1,346 research outputs found

    Dynamics in cardiac surgery:trends in population characteristics and the performance of the EuroSCORE II over time

    Get PDF
    OBJECTIVESThe aim of this study was to investigate the performance of the EuroSCORE II over time and dynamics in values of predictors included in the model.METHODSA cohort study was performed using data from the Netherlands Heart Registration. All cardiothoracic surgical procedures performed between 1 January 2013 and 31 December 2019 were included for analysis. Performance of the EuroSCORE II was assessed across 3-month intervals in terms of calibration and discrimination. For subgroups of major surgical procedures, performance of the EuroSCORE II was assessed across 12-month time intervals. Changes in values of individual EuroSCORE II predictors over time were assessed graphically.RESULTSA total of 103 404 cardiothoracic surgical procedures were included. Observed mortality risk ranged between 1.9% [95% confidence interval (CI) 1.6–2.4] and 3.6% (95% CI 2.6–4.4) across 3-month intervals, while the mean predicted mortality risk ranged between 3.4% (95% CI 3.3–3.6) and 4.2% (95% CI 3.9–4.6). The corresponding observed:expected ratios ranged from 0.50 (95% CI 0.46–0.61) to 0.95 (95% CI 0.74–1.16). Discriminative performance in terms of the c-statistic ranged between 0.82 (95% CI 0.78–0.89) and 0.89 (95% CI 0.87–0.93). The EuroSCORE II consistently overestimated mortality compared to observed mortality. This finding was consistent across all major cardiothoracic surgical procedures. Distributions of values of individual predictors varied broadly across predictors over time. Most notable trends were a decrease in elective surgery from 75% to 54% and a rise in patients with no or New York Heart Association I class heart failure from 27% to 33%.CONCLUSIONSThe EuroSCORE II shows good discriminative performance, but consistently overestimates mortality risks of all types of major cardiothoracic surgical procedures in the Netherlands

    Anterior ankle arthroscopy, distraction or dorsiflexion?

    Get PDF
    Anterior ankle arthroscopy can basically be performed by two different methods; the dorsiflexion- or distraction method. The objective of this study was to determine the size of the anterior working area for both the dorsiflexion and distraction method. The anterior working area is anteriorly limited by the overlying anatomy which includes the neurovascular bundle. We hypothesize that in ankle dorsiflexion the anterior neurovascular bundle will move away anteriorly from the ankle joint, whereas in ankle distraction the anterior neurovascular bundle is pulled tight towards the joint, thereby decreasing the safe anterior working area. Six fresh frozen ankle specimens, amputated above the knee, were scanned with computed tomography. Prior to scanning the anterior tibial artery was injected with contrast fluid and subsequently each ankle was scanned both in ankle dorsiflexion and in distraction. A special device was developed to reproducibly obtain ankle dorsiflexion and distraction in the computed tomography scanner. The distance between the anterior border of the inferior tibial articular facet and the posterior border of the anterior tibial artery was measured. The median distance from the anterior border of the inferior tibial articular facet to the posterior border of the anterior tibial artery in ankle dorsiflexion and distraction was 0.9 cm (range 0.7–1.5) and 0.7 cm (range 0.5–0.8), respectively. The distance in ankle dorsiflexion significantly exceeded the distance in ankle distraction (P = 0.03). The current study shows a significantly increased distance between the anterior distal tibia and the overlying anterior neurovascular bundle with the ankle in a slightly dorsiflexed position as compared to the distracted ankle position. We thereby conclude that the distracted ankle position puts the neurovascular structures more at risk for iatrogenic damage when performing anterior ankle arthroscopy

    Optimised padlock probe ligation and microarray detection of multiple (non-authorised) GMOs in a single reaction

    Get PDF
    Background To maintain EU GMO regulations, producers of new GM crop varieties need to supply an event-specific method for the new variety. As a result methods are nowadays available for EU-authorised genetically modified organisms (GMOs), but only to a limited extent for EU-non-authorised GMOs (NAGs). In the last decade the diversity of genetically modified (GM) ingredients in food and feed has increased significantly. As a result of this increase GMO laboratories currently need to apply many different methods to establish to potential presence of NAGs in raw materials and complex derived products. Results In this paper we present an innovative method for detecting (approved) GMOs as well as the potential presence of NAGs in complex DNA samples containing different crop species. An optimised protocol has been developed for padlock probe ligation in combination with microarray detection (PPLMD) that can easily be scaled up. Linear padlock probes targeted against GMO-events, -elements and -species have been developed that can hybridise to their genomic target DNA and are visualised using microarray hybridisation. In a tenplex PPLMD experiment, different genomic targets in Roundup-Ready soya, MON1445 cotton and Bt176 maize were detected down to at least 1%. In single experiments, the targets were detected down to 0.1%, i.e. comparable to standard qPCR. Conclusion Compared to currently available methods this is a significant step forward towards multiplex detection in complex raw materials and derived products. It is shown that the PPLMD approach is suitable for large-scale detection of GMOs in real-life samples and provides the possibility to detect and/or identify NAGs that would otherwise remain undetecte

    Comparison and transfer testing of multiplex ligation detection methods for GM plants

