102 research outputs found
Activity of comets: Gas Transport in the Near-Surface Porous Layers of a Cometary Nucleus
The gas transport through non-volatile random porous media is investigated
numerically. We extend our previous research of the transport of molecules
inside the uppermost layer of a cometary surface (Skorov and Rickmann, 1995;
Skorov et al. 2001). We assess the validity of the simplified capillary model
and its assumptions to simulate the gas flux trough the porous dust mantle as
it has been applied in cometary physics. A new microphysical computational
model for molecular transport in random porous media formed by packed spheres
is presented. The main transport characteristics such as the mean free path
distribution and the permeability are calculated for a wide range of model
parameters and compared with those obtained by more idealized models. The focus
in this comparison is on limitations inherent in the capillary model. Finally a
practical way is suggested to adjust the algebraic Clausing formula taking into
consideration the nonlinear dependence of permeability on layer porosity. The
retrieved dependence allows us to accurately calculate the permeability of
layers whose thickness and porosity vary in the range of values expected for
the near-surface regions of a cometary nucleus.Comment: 25 pages, 9 figure
Consistent Anisotropic Repulsions for Simple Molecules
We extract atom-atom potentials from the effective spherical potentials that
suc cessfully model Hugoniot experiments on molecular fluids, e.g., and
. In the case of the resulting potentials compare very well with the
atom-atom potentials used in studies of solid-state propertie s, while for
they are considerably softer at short distances. Ground state (T=0K) and
room temperatu re calculations performed with the new potential resolve
the previous discrepancy between experimental and theoretical results.Comment: RevTeX, 5 figure
Simulating Three-Dimensional Hydrodynamics on a Cellular-Automata Machine
We demonstrate how three-dimensional fluid flow simulations can be carried
out on the Cellular Automata Machine 8 (CAM-8), a special-purpose computer for
cellular-automata computations. The principal algorithmic innovation is the use
of a lattice-gas model with a 16-bit collision operator that is specially
adapted to the machine architecture. It is shown how the collision rules can be
optimized to obtain a low viscosity of the fluid. Predictions of the viscosity
based on a Boltzmann approximation agree well with measurements of the
viscosity made on CAM-8. Several test simulations of flows in simple geometries
-- channels, pipes, and a cubic array of spheres -- are carried out.
Measurements of average flux in these geometries compare well with theoretical
predictions.Comment: 19 pages, REVTeX and epsf macros require
Intracellular Calcium Deficits in Drosophila Cholinergic Neurons Expressing Wild Type or FAD-Mutant Presenilin
Much of our current understanding about neurodegenerative diseases can be attributed to the study of inherited forms of these disorders. For example, mutations in the presenilin 1 and 2 genes have been linked to early onset familial forms of Alzheimer's disease (FAD). Using the Drosophila central nervous system as a model we have investigated the role of presenilin in one of the earliest cellular defects associated with Alzheimer's disease, intracellular calcium deregulation. We show that expression of either wild type or FAD-mutant presenilin in Drosophila CNS neurons has no impact on resting calcium levels but does give rise to deficits in intracellular calcium stores. Furthermore, we show that a loss-of-function mutation in calmodulin, a key regulator of intracellular calcium, can suppress presenilin-induced deficits in calcium stores. Our data support a model whereby presenilin plays a role in regulating intracellular calcium stores and demonstrate that Drosophila can be used to study the link between presenilin and calcium deregulation
Lattice Boltzmann simulations of soft matter systems
This article concerns numerical simulations of the dynamics of particles
immersed in a continuum solvent. As prototypical systems, we consider colloidal
dispersions of spherical particles and solutions of uncharged polymers. After a
brief explanation of the concept of hydrodynamic interactions, we give a
general overview over the various simulation methods that have been developed
to cope with the resulting computational problems. We then focus on the
approach we have developed, which couples a system of particles to a lattice
Boltzmann model representing the solvent degrees of freedom. The standard D3Q19
lattice Boltzmann model is derived and explained in depth, followed by a
detailed discussion of complementary methods for the coupling of solvent and
solute. Colloidal dispersions are best described in terms of extended particles
with appropriate boundary conditions at the surfaces, while particles with
internal degrees of freedom are easier to simulate as an arrangement of mass
points with frictional coupling to the solvent. In both cases, particular care
has been taken to simulate thermal fluctuations in a consistent way. The
usefulness of this methodology is illustrated by studies from our own research,
where the dynamics of colloidal and polymeric systems has been investigated in
both equilibrium and nonequilibrium situations.Comment: Review article, submitted to Advances in Polymer Science. 16 figures,
76 page
Reproducibility of microvessel counts in breast cancer specimens
Assessment of tumour vascularity in core biopsy specimens may be a useful predictor of response to primary therapy. This study addresses practical methodological issues regarding accuracy of tumour vascularity assessments in different breast cancer specimens. Issues addressed in the study are variation caused by (i) inherent observer variation in the method, (ii) tumour heterogeneity and (iii) previous surgical manipulation of tumours. Microvessel counts were performed by two observers on separate occasions and by two different observers. Counts were performed on core biopsies and tumour sections taken simultaneously (n = 16) and with an intervening time interval (n = 21). In addition core biopsies were obtained from the same tumour on two separate occasions (n = 10). A highly significant correlation was found in counts performed by the same observers at different times and between two different observers. No significant correlation was found in counts of core biopsies and tumour sections taken either simultaneously or subsequently. No correlation was found between counts of sequential core biopsies. Study findings suggest that, although microvessel counts may be assessed reproducibly by the same and different observers, counts performed in core biopsies do not accurately reflect those of overall tumour, limiting their potential as predictive or prognostic markers. © 1999 Cancer Research Campaig
- …