191 research outputs found

    Making GDPR Usable: A Model to Support Usability Evaluations of Privacy

    Full text link
    We introduce a new model for evaluating privacy that builds on the criteria proposed by the EuroPriSe certification scheme by adding usability criteria. Our model is visually represented through a cube, called Usable Privacy Cube (or UP Cube), where each of its three axes of variability captures, respectively: rights of the data subjects, privacy principles, and usable privacy criteria. We slightly reorganize the criteria of EuroPriSe to fit with the UP Cube model, i.e., we show how EuroPriSe can be viewed as a combination of only rights and principles, forming the two axes at the basis of our UP Cube. In this way we also want to bring out two perspectives on privacy: that of the data subjects and, respectively, that of the controllers/processors. We define usable privacy criteria based on usability goals that we have extracted from the whole text of the General Data Protection Regulation. The criteria are designed to produce measurements of the level of usability with which the goals are reached. Precisely, we measure effectiveness, efficiency, and satisfaction, considering both the objective and the perceived usability outcomes, producing measures of accuracy and completeness, of resource utilization (e.g., time, effort, financial), and measures resulting from satisfaction scales. In the long run, the UP Cube is meant to be the model behind a new certification methodology capable of evaluating the usability of privacy, to the benefit of common users. For industries, considering also the usability of privacy would allow for greater business differentiation, beyond GDPR compliance.Comment: 41 pages, 2 figures, 1 table, and appendixe

    In vitro and in vivo studies of Cucurbita pepo L. flowers: chemical profile and bioactivity

    Get PDF
    Edible flowers consumption has increased in recent years due to their rich content of healthy phytochemicals. The aim of this study was to analyse the chemical profile of Cucurbita pepo L. flowers, and to explore their antioxidant and hypoglycaemic prop- erties. Moreover, in order to assess in vivo effects, biochemical analysis, Reactive Oxygen Metabolites (d-ROMs) and Biological Antioxidant Potential (BAP) tests were performed on mice serum. High Performance Liquid Chromatography-Diode Array Detection (HPLC-DAD) analyses revealed the presence of (þ)-catechin, ()-epicatechin, rutin, and syringic acid as main constituents. 2,20- Azino-bis (3-ethylbenzothiazoline-6-sulphonic acid) (ABTS) and Ferric Reducing Antioxidant Power (FRAP) tests showed interest- ing results. The extract exhibited the strongest inhibitory effect on a-glucosidase (IC50 of 144.77lg/mL). In vivo results confirmed the hypoglycaemic effects, also affecting lipid metabolism but did not revealed benefits on ROS production. These results may add some information supporting the use of C. pepo flowers as func- tional foods and/or nutraceuticals

    Highlights from CHIMERA Collaboration

    Get PDF
    The activities performed by the CHIMERA Collaboration since the 2018 IWM-EC workshop are outlined in this paper. Experiments performed in thelast three years and results obtained through dedicated analyses of experimentaldata already acquired are summarized. A brief report on the activities conductedat GSI is also include

    Status of data analysis and preliminary results of the CHIFAR experiment

    Get PDF
    In the CHIFAR experiment, carried out at the INFN-LNS laboratory, we studied reactions between beams of Sn-124, Xe-124 and Sn-112, accelerated at 20 AMeV, and targets of Ni-64, Zn-64 and Ni-58 by using the CHIMERA multi-detector coupled to 10 telescopes of the FARCOS array. The main topics of the experiment are the competition between reaction mechanisms and the Intermediate Mass Fragment production phenomenon, aiming to extend towards the low energy regime the studies performed in previous CHIMERA experiments carried out at beam energy of 35 AMeV. Status of data analysis arid preliminary results will be presented

    Baseline mitral regurgitation predicts outcome in patients referred for dobutamine stress echocardiography