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>With the increasing number of GMOs on the global market the maintenance of European GMO regulations is becoming more complex. For the analysis of a single food or feed sample it is necessary to assess the sample for the presence of many GMO-targets simultaneously at a sensitive level. Several methods have been published regarding DNA-based multidetection. Multiplex ligation detection methods have been described that use the same basic approach: i) hybridisation and ligation of specific probes, ii) amplification of the ligated probes and iii) detection and identification of the amplified products. Despite they all have this same basis, the published ligation methods differ radically. The present study investigated with real-time PCR whether these different ligation methods have any influence on the performance of the probes. Sensitivity and the specificity of the padlock probes (PLPs) with the ligation protocol with the best performance were also tested and the selected method was initially validated in a laboratory exchange study.</p> <p>Results</p> <p>Of the ligation protocols tested in this study, the best results were obtained with the PPLMD I and PPLMD II protocols and no consistent differences between these two protocols were observed. Both protocols are based on padlock probe ligation combined with microarray detection. Twenty PLPs were tested for specificity and the best probes were subjected to further evaluation. Up to 13 targets were detected specifically and simultaneously. During the interlaboratory exchange study similar results were achieved by the two participating institutes (NIB, Slovenia, and RIKILT, the Netherlands).</p> <p>Conclusions</p> <p>From the comparison of ligation protocols it can be concluded that two protocols perform equally well on the basis of the selected set of PLPs. Using the most ideal parameters the multiplicity of one of the methods was tested and 13 targets were successfully and specifically detected. In the interlaboratory exchange study it was shown that the selected method meets the 0.1% sensitivity criterion. The present study thus shows that specific and sensitive multidetection of GMO targets is now feasible.</p

    Reduced streamflow in water-stressed climates consistent with CO2 effects on vegetation

    Get PDF
    Global environmental change has implications for the spatial and temporal distribution of water resources, but quantifying its effects remains a challenge. The impact of vegetation responses to increasing atmospheric CO2 concentrations on the hydrologic cycle is particularly poorly constrained1, 2, 3. Here we combine remotely sensed normalized difference vegetation index (NDVI) data and long-term water-balance evapotranspiration (ET) measurements from 190 unimpaired river basins across Australia during 1982–2010 to show that the precipitation threshold for water limitation of vegetation cover has significantly declined during the past three decades, whereas sub-humid and semi-arid basins are not only ‘greening’ but also consuming more water, leading to significant (24–28%) reductions in streamflow. In contrast, wet and arid basins show nonsignificant changes in NDVI and reductions in ET. These observations are consistent with expected effects of elevated CO2 on vegetation. They suggest that projected future decreases in precipitation4 are likely to be compounded by increased vegetation water use, further reducing streamflow in water-stressed regions

    Accelerated development of cerebral small vessel disease in young stroke patients.

    Get PDF
    OBJECTIVE: To study the long-term prevalence of small vessel disease after young stroke and to compare this to healthy controls. METHODS: This prospective cohort study comprises 337 patients with an ischemic stroke or TIA, aged 18-50 years, without a history of TIA or stroke. In addition, 90 age- and sex-matched controls were included. At follow-up, lacunes, microbleeds, and white matter hyperintensity (WMH) volume were assessed using MRI. To investigate the relation between risk factors and small vessel disease, logistic and linear regression were used. RESULTS: After mean follow-up of 9.9 (SD 8.1) years, 337 patients were included (227 with an ischemic stroke and 110 with a TIA). Mean age of patients was 49.8 years (SD 10.3) and 45.4% were men; for controls, mean age was 49.4 years (SD 11.9) and 45.6% were men. Compared with controls, patients more often had at least 1 lacune (24.0% vs 4.5%, p < 0.0001). In addition, they had a higher WMH volume (median 1.5 mL [interquartile range (IQR) 0.5-3.7] vs 0.4 mL [IQR 0.0-1.0], p < 0.001). Compared with controls, patients had the same volume WMHs on average 10-20 years earlier. In the patient group, age at stroke (β = 0.03, 95% confidence interval [CI] 0.02-0.04) hypertension (β = 0.22, 95% CI 0.04-0.39), and smoking (β = 0.18, 95% CI 0.01-0.34) at baseline were associated with WMH volume. CONCLUSIONS: Patients with a young stroke have a higher burden of small vessel disease than controls adjusted for confounders. Cerebral aging seems accelerated by 10-20 years in these patients, which may suggest an increased vulnerability to vascular risk factors.This is the final version of the article. It first appeared from Wolters Kluwer via https://doi.org/10.​1212/​WNL.​0000000000003123

    A reduced-reference perceptual image and video quality metric based on edge preservation

    Get PDF
    In image and video compression and transmission, it is important to rely on an objective image/video quality metric which accurately represents the subjective quality of processed images and video sequences. In some scenarios, it is also important to evaluate the quality of the received video sequence with minimal reference to the transmitted one. For instance, for quality improvement of video transmission through closed-loop optimisation, the video quality measure can be evaluated at the receiver and provided as feedback information to the system controller. The original image/video sequence-prior to compression and transmission-is not usually available at the receiver side, and it is important to rely at the receiver side on an objective video quality metric that does not need reference or needs minimal reference to the original video sequence. The observation that the human eye is very sensitive to edge and contour information of an image underpins the proposal of our reduced reference (RR) quality metric, which compares edge information between the distorted and the original image. Results highlight that the metric correlates well with subjective observations, also in comparison with commonly used full-reference metrics and with a state-of-the-art RR metric. © 2012 Martini et al
    corecore