Research CorporationNational Aeronautics and Space Administration/Goddard Space Flight Center Contract NAS 5-30791National Aeronautics and Space Administration/Goddard Space Flight Center Grant NAG 5-10MIT Leaders for Manufacturing Progra
- …