51 research outputs found
Controle integrado de plantas daninhas em agroecossistemas cotonicolas.
bitstream/item/33329/1/CONTOLE-INTEGRADO.pd
The in-plane paraconductivity in La_{2-x}Sr_xCuO_4 thin film superconductors at high reduced-temperatures: Independence of the normal-state pseudogap
The in-plane resistivity has been measured in (LSxCO)
superconducting thin films of underdoped (), optimally-doped
() and overdoped () compositions. These films were grown
on (100)SrTiO substrates, and have about 150 nm thickness. The in-plane
conductivity induced by superconducting fluctuations above the superconducting
transition (the so-called in-plane paraconductivity, ) was
extracted from these data in the reduced-temperature range
10^{-2}\lsim\epsilon\equiv\ln(T/\Tc)\lsim1. Such a
was then analyzed in terms of the
mean-field--like Gaussian-Ginzburg-Landau (GGL) approach extended to the
high- region by means of the introduction of a total-energy cutoff,
which takes into account both the kinetic energy and the quantum localization
energy of each fluctuating mode. Our results strongly suggest that at all
temperatures above Tc, including the high reduced-temperature region, the
doping mainly affects in LSxCO thin films the normal-state properties and that
its influence on the superconducting fluctuations is relatively moderate: Even
in the high- region, the in-plane paraconductivity is found to be
independent of the opening of a pseudogap in the normal state of the underdoped
films.Comment: 35 pages including 10 figures and 1 tabl
Defect Localization By an Extended Laser Source on a Hemisphere
The primary goal of this study is to localize a defect (cavity) in a curved geometry. Curved topologies exhibit multiple resonances and the presence of hotspots for acoustic waves. Launching acoustic waves along a specific direction e.g. by means of an extended laser source reduces the complexity of the scattering problem. We performed experiments to demonstrate the use of a laser line source and verified the experimental results in FEM simulations. In both cases, we could locate and determine the size of a pit in a steel hemisphere which allowed us to visualize the defect on a 3D model of the sample. Such an approach could benefit patients by enabling contactless inspection of acetabular cups. © 2021, The Author(s).Open access funded by University of Helsinki Library
Manual and automatic image analysis segmentation methods for blood flow studies in microchannels
In blood flow studies, image analysis plays an extremely important role to examine raw data obtained by high-speed video microscopy systems. This work shows different ways to process the images which contain various blood phenomena happening in microfluidic devices and in microcirculation. For this purpose, the current methods used for tracking red blood cells (RBCs) flowing through a glass capillary and techniques to measure the cell-free layer thickness in different kinds of microchannels will be presented. Most of the past blood flow experimental data have been collected and analyzed by means of manual methods, that can be extremely reliable, but they are highly time-consuming, user-intensive, repetitive, and the results can be subjective to user-induced errors. For this reason, it is crucial to develop image analysis methods able to obtain the data automatically. Concerning automatic image analysis methods for individual RBCs tracking and to measure the well known microfluidic phenomena cell-free layer, two developed methods are presented and discussed in order to demonstrate their feasibility to obtain accurate data acquisition in such studies. Additionally, a comparison analysis between manual and automatic methods was performed.This project has been funded by Portuguese national funds of FCT/MCTES (PIDDAC)
through the base funding from the following research units: UIDB/00532/2020 (Transport Phenomena Research Center—CEFT), UIDB/04077/2020 (Mechanical Engineering and Resource Sustainability Center—MEtRICs), UIDB/00690/2020 (CIMO). The authors are also grateful for the partial funding of FCT through the projects, NORTE-01-0145-FEDER-029394 (PTDC/EMD-EMD/29394/2017)
and NORTE-01-0145-FEDER-030171 (PTDC/EMD-EMD/30171/2017) funded by COMPETE2020,
NORTE2020, PORTUGAL2020 and FEDER. D. Bento acknowledges the PhD scholarship SFRH/BD/
91192/2012 granted by FCT
Emery-Dreifuss muscular dystrophy Type 1 is associated with a high risk of malignant ventricular arrhythmias and end-stage heart failure
\ua9 2023 The Author(s). Published by Oxford University Press on behalf of the European Society of Cardiology.Background and Aims: Emery-Dreifuss muscular dystrophy (EDMD) is caused by variants in EMD (EDMD1) and LMNA (EDMD2). Cardiac conduction defects and atrial arrhythmia are common to both, but LMNA variants also cause end-stage heart failure (ESHF) and malignant ventricular arrhythmia (MVA). This study aimed to better characterize the cardiac complications of EMD variants. Methods: Consecutively referred EMD variant-carriers were retrospectively recruited from 12 international cardiomyopathy units. MVA and ESHF incidences in male and female variant-carriers were determined. Male EMD variant-carriers with a cardiac phenotype at baseline (EMDCARDIAC) were compared with consecutively recruited male LMNA variant-carriers with a cardiac phenotype at baseline (LMNACARDIAC). Results: Longitudinal follow-up data were available for 38 male and 21 female EMD variant-carriers [mean (SD) ages 33.4 (13.3) and 43.3 (16.8) years, respectively]. Nine (23.7%) males developed MVA and five (13.2%) developed ESHF during a median (inter-quartile range) follow-up of 65.0 (24.3-109.5) months. No female EMD variant-carrier had MVA or ESHF, but nine (42.8%) developed a cardiac phenotype at a median (inter-quartile range) age of 58.6 (53.2-60.4) years. Incidence rates for MVA were similar for EMDCARDIAC and LMNACARDIAC (4.8 and 6.6 per 100 person-years, respectively; log-rank P =. 49). Incidence rates for ESHF were 2.4 and 5.9 per 100 person-years for EMDCARDIAC and LMNACARDIAC, respectively (log-rank P =. 09). Conclusions: Male EMD variant-carriers have a risk of progressive heart failure and ventricular arrhythmias similar to that of male LMNA variant-carriers. Early implantable cardioverter defibrillator implantation and heart failure drug therapy should be considered in male EMD variant-carriers with cardiac disease
Emery-Dreifuss Muscular Dystrophy 1 is associated with high risk of malignant ventricular arrhythmias and end-stage heart failure.
