872 research outputs found

    MRI in soils: determination of water concent changes due to root water uptake by means of a multi-slice-multi-echo sequence (MSME)

    Get PDF
    Root water uptake by ricinus communis (castor bean) in fine sand was investigated using MRI with multiecho sampling. Before starting the experiments the plants germinated and grew for 3 weeks in a cylindrical container with a diameter of 9 cm. Immediately before the MRI experiments started, the containers were water-saturated and sealed, so water content changes were only caused by root water uptake. In continuation of a preceding work, where we applied SPRITE we tested a multi-echo multi-slice sequence (MSME). In this approach, the water content was imaged by setting TE = 6.76 ms and nE = 128 with an isotropic resolution of 3.1mm. We calculated the water content maps by biexponential fitting of the multi-slice echo train data and normalisation on reference cuvettes filled with glass beads and 1 mM NiCl2 solution. The water content determination was validated by comparing to mean gravimetric water content measurements. By coregistration with the root architecture, visualised by a 3D fast spin echo sequence (RARE), we conclude that the largest water content changes occurred in the neighbourhood of the roots and in the upper layers of the soil

    Reproducibility and validity of a diet quality index for children assessed using a FFQ

    Get PDF
    The diet quality index (DQI) for preschool children is a new index developed to reflect compliance with four main food-based dietary guidelines for preschool children in Flanders. The present study investigates: (1) the validity of this index by comparing DQI scores for preschool children with nutrient intakes, both of which were derived from 3d estimated diet records; (2) the reproducibility of the DQI for preschoolers based on a parentally reported forty-seven-item FFQ DQI, which was repeated after 5 weeks; (3) the relative validity of the FFQ DQI with 3d record DQI scores as reference. The study sample included 510 and 58 preschoolers (2-5-6.5 years) for validity and reproducibility analyses, respectively. Increasing 3d record DQI scores were associated with decreasing consumption of added sugars, and increasing intakes of fibre, water, Ca and many micronutrients. Mean FFQ DQI test-retest scores were not significantly different: 72 (so 11) v. 71 (Si) 10) (P-=0-218) out of a maximum of 100. Mean 3d record DQI score (66 (so 10)) was significantly lower than mean FFQ DQI (71 (so 10);

    Void conditions and potential for mould growth in insulated and uninsulated suspended timber ground floors

    Get PDF
    PURPOSE: Millions of properties have suspended timber ground floors globally, with around ten million in the UK alone. However, it is unknown what the floor void conditions are, nor the effect of insulating such floors. Upgrading floors changes the void conditions, which might increase or decrease moisture build-up and mould and fungal growth. The purpose of this paper is to provide a review of the current global evidence and present the results of in situ monitoring of 15 UK floor voids. DESIGN/METHODOLOGY/APPROACH: An extensive literature review on the moisture behaviour in both uninsulated and insulated suspended timber crawl spaces is supplemented with primary data of a monitoring campaign during different periods between 2012 and 2015. Air temperature and relative humidity sensors were placed in different floor void locations. Where possible, crawl spaces were visually inspected. FINDINGS: Comparison of void conditions to mould growth thresholds highlights that a large number of monitored floor voids might exceed the critical ranges for mould growth, leading to potential occupant health impacts if mould spores transfer into living spaces above. A direct comparison could not be made between insulated and uninsulated floors in the sample due to non-random sampling and because the insulated floors included historically damp floors. The study also highlighted that long-term monitoring over all seasons and high-resolution monitoring and inspection are required; conditions in one location are not representative of conditions in other locations. ORIGINALITY/VALUE: This study presents the largest UK sample of monitored floors, evaluated using a review of current evidence and comparison with literature thresholds

    Multiscale Soil Investigations: Physical Concepts And Mathematical Techniques

    Get PDF
    Soil variability has often been considered to be composed of “functional” (explained) variations plus random fl uctuations or noise. However, the distinction between these two components is scale dependent because increasing the scale of observation almost always reveals structure in the noise (Burrough, 1983). Soils can be seen as the result of spatial variation operating over several scales, indicating that factors infl uencing spatial variability differ with scale. Th is observation points to variability as a key soil attribute that should be studied
    • …
    corecore