185 research outputs found

    Scatter-free breast imaging using a monochromator coupled to a pixellated spectroscopic detector

    Get PDF
    This project uses the combination of a spectroscopic detector and a monochromator to produce scatter free images for use in mammography. Reducing scatter is vital in mammography, where typical structures have either low contrast or small dimensions. The typical method to reduce scatter is the anti-scatter grid, which has the drawback of absorbing a fraction of the primary beam as well as scattered radiation. An increase in the dose is then required in order to compensate. Compton-scattered X-rays have lower energy than the primary beam. When using a monochromatic beam and a spectroscopic detector the scattered beam will appear at lower energies than the primary beam in the detected spectrum. Therefore if the spectrum of the detected X-rays is available, the scattered component can be windowed out of the spectrum, essentially producing a scatter free image. The monochromator used in this study is made from a Highly Orientated Pyrolytic Graphite (HOPG) crystal with a mosaic spread of 0.4°±0.1°. The detector is a pixellated spectroscopic detector that is made from a 2 cm x 2 cm x 0.1 cm CdTe crystal with a pixel pitch of 250 μm and an energy resolution of 0.8 keV at 59.5 keV. This work presents the characterisation of the monochromator and initial imaging data. The work shows a contrast increase of 20% with the removal of the low energy Compton scattered X-rays. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only

    Optimization of K-edge subtraction imaging using a pixellated spectroscopic detector

    Full text link
    Conventional K-edge subtraction imaging is based around the acquisition of two separate images at energies respectively below and above the K-edge of a contrast agent. This implies increased patient dose with respect to a conventional procedure and potentially incorrect image registration due to patient motion. © 2012 IEEE

    An empirical investigation of dance addiction

    Get PDF
    Although recreational dancing is associated with increased physical and psychological well-being, little is known about the harmful effects of excessive dancing. The aim of the present study was to explore the psychopathological factors associated with dance addiction. The sample comprised 447 salsa and ballroom dancers (68% female, mean age: 32.8 years) who danced recreationally at least once a week. The Exercise Addiction Inventory (Terry, Szabo, & Griffiths, 2004) was adapted for dance (Dance Addiction Inventory, DAI). Motivation, general mental health (BSI-GSI, and Mental Health Continuum), borderline personality disorder, eating disorder symptoms, and dance motives were also assessed. Five latent classes were explored based on addiction symptoms with 11% of participants belonging to the most problematic class. DAI was positively associated with psychiatric distress, borderline personality and eating disorder symptoms. Hierarchical linear regression model indicated that Intensity (ß=0.22), borderline (ß=0.08), eating disorder (ß=0.11) symptoms, as well as Escapism (ß=0.47) and Mood Enhancement (ß=0.15) (as motivational factors) together explained 42% of DAI scores. Dance addiction as assessed with the Dance Addiction Inventory is associated with indicators of mild psychopathology and therefore warrants further research

    Correlation of X-ray diffraction signatures of breast tissue and their histopathological classification

    Get PDF
    This pilot study examines the correlation of X-ray diffraction (XRD) measurements with the histopathological analysis of breast tissue. Eight breast cancer samples were investigated. Each sample contained a mixture of normal and cancerous tissues. In total, 522 separate XRD measurements were made at different locations across the samples (8 in total). The resulting XRD spectra were subjected to principal component analysis (PCA) in order to determine if there were any distinguishing features that could be used to identify different tissue components. 99.0% of the variation between the spectra were described by the first two principal components (PC). Comparing the location of points in PC space with the classification determined by histopathology indicated correlation between the shape/magnitude of the XRD spectra and the tissue type. These results are encouraging and suggest that XRD could be used for the intraoperative or postoperative classification of bulk tissue samples

    Correlative full field X-ray Compton scattering imaging and X-ray computed tomography for in situ observation of Li ion batteries

    Get PDF
    Increasing electrode thickness is gaining more attention as a potential route to increase energy density for Li ion batteries although the realizable capacity and rate capability are usually limited by Li+ ion diffusion during (dis)charge, especially at increased (dis)charge rates. It remains challenging to visualize and quantify the low atomic number Li+ chemical stoichiometry distribution inside the electrode within commercially standard battery geometry, e.g. coin cells with stainless steel casings. Here, we map the distribution of Li + chemical stoichiometry in the electrode microstructure inside a working coin cell battery to show the amount of electrode materials contributing to energy storage performance using innovative in situ correlative full-field X-ray Compton scattering imaging (XCS-I) and X-ray computed tomography (XCT). We design and fabricate an ultra-thick (∼1 mm) cathode of LiNi0.8Mn0.1Co0.1O2 with a microstructure containing vertically oriented pore arrays using a directional ice templating method. This novel technique paves a new way to map low atomic number elements in 3D structures and study how the microstructure improves Li + ion diffusivity and energy storage performance

    3D correlative imaging of lithium ion concentration in a vertically oriented electrode microstructure with a density gradient

    Get PDF
    The performance of Li+ ion batteries (LIBs) is hindered by steep Li+ ion concentration gradients in the electrodes. Although thick electrodes (≥300 µm) have the potential for reducing the proportion of inactive components inside LIBs and increasing battery energy density, the Li+ ion concentration gradient problem is exacerbated. Most understanding of Li+ ion diffusion in the electrodes is based on computational modeling because of the low atomic number (Z) of Li. There are few experimental methods to visualize Li+ ion concentration distribution of the electrode within a battery of typical configurations, for example, coin cells with stainless steel casing. Here, for the first time, an interrupted in situ correlative imaging technique is developed, combining novel, full-field X-ray Compton scattering imaging with X-ray computed tomography that allows 3D pixel-by-pixel mapping of both Li+ stoichiometry and electrode microstructure of a LiNi0.8Mn0.1Co0.1O2 cathode to correlate the chemical and physical properties of the electrode inside a working coin cell battery. An electrode microstructure containing vertically oriented pore arrays and a density gradient is fabricated. It is shown how the designed electrode microstructure improves Li+ ion diffusivity, homogenizes Li+ ion concentration through the ultra-thick electrode (1 mm), and improves utilization of electrode active materials

    Advances in rheumatology: new targeted therapeutics

    Get PDF
    Treatment of inflammatory arthritides - including rheumatoid arthritis, ankylosing spondylitis, and psoriatic arthritis - has seen much progress in recent years, partially due to increased understanding of the pathogenesis of these diseases at the cellular and molecular levels. These conditions share some common mechanisms. Biologic therapies have provided a clear advance in the treatment of rheumatological conditions. Currently available TNF-targeting biologic agents that are licensed for at east one of the above-named diseases are etanercept, infliximab, adalimumab, golimumab, and certolizumab. Biologic agents with a different mechanism of action have also been approved in rheumatoid arthritis (rituximab, abatacept, and tocilizumab). Although these biologic agents are highly effective, there is a need for improved management strategies. There is also a need for education of family physicians and other healthcare professionals in the identification of early symptoms of inflammatory arthritides and the importance of early referral to rheumatologists for diagnosis and treatment. Also, researchers are developing molecules - for example, the Janus kinase inhibitor CP-690550 (tofacitinib) and the spleen tyrosine kinase inhibitor R788 (fostamatinib) - to target other aspects of the inflammatory cascade. Initial trial results with new agents are promising, and, in time, head-to-head trials will establish the best treatment options for patients. The key challenge is identifying how best to integrate these new, advanced therapies into daily practice
    corecore