19 research outputs found

    Failed surgical ligation of the proximal left subclavian artery during hybrid thoracic endovascular aortic repair successfully managed by percutaneous plug or coil occlusion: a report of 3 cases

    Get PDF
    Open surgical rerouting and proximal ligation of one or more supra-aortic vessels prior to endovascular stent-graft placement has become an alternative to major open thoracic surgery in the treatment of complex thoracic aortic disease. Complications owing to failed surgical ligation of the left subclavian artery are rare. In this report, 3 cases of failed ligation are presented. Diagnosis was made by CT-scan and treatment was performed by transcatheter coil and plug embolization, avoiding redo neck surgery

    Serological evidence for transmission of multiple dengue virus serotypes in Papua New Guinea and West Papua prior to 1963

    Get PDF
    Little is known about the natural history of dengue in Papua New Guinea (PNG). We assessed dengue virus (DENV)-specific neutralizing antibody profiles in serum samples collected from northern and southern coastal areas and the highland region of New Guinea between 1959 and 1963. Neutralizing antibodies were demonstrated in sera from the northern coast of New Guinea: from Sabron in Dutch New Guinea (now known as West Papua) and from four villages in East Sepik in what is now PNG. Previous monotypic infection with DENV-1, DENV-2, and DENV-4 was identified, with a predominance of anti-DENV-2 neutralizing antibody. The majority of positive sera demonstrated evidence of multiple previous DENV infections and neutralizing activity against all four serotypes was detected, with anti-DENV-2 responses being most frequent and of greatest magnitude. No evidence of previous DENV infection was identified in the Asmat villages of the southern coast and a single anti-DENV-positive sample was identified in the Eastern Highlands of PNG. These findings indicate that multiple DENV serotypes circulated along the northern coast of New Guinea at different times in the decades prior to 1963 and support the notion that dengue has been a significant yet neglected tropical infection in PNG for many decades

    Results of endovascular repair of the thoracic aorta with the Talent Thoracic stent graft: the Talent Thoracic Retrospective Registry.

    No full text
    Background: Endovascular treatment of thoracic aortic diseases demonstrated low perioperative morbidity and mortality when compared with conventional open repair. Long-term effectiveness of this minimally invasive technique remains to be proven. The Talent Thoracic Retrospective Registry was designed to evaluate the impact of this therapy on patients treated in 7 major European referral centers over an 8-year period. Methods: Data from 457 consecutive patients (113 emergency and 344 elective cases) who underwent endovascular thoracic aortic repair with the Medtronic Talent Thoracic stent graft (Medtronic/AVE, Santa Rosa, Calif) were collected. Follow-up analysis (24 \ub1 19.4 months, range 1-85.1 months) was based on clinical and imaging findings, including all adverse events. To ensure consistency of data interpretation and event reporting, one physician reviewed all adverse events and deaths for the whole cohort of patients. In the case of discrepancies, the treating physicians were queried. Findings: Among 422 patients who survived the interventional procedure (in-hospital mortality 5%, 23 patients), mortality during follow-up was 8.5% (36 patients), and in 11 of them the death was related to the aortic disease. Persistent endoleak was reported at imaging follow-up in 64 cases: 44 were primary (9.6%) and 21 occurred during follow-up (4.9%). Seven patients with persistent endoleak had aortic rupture during follow-up, at a variable time from 40 days to 35 months, and all subsequently died. A minor incidence of migration of the stent graft (7 cases), graft fabric alteration (2 cases), and modular disconnection (3 cases) was observed at imaging. Kaplan-Meier overall survival estimate at 1 year was 90.97%, at 3 years was 85.36%, and at 5 years was 77.49%. At the same intervals, freedom from a second procedure (either open conversion or endovascular) was 92.45%, 81.3%, and 70.0%, respectively. Conclusion: Endovascular treatment for thoracic aortic disease with the Talent stent graft is associated with low early morbidity and mortality rates also for patients who are at high risk and treated on an emergency basis. Follow-up data indicate a substantial durability of the procedure with a high freedom from related death and secondary interventions

    Establishment of diagnostic reference levels in cardiac ct in france A need for patient dose optimisation

    No full text
    International audienceThe objective of this study was to propose diagnostic reference levels (DRLs) for coronary computed tomography angiography (CCTA), in the context of a large variability in patient radiation dose, and the lack of European recommendations. Volume Computed Tomography Dose Index (CTDIvol) and dose-length product (DLP) were collected from 460 CCTAs performed over a 3-month period at eight French hospitals. CCTAs (50 per centre) were performed using the routine protocols of the centres, and 64- to 320-detector CT scanners. ECG gating was prospective (n = 199) or retrospective (n = 261). The large gap in dose between these two modes required to propose specific DRLs 26 and 44 mGy for CTDIvol, and 370 and 970 mGy cm for DLP, respectively. This study confirms the large variability in patient doses during CCTA and underlines the need for the optimisation of cardiac acquisition protocols. Availability of national DRLs should be mandatory in this setting. © The Author 2014
    corecore