    Get PDF
    Purpose: A number of parameters recorded during dobutamine stress echocardiography (DSE) are associated with worse outcome. However, the relative importance of baseline mitral regurgitation (MR) is unknown. The aim of this study was to assess the prevalence and associated implications of functional MR with long-term mortality in a large cohort of patients referred for DSE. Methods: 6745 patients (mean age 64.9±12.2 years) were studied. Demographic, baseline and peak DSE data were collected. All-cause mortality was retrospectively analyzed. DSE was successfully completed in all patients with no adverse outcomes. Results: MR was present in 1019 (15.1%) patients. During a mean follow up of 5.1±1.8 years, 1642 (24.3%) patients died and MR was significantly associated with increased all-cause mortality (p<0.001). With Kaplan-Meier analysis, survival was significantly worse for patients with moderate and severe MR (p<0.001). With multivariate Cox regression analysis, moderate and severe MR (HR 2.78; 95% CI 2.17 - 3.57; and HR 3.62; 95% CI 2.89 - 4.53, respectively) were independently associated with all-cause mortality. The addition of MR to C statistic models significantly improved discrimination. Conclusions: MR is associated with all-cause mortality and adds incremental prognostic information among patients referred for DSE. The presence of MR should be taken into account when evaluating the prognostic significance of DSE results

    Aspecto socio-cultural de la transferencia de tecnología de energías renovables en la comunidad terapéutica de Tekové-Rogá

    Get PDF
    La experiencia realizada en la Comunidad Terapéutica de Tekové-Rogá se encuadra en el Proyecto de Ejecución Práctica y Educación en Energías Renovables y Agua Potable, su implementación depende del Ministerio de Desarrollo Social de la Nación, la Secretaría Nacional de Niñez, Adolescencia y Familia (SENNAF) y la Universidad Tecnológica Nacional (UTN). El objetivo del trabajo es analizar el impacto social que este tipo de experiencias genera, para lograrlo el abordaje metodológico utilizado fue cuanti-cualitativo, en tanto se recolectaron datos estadísticos de la institución que permitieron relevar información sobre su plantel profesional, y cualitativa en tanto indagamos las percepciones que los actores de la institución tienen en relación al proyecto de ejecución en energías renovables. Las conclusiones principales dan cuenta del impacto social en tres ejes diferentes: el impacto a nivel institucional de la comunidad terapéutica, el impacto a nivel socio-cultural y el impacto a nivel académico.The experience realized in Tekové-Rogá's Therapeutic Community is fitted in the Project of Practical Execution and Education in Renewable Energies and Water, his implementation depends on the Department of Social Development of the Nation, the National Secretariat of Childhood, Adolescence and Family (SENNAF) and the Technological National University (UTN). The work analyze the social impact that this type of experiences. The principal conclusions are in three different axes: the first one is related to the impact to institutional level of the therapeutic community, the second one links itself with the impact to socio-cultural level, which can be indirect ó directly. Finally the third axis in which the social impact is identified is to academic level, in which they receive relevancy the innovation in the development of new devices, the role of the university and the impact in the professional identities involved in the project.Asociación Argentina de Energías Renovables y Medio Ambiente (ASADES

    Abnormal shortened diastolic time length at increasing heart rates in patients with abnormal exercise-induced increase in pulmonary artery pressure

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The degree of pulmonary hypertension is not independently related to the severity of left ventricular systolic dysfunction but is frequently associated with diastolic filling abnormalities. The aim of this study was to assess diastolic times at increasing heart rates in normal and in patients with and without abnormal exercise-induced increase in pulmonary artery pressure (PASP). Methods. We enrolled 109 patients (78 males, age 62 ± 13 years) referred for exercise stress echocardiography and 16 controls. The PASP was derived from the tricuspid Doppler tracing. A cut-off value of PASP ≥ 50 mmHg at peak stress was considered as indicative of abnormal increase in PASP. Diastolic times and the diastolic/systolic time ratio were recorded by a precordial cutaneous force sensor based on a linear accelerometer.</p> <p>Results</p> <p>At baseline, PASP was 30 ± 5 mmHg in patients and 25 ± 4 in controls. At peak stress the PASP was normal in 95 patients (Group 1); 14 patients (Group 2) showed an abnormal increase in PASP (from 35 ± 4 to 62 ± 12 mmHg; P < 0.01). At 100 bpm, an abnormal (< 1) diastolic/systolic time ratio was found in 0/16 (0%) controls, in 12/93 (13%) Group 1 and 7/14 (50%) Group 2 patients (p < 0.05 between groups).</p> <p>Conclusion</p> <p>The first and second heart sound vibrations non-invasively monitored by a force sensor are useful for continuously assessing diastolic time during exercise. Exercise-induced abnormal PASP was associated with reduced diastolic time at heart rates beyond 100 beats per minute.</p

