644 research outputs found

    Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating

    Get PDF
    AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.

    Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating

    Get PDF
    AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.

    Immunogenicity and safety of yellow fever vaccination for 102 HIV-infected patients

    Get PDF
    BACKGROUND: Yellow fever vaccine (17DV) has been investigated incompletely in human immunodeficiency virus (HIV)-infected patients, and adequate immunogenicity and safety are of concern in this population. METHODS: In the Swiss HIV Cohort Study, we identified 102 patients who received 17DV while they were HIV infected. We analyzed neutralization titers (NTs) after 17DV administration using the plaque reduction neutralization test. NTs of 1:>or=10 were defined as reactive, and those of 1:<10 were defined as nonreactive, which was considered to be nonprotective. The results were compared with data for HIV-uninfected individuals. Serious adverse events were defined as hospitalization or death within 6 weeks after receipt of 17DV. RESULTS: At the time of 17DV administration, the median CD4 cell count was 537 cells/mm(3) (range, 11-1730 cells/mm(3)), and the HIV RNA level was undetectable in 41 of 102 HIV-infected patients. During the first year after vaccination, fewer HIV-infected patients (65 [83%] of 78; P = .01) than HIV-uninfected patients revealed reactive NTs, and their NTs were significantly lower (P < .001) than in HIV-uninfected individuals. Eleven patients with initially reactive NTs lost these reactive NTs <or= 5 years after vaccination. Higher NTs during the first year after vaccination were associated with undetectable HIV RNA levels, increasing CD4 cell count, and female sex. We found no serious adverse events after 17DV administration among HIV-infected patients. CONCLUSION: Compared with HIV-uninfected individuals, HIV-infected patients respond to 17DV with lower reactive NTs, more often demonstrate nonprotective NTs, and may experience a more rapid decline in NTs during follow-up. Vaccination with 17DV appears to be safe in HIV-infected individuals who have high CD4 cell counts, although rate of serious adverse events of up to 3% cannot be exclude

    Short-range repulsion and isospin dependence in the KN system

    Get PDF
    The short-range properties of the KN interaction are studied within the meson-exchange model of the Juelich group. Specifically, dynamical explanations for the phenomenological short-range repulsion, required in this model for achieving agreement with the empirical KN data, are explored. Evidence is found that contributions from the exchange of a heavy scalar-isovector meson (a_0(980)) as well as from genuine quark-gluon exchange processes are needed. Taking both mechanisms into account a satisfactory description of the KN phase shifts can be obtained without resorting to phenomenological pieces.Comment: 26 pages, 5 figure

    Excited Baryons in Lattice QCD

    Get PDF
    We present first results for the masses of positive and negative parity excited baryons calculated in lattice QCD using an O(a^2)-improved gluon action and a fat-link irrelevant clover (FLIC) fermion action in which only the irrelevant operators are constructed with APE-smeared links. The results are in agreement with earlier calculations of N^* resonances using improved actions and exhibit a clear mass splitting between the nucleon and its chiral partner. An correlation matrix analysis reveals two low-lying J^P=(1/2)^- states with a small mass splitting. The study of different Lambda interpolating fields suggests a similar splitting between the lowest two Lambda1/2^- octet states. However, the empirical mass suppression of the Lambda^*(1405) is not evident in these quenched QCD simulations, suggesting a potentially important role for the meson cloud of the Lambda^*(1405) and/or a need for more exotic interpolating fields.Comment: Correlation matrix analysis performed. Increased to 400 configurations. 22 pages, 13 figures, 15 table

    Coherent diffraction of single Rice Dwarf virus particles using hard X-rays at the Linac Coherent Light Source

    Get PDF
    Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a wellcharacterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 mu m diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 angstrom ngstrom were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.11Ysciescopu
    corecore