256 research outputs found

    Swab test in biological fluids as predictor of COVID-19 transmission risk during surgery: a prospective cross-sectional study from an Italian COVID center

    Get PDF
    Background The contamination of body fluids by Severe Acute Respiratory Syndrome Coronavirus 2 during surgery is current matter of debate in the scientific literature concerning CoronaVIrus Disease 2019. Surgical guidelines were published during the first wave of the COVID-19 pandemic and recommended to avoid laparoscopic surgery as much as possible, in fear that the chimney effect of high flow intraperitoneal gas escape during, and after, the procedure would increase the risk of viral transmission. Aim The aim of this study was to evaluate the possibility of SARS-CoV-2 transmission during surgery by searching for viral RNA in serial samplings of biological liquids. Methods This is a single center prospective cross-sectional study. We used a real-time reverse transcriptase (RT) polymerase chain reaction (PCR) test to perform swab tests for the qualitative detection of nucleic acid from SARS-CoV-2 in abdominal fluids, during emergency surgery and on the first post-operative day. In the case of thoracic surgery, we performed a swab test of pleural fluids during chest drainage placement as well as on the first post-operative day. Results A total of 20 samples were obtained: 5 from pleural fluids, 13 from peritoneal fluids and two from biliary fluid. All 20 swabs performed from biological fluids resulted negative for SARS-CoV-2 RNA detection. Conclusion To date, there is no scientific evidence of possible contagion by laparoscopic aerosolization of SARS-CoV-2, neither is certain whether the virus is effectively present in biological fluids

    Percutaneous transfemoral-transseptal implantation of a second-generation CardiAQ™ mitral valve bioprosthesis: first procedure description and 30-day follow-up

    Get PDF
    Transcatheter mitral valve implantation for mitral valve regurgitation is in the very early phase of development because of challenging anatomy and device dimensions. We describe the procedure of a transfemoral-transseptal implantation of the second-generation CardiAQ™ mitral valve bioprosthesis and 30-day follow-up

    Alcohol Septal Ablation for Hypertrophic Obstructive Cardiomyopathy: A Contemporary Reappraisal

    Get PDF
    Percutaneous alcohol septal ablation (ASA) is an effective and minimally invasive therapeutic strategy to resolve left ventricular outflow tract obstruction (LVOTO) in patients with hypertrophic cardiomyopathy who remain symptomatic on maximally tolerated medical therapy. First performed by Sigwart in 1994, the procedure consists in determining an iatrogenic infarction of the basal interventricular septum to reduce LVOTO and alleviate symptoms. Since its first description, numerous studies have demonstrated its efficacy and safety, proposing ASA as a valid and attractive alternative to surgical septal myectomy. The success rate of the intervention is profoundly affected by patient selection and centre experience. In this review, we sought to summarise current evidence on ASA, describing the procedure and proposing a cardiomyopathy team-based approach to resolve clinical disputes in clinical practice

    Long Stent Implantation on the Left Anterior Descending Coronary Artery at a Follow-Up of More Than Five Years

    Get PDF
    Background: Stent implantation represents the standard of care in coronary intervention. While a short stent implanted on a focal lesion located on the left anterior descending artery (LAD) seems a reasonable alternative to an internal mammary implant, the same for long stents is still debated. Methods: We reported the long-term data of 531 consecutive patients who underwent Percutaneous Coronary Intervention (PCI) with long stents in two highly specialized centres. The main inclusion criteria were the implantation of stents longer than 30 mm on the LAD and a minimum follow-up (FU) of five years. The primary endpoint was mortality, and the secondary endpoints were any myocardial infarction (MI), target vessel and lesion revascularization (TVR and TLR, respectively), and stent thrombosis (ST) observed as definite, probable, or possible. Results: In this selected population with characteristics of complex PCI (99.1%), the long-term follow-up (mean 92.18 ± 35.5 months) estimates of all-cause death, cardiovascular death, and any myocardial infarction were 18.3%, 10.5%, and 9.3%, respectively. Both all-cause and cardiovascular deaths are significantly associated with three-vessel disease (HR 6.8; confidence of interval (CI) 95% 3.844–11.934; p &lt; 0.001, and HR 4.7; CI 95% 2.265–9.835; p &lt; 0.001, respectively). Target lesion (TLR) and target vessel revascularization (TVR) are associated with the presence of three-lesion disease on the LAD (HR 3.4; CI 95% 1.984–5.781; p &lt; 0.001; HR 3.9 CI 95% 2.323–6.442; p &lt; 0.001, respectively). Re-PCI for any cause occurred in 31.5% of patients and shows an increased risk for three-lesion stenting (HR 4.3; CI 95% 2.873–6.376; p &lt; 0.001) and the treatment of bifurcation with two stents (HR 1.6; 95% CI 1.051–2.414; p = 0.028). Stent thrombosis rate at the 5-year FU was 4.4% (1.3% definite; 0.9% probable; 2.1% possible), including a 1.7% rate of very-late thrombosis. The stent length superior to 40 mm was not associated with poor outcomes (all-cause death p = 0.349; cardiovascular death p = 0.855; MI p = 0.691; re-PCI p = 0.234; TLR p = 0.805; TVR p = 0.087; ST p = 0.189). Conclusion: At an FU of longer than five years, patients treated with stents longer than 30 mm in their LAD showed acceptable procedural results but poor outcomes.</p

    Long Stent Implantation on the Left Anterior Descending Coronary Artery at a Follow-Up of More Than Five Years

