130 research outputs found

    Vertical Displacement of Bridges Using the SOFO System: a Fiber Optic Monitoring Method for Structures

    Get PDF

    Behavior of molecules and molecular ions near a field emitter

    Get PDF
    The cold emission of particles from surfaces under intense electric fields is a process which underpins a variety of applications including atom probe tomography (APT), an analytical microscopy technique with near-atomic spatial resolution. Increasingly relying on fast laser pulsing to trigger the emission, APT experiments often incorporate the detection of molecular ions emitted from the specimen, in particular from covalently or ionically bonded materials. Notably, it has been proposed that neutral molecules can also be emitted during this process. However, this remains a contentious issue. To investigate the validity of this hypothesis, a careful review of the literature is combined with the development of new methods to treat experimental APT data, the modeling of ion trajectories, and the application of density-functional theory simulations to derive molecular ion energetics. It is shown that the direct thermal emission of neutral molecules is extremely unlikely. However, neutrals can still be formed in the course of an APT experiment by dissociation of metastable molecular ions

    A Photonic Atom Probe coupling 3D Atomic Scale Analysis with in situ Photoluminescence Spectroscopy

    Full text link
    Laser enhanced field evaporation of surface atoms in Laser-assisted Atom Probe Tomography (La-APT) can simultaneously excite phtotoluminescence in semiconductor or insulating specimens. An atom probe equipped with appropriate focalization and collection optics has been coupled with an in-situ micro-Photoluminescence ({\mu}PL) bench that can be operated during APT analysis. The Photonic Atom Probe instrument we have developped operates at frequencies up to 500 kHz and is controlled by 150 fs laser pulses tunable in energy in a large spectral range (spanning from deep UV to near IR). Micro-PL spectroscopy is performed using a 320 mm focal length spectrometer equipped with a CCD camera for time-integrated and with a streak camera for time-resolved acquisitions. An exemple of application of this instrument on a multi-quantum well oxide heterostructure sample illustrates the potential of this new generation of tomographic atom probe.Comment: 22 pages, 4 figures. The following article has been accepted by the Review of Scientific Instruments. After it is published, it will be found at https://publishing.aip.org/resources/librarians/products/journals

    Three-dimensional nanoscale study of Al segregation and quantum dot formation in GaAs/AlGaAs core-shell nanowires

    Get PDF
    GaAs/Al-GaAs core-shell nanowires fabricated by molecular beam epitaxy contain quantum confining structures susceptible of producing narrow photoluminescence (PL) and single photons. The nanoscale chemical mapping of these structures is analyzed in 3D by atom probe tomography (APT). The study allows us to confirm that Al atoms tend to segregate within the AlGaAs shells towards the vertices of the hexagons defining the nanowire cross section. We also find strong alloy fluctuations remaining AlGaAs shell, leading occasionally to the formation of quantum dots (QDs). The PL emission energies predicted in the framework of a 3D effective mass model for a QD analyzed by APT and the PL spectra measured on other nanowires from the same growth batch are consistent within the experimental uncertainties. (C) 2014 AIP Publishing LLC

    The Shift from Local to Global Visual Processing in 6-Year-Old Children Is Associated with Grey Matter Loss

    Get PDF
    International audienceBackground: A real-world visual scene consists of local elements (e.g. trees) that are arranged coherently into a global configuration (e.g. a forest). Children show psychological evolution from a preference for local visual information to an adult-like preference for global visual information, with the transition in visual preference occurring around 6 years of age. The brain regions involved in this shift in visual preference have not been described. Methods and Results: We used voxel-based morphometry (VBM) to study children during this developmental window to investigate changes in gray matter that underlie the shift from a bias for local to global visual information. Six-year-old children were assigned to groups according to their judgment on a global/local task. The first group included children who still presented with local visual processing biases, and the second group included children who showed global visual processing biases. VBM results indicated that compared to children with local visual processing biases, children with global visual processing biases had a loss of gray matter in the right occipital and parietal visuospatial areas. Conclusions: These anatomical findings are in agreement with previous findings in children with neurodevelopmental disorders and represent the first structural identification of brain regions that allow healthy children to develop a global perception of the visual world

    Developing atom probe tomography of phyllosilicates in preparation for extra-terrestrial sample return

    Get PDF
    Hydrous phyllosilicate minerals, including the serpentine subgroup, are likely to be major constituents of material that will be bought back to Earth by missions to Mars and to primitive asteroids Ryugu and Bennu. Small quantities (< 60 g) of micrometre sized, internally heterogeneous material will be available for study, requiring minimally destructive techniques. Many conventional methods are unsuitable for phyllosilicates as they are typically finely crystalline and electron beam sensitive resulting in amorphisation and dehydration. New tools will be required for nanoscale characterisation of these precious extra‐terrestrial samples. Here we test the effectiveness of atom probe tomography (APT) for this purpose. Using lizardite from the Ronda peridotite, Spain, as a terrestrial analogue, we outline an effective analytical protocol to extract nanoscale chemical and structural measurements of phyllosilicates. The potential of APT is demonstrated by the unexpected finding that the Ronda lizardite contains SiO‐rich nanophases, consistent with opaline silica that formed as a by‐product of the serpentinisation of olivine. Our new APT approach unlocks previously unobservable nanominerals and nanostructures within phyllosilicates owing to resolution limitations of more established imaging techniques. APT will provide unique insights into the processes and products of water/rock interaction on Earth, Mars and primitive asteroids
    • 

    corecore