    Post-exercise contractility, diastolic function, and pressure: Operator-independent sensor-based intelligent monitoring for heart failure telemedicine

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>New sensors for intelligent remote monitoring of the heart should be developed. Recently, a cutaneous force-frequency relation recording system has been validated based on heart sound amplitude and timing variations at increasing heart rates.</p> <p>Aim</p> <p>To assess sensor-based post-exercise contractility, diastolic function and pressure in normal and diseased hearts as a model of a wireless telemedicine system.</p> <p>Methods</p> <p>We enrolled 150 patients and 22 controls referred for exercise-stress echocardiography, age 55 ± 18 years. The sensor was attached in the precordial region by an ECG electrode. Stress and recovery contractility were derived by first heart sound amplitude vibration changes; diastolic times were acquired continuously. Systemic pressure changes were quantitatively documented by second heart sound recording.</p> <p>Results</p> <p>Interpretable sensor recordings were obtained in all patients (feasibility = 100%). Post-exercise contractility overshoot (defined as increase > 10% of recovery contractility vs exercise value) was more frequent in patients than controls (27% vs 8%, p < 0.05). At 100 bpm stress heart rate, systolic/diastolic time ratio (normal, < 1) was > 1 in 20 patients and in none of the controls (p < 0.01); at recovery systolic/diastolic ratio was > 1 in only 3 patients (p < 0.01 vs stress). Post-exercise reduced arterial pressure was sensed.</p> <p>Conclusion</p> <p>Post-exercise contractility, diastolic time and pressure changes can be continuously measured by a cutaneous sensor. Heart disease affects not only exercise systolic performance, but also post-exercise recovery, diastolic time intervals and blood pressure changes – in our study, all of these were monitored by a non-invasive wearable sensor.</p

    Arterial pressure changes monitoring with a new precordial noninvasive sensor

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recently, a cutaneous force-frequency relation recording system based on first heart sound amplitude vibrations has been validated. A further application is the assessment of Second Heart Sound (S2) amplitude variations at increasing heart rates. The aim of this study was to assess the relationship between second heart sound amplitude variations at increasing heart rates and hemodynamic changes.</p> <p>Methods</p> <p>The transcutaneous force sensor was positioned in the precordial region in 146 consecutive patients referred for exercise (n = 99), dipyridamole (n = 41), or pacing stress (n = 6). The curve of S2 peak amplitude variation as a function of heart rate was computed as the increment with respect to the resting value.</p> <p>Results</p> <p>A consistent S2 signal was obtained in all patients. Baseline S2 was 7.2 ± 3.3 m<it>g</it>, increasing to 12.7 ± 7.7 m<it>g </it>at peak stress. S2 percentage increase was + 133 ± 104% in the 99 exercise, + 2 ± 22% in the 41 dipyridamole, and + 31 ± 27% in the 6 pacing patients (p < 0.05). Significant determinants of S2 amplitude were blood pressure, heart rate, and cardiac index with best correlation (R = .57) for mean pressure.</p> <p>Conclusion</p> <p>S2 recording quantitatively documents systemic pressure changes.</p

    Coronary flow reserve in stress-echo lab. From pathophysiologic toy to diagnostic tool

    Get PDF
    The assessment of coronary flow reserve by transthoracic echocardiography has recently been introduced into clinical practice with gratifying results for the diagnosis of left anterior descending artery disease simultaneously reported by several independent laboratories. This technological novelty is changing the practice of stress echo for 3 main reasons. First, adding coronary flow reserve to regional wall motion allows us to have – in the same sitting – high specificity (regional wall motion) and a high sensitivity (coronary flow reserve) diagnostic marker, with an obvious improvement in overall diagnostic accuracy. Second, the technicalities of coronary flow reserve shift the balance of stress choice in favour of vasodilators, which are a more robust hyperemic stress and are substantially easier to perform with dual imaging than dobutamine or exercise. Third, the coronary flow reserve adds a quantitative support to the exquisitely qualitative assessment of wall motion analysis, thereby facilitating the communication of stress echo results to the cardiological world outside the echo lab. The next challenges involve the need to expand the exploration of coronary flow reserve to the right and circumflex coronary artery and to prove the additional prognostic value – if any – of coronary flow reserve over regional wall motion analysis, which remains the cornerstone of clinically-driven diagnosis in the stress echo lab
    corecore