    Get PDF
    Background: Stent implantation represents the standard of care in coronary intervention. While a short stent implanted on a focal lesion located on the left anterior descending artery (LAD) seems a reasonable alternative to an internal mammary implant, the same for long stents is still debated. Methods: We reported the long-term data of 531 consecutive patients who underwent Percutaneous Coronary Intervention (PCI) with long stents in two highly specialized centres. The main inclusion criteria were the implantation of stents longer than 30 mm on the LAD and a minimum follow-up (FU) of five years. The primary endpoint was mortality, and the secondary endpoints were any myocardial infarction (MI), target vessel and lesion revascularization (TVR and TLR, respectively), and stent thrombosis (ST) observed as definite, probable, or possible. Results: In this selected population with characteristics of complex PCI (99.1%), the long-term follow-up (mean 92.18 ± 35.5 months) estimates of all-cause death, cardiovascular death, and any myocardial infarction were 18.3%, 10.5%, and 9.3%, respectively. Both all-cause and cardiovascular deaths are significantly associated with three-vessel disease (HR 6.8; confidence of interval (CI) 95% 3.844–11.934; p &lt; 0.001, and HR 4.7; CI 95% 2.265–9.835; p &lt; 0.001, respectively). Target lesion (TLR) and target vessel revascularization (TVR) are associated with the presence of three-lesion disease on the LAD (HR 3.4; CI 95% 1.984–5.781; p &lt; 0.001; HR 3.9 CI 95% 2.323–6.442; p &lt; 0.001, respectively). Re-PCI for any cause occurred in 31.5% of patients and shows an increased risk for three-lesion stenting (HR 4.3; CI 95% 2.873–6.376; p &lt; 0.001) and the treatment of bifurcation with two stents (HR 1.6; 95% CI 1.051–2.414; p = 0.028). Stent thrombosis rate at the 5-year FU was 4.4% (1.3% definite; 0.9% probable; 2.1% possible), including a 1.7% rate of very-late thrombosis. The stent length superior to 40 mm was not associated with poor outcomes (all-cause death p = 0.349; cardiovascular death p = 0.855; MI p = 0.691; re-PCI p = 0.234; TLR p = 0.805; TVR p = 0.087; ST p = 0.189). Conclusion: At an FU of longer than five years, patients treated with stents longer than 30 mm in their LAD showed acceptable procedural results but poor outcomes.</p

    Inadequacy of Existing Clinical Prediction Models for Predicting Mortality after Transcatheter Aortic Valve Implantation

    Get PDF
    Background: The performance of emerging transcatheter aortic valve implantation (TAVI) clinical prediction models (CPMs) in national TAVI cohorts distinct from those where they have been derived is unknown. This study aimed to investigate the performance of the German Aortic Valve, FRANCE-2, OBSERVANT and American College of Cardiology (ACC) TAVI CPMs compared with the performance of historic cardiac CPMs such as the EuroSCORE and STS-PROM, in a large national TAVI registry. Methods: The calibration and discrimination of each CPM were analyzed in 6676 patients from the UK TAVI registry, as a whole cohort and across several subgroups. Strata included gender, diabetes status, access route, and valve type. Furthermore, the amount of agreement in risk classification between each of the considered CPMs was analyzed at an individual patient level. Results: The observed 30-day mortality rate was 5.4%. In the whole cohort, the majority of CPMs over-estimated the risk of 30-day mortality, although the mean ACC score (5.2%) approximately matched the observed mortality rate. The areas under ROC curve were between 0.57 for OBSERVANT and 0.64 for ACC. Risk classification agreement was low across all models, with Fleiss's kappa values between 0.17 and 0.50. Conclusions: Although the FRANCE-2 and ACC models outperformed all other CPMs, the performance of current TAVI-CPMs was low when applied to an independent cohort of TAVI patients. Hence, TAVI specific CPMs need to be derived outside populations previously used for model derivation, either by adapting existing CPMs or developing new risk scores in large national registries

    Cardiovascular magnetic resonance for the assessment of patients undergoing transcatheter aortic valve implantation: a pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Before trans-catheter aortic valve implantation (TAVI), assessment of cardiac function and accurate measurement of the aortic root are key to determine the correct size and type of the prosthesis. The aim of this study was to compare cardiovascular magnetic resonance (CMR) and trans-thoracic echocardiography (TTE) for the assessment of aortic valve measurements and left ventricular function in high-risk elderly patients submitted to TAVI.</p> <p>Methods</p> <p>Consecutive patients with severe aortic stenosis and contraindications for surgical aortic valve replacement were screened from April 2009 to January 2011 and imaged with TTE and CMR.</p> <p>Results</p> <p>Patients who underwent both TTE and CMR (n = 49) had a mean age of 80.8 ± 4.8 years and a mean logistic EuroSCORE of 14.9 ± 9.3%. There was a good correlation between TTE and CMR in terms of annulus size (R<sup>2 </sup>= 0.48, p < 0.001), left ventricular outflow tract (LVOT) diameter (R<sup>2 </sup>= 0.62, p < 0.001) and left ventricular ejection fraction (LVEF) (R<sup>2 </sup>= 0.47, p < 0.001) and a moderate correlation in terms of aortic valve area (AVA) (R<sup>2 </sup>= 0.24, p < 0.001). CMR generally tended to report larger values than TTE for all measurements. The Bland-Altman test indicated that the 95% limits of agreement between TTE and CMR ranged from -5.6 mm to + 1.0 mm for annulus size, from -0.45 mm to + 0.25 mm for LVOT, from -0.45 mm<sup>2 </sup>to + 0.25 mm<sup>2 </sup>for AVA and from -29.2% to 13.2% for LVEF.</p> <p>Conclusions</p> <p>In elderly patients candidates to TAVI, CMR represents a viable complement to transthoracic echocardiography.</p
    corecore