BACKGROUND AND AIMS
Emery-Dreifuss muscular dystrophy (EDMD) is caused by variants in EMD (EDMD1) and LMNA (EDMD2). Cardiac conduction defects and atrial arrhythmia are common to both, but LMNA variants also cause end-stage heart failure (ESHF) and malignant ventricular arrhythmia (MVA). This study aimed to better characterise the cardiac complications of EMD variants.
METHODS
Consecutively referred EMD variant-carriers were retrospectively recruited from 12 international cardiomyopathy units. MVA and ESHF incidence in male and female variant-carriers was determined. Male EMD variant-carriers with a cardiac phenotype at baseline (EMDCARDIAC) were compared to consecutively recruited male LMNA variant-carriers with a cardiac phenotype at baseline (LMNACARDIAC).
RESULTS
Longitudinal follow-up data were available for 38 male and 21 female EMD variant-carriers (mean [SD] ages 33.4 [13.3] and 43.3 [16.8] years, respectively). Nine (23.6%) males developed MVA and five (13.2%) developed ESHF during a median [IQR] follow-up of 65.0 [24.3, 109.5] months. No female EMD variant-carrier had MVA or ESHF, but nine (42.8%) developed a cardiac phenotype at a median [IQR] age of 58.6 [53.2, 60.4] years. Incidence rates for MVA were similar for EMDCARDIAC and LMNACARDIAC (4.8 and 6.6 per 100 person-years, respectively; log-rank p = 0.49). Incidence rates for ESHF were 2.4 and 5.9 per 100 person-years for EMDCARDIAC and LMNACARDIAC, respectively (log-rank p = 0.09).
CONCLUSIONS
Male EMD variant-carriers have a risk of progressive heart failure and ventricular arrhythmias similar to that of male LMNA variant-carriers. Early implantable cardioverter defibrillator implantation and heart failure drug therapy should be considered in male EMD variant-carriers with cardiac disease.The work reported in this publication was funded by: a British Heart
Foundation Clinical Research Training Fellowship to D.E.C. (FS/CRTF/
20/24022); a British Heart Foundation Clinical Research Training fellowship to A.P. (FS/18/82/34024); The Ministry of Health, Italy, project
RC-2022-2773270 to E.B.; the National Institutes of Health (NIH)
(R01HL69071, R01HL116906, R01HL147064, NIH/NCATS UL1
TR002535, and UL1 TR001082) to L.M.; and support from the Rose
Foundation for K.M.S
Tuberculosis cure rates and the ETR.Net: investigating the quality of reporting treatment outcomes from primary healthcare facilities in Mpumalanga province, South Africa
Screening mutations in myosin binding protein C3 gene in a cohort of patients with Hypertrophic Cardiomyopathy
<p>Abstract</p> <p>Background</p> <p><it>MyBPC3 </it>mutations are amongst the most frequent causes of hypertrophic cardiomyopathy, however, its prevalence varies between populations. They have been associated with mild and late onset disease expression. Our objectives were to establish the prevalence of <it>MyBPC3 </it>mutations and determine their associated clinical characteristics in our patients.</p> <p>Methods</p> <p>Screening by Single Strand Conformation Polymorphisms (SSCP) and sequencing of the fragments with abnormal motility of the <it>MyBPC3 </it>gene in 130 unrelated consecutive HCM index cases. Genotype-Phenotype correlation studies were done in positive families.</p> <p>Results</p> <p>16 mutations were found in 20 index cases (15%): 5 novel [D75N, V471E, Q327fs, IVS6+5G>A (homozygous), and IVS11-9G>A] and 11 previously described [A216T, R495W, R502Q (2 families), E542Q (3 families), T957S, R1022P (2 families), E1179K, K504del, K600fs, P955fs and IVS29+5G>A]. Maximum wall thickness and age at time of diagnosis were similar to patients with <it>MYH7 </it>mutations [25(7) vs. 27(8), p = 0.16], [46(16) vs. 44(19), p = 0.9].</p> <p>Conclusions</p> <p>Mutations in <it>MyBPC3 </it>are present in 15% of our hypertrophic cardiomyopathy families. Severe hypertrophy and early expression are compatible with the presence of <it>MyBPC3 </it>mutations. The genetic diagnosis not only allows avoiding clinical follow up of non carriers but it opens new possibilities that includes: to take preventive clinical decisions in mutation carriers than have not developed the disease yet, the establishment of genotype-phenotype relationship, and to establish a genetic diagnosis routine in patients with familial HCM.</p
- …