71 research outputs found

    Core Outcome Set for GROwth restriction: deVeloping Endpoints (COSGROVE).

    Get PDF
    BACKGROUND: Foetal growth restriction (FGR) refers to a foetus that does not reach its genetically predetermined growth potential. It is well recognised that growth-restricted foetuses are at increased risk of stillbirth, foetal compromise, early neonatal death and neonatal morbidity. Later in life, they are prone to health problems, including increased risk of cardiovascular diseases and neurodevelopmental disorders. Interventions for preventing and treating FGR have been studied in many trials, but evidence is often difficult to synthesise and compare because of differences in the selection and definition of outcomes. To enable future trials to measure similar, meaningful outcomes, we are developing two core outcome sets (COS) - one for prevention and the other for treatment of FGR. METHODS: We will review the literature to identify previously reported outcomes. An international panel of relevant stakeholders who have experience of FGR (parent or carer of a baby that was growth restricted, health professional involved in the care of mothers and babies affected by FGR, a person with expertise in FGR research) will rate the importance of each of those outcomes in a series of three sequential online rounds of a Delphi study. Participants will be able to add items to the proposed list in round 1. A final face-to-face consensus meeting will be held with representatives of each stakeholder group at which a final list of outcomes for inclusion in the COS will be agreed. DISCUSSION: The development of COSs in FGR will ensure the collection and reporting of a minimum dataset agreed by stakeholder consensus and will reduce inconsistencies in the reporting of outcomes across relevant trials. Such standardisation in the reporting of outcomes will improve synthesis of evidence and generalisability of knowledge in the future by reducing heterogeneity in outcomes between trials and thus improve the results of systematic reviews and meta-analyses. Ultimately, we hope that the COSs will lead to an improvement in the quality of evidence-based clinical practice, enhance patient care, and improve the quality and consistency of research. TRIAL REGISTRATION: Not applicable. This study is registered in the Core Outcome Measures for Effectiveness (COMET) database

    A Core Outcome Set for the prevention and treatment of fetal GROwth restriction: deVeloping Endpoints: the COSGROVE study.

    Get PDF
    BACKGROUND: Fetal growth restriction refers to a fetus that does not reach its genetically predetermined growth potential. It is well-recognized that growth-restricted fetuses are at increased risk of both short- and long-term adverse outcomes. Systematic evaluation of the evidence from clinical trials of fetal growth restriction is often difficult because of variation in the outcomes that are measured and reported. The development of core outcome sets for fetal growth restriction studies would enable future trials to measure similar meaningful outcomes. OBJECTIVE: The purpose of this study was to develop core outcome sets for trials of prevention or treatment of fetal growth restriction. STUDY DESIGN: This was a Delphi consensus study. A comprehensive literature review was conducted to identify outcomes that were reported in studies of prevention or treatment of fetal growth restriction. All outcomes were presented for prioritization to key stakeholders (135 healthcare providers, 68 researchers/academics, and 35 members of the public) in 3 rounds of online Delphi surveys. A priori consensus criteria were used to reach agreement on the final outcomes for inclusion in the core outcome set at a face-to-face meeting with 5 healthcare providers, 5 researchers/academics, and 6 maternity service users. RESULTS: In total, 22 outcomes were included in the final core outcome set. These outcomes were grouped under 4 domains: maternal (n=4), fetal (n=1), neonatal (n=12), and childhood (n=5). CONCLUSION: The Core Outcome Set for the prevention and treatment of fetal GROwth restriction: deVeloping Endpoints study identified a large number of potentially relevant outcomes and then reached consensus on those factors that, as a minimum, should be measured and reported in all future trials of prevention or treatment of fetal growth restriction. This will enable future trials to measure similar meaningful outcomes and to ensure that findings from different studies can be compared and combined

    Predictors of Poor Perinatal Outcome following Maternal Perception of Reduced Fetal Movements: A Prospective Cohort Study

    Get PDF
    Background Maternal perception of reduced fetal movement (RFM) is associated with increased risk of stillbirth and fetal growth restriction (FGR). RFM is thought to represent fetal compensation to conserve energy due to insufficient oxygen and nutrient transfer resulting from placental insufficiency. Objective To identify predictors of poor perinatal outcome after maternal perception of reduced fetal movements (RFM). Design Prospective cohort study. Methods 305 women presenting with RFM after 28 weeks of gestation were recruited. Demographic factors and clinical history were recorded and ultrasound performed to assess fetal biometry, liquor volume and umbilical artery Doppler. A maternal serum sample was obtained for measurement of placentally-derived or modified proteins including: alpha fetoprotein (AFP), human chorionic gonadotrophin (hCG), human placental lactogen (hPL), ischaemia-modified albumin (IMA), pregnancy associated plasma protein A (PAPP-A) and progesterone. Factors related to poor perinatal outcome were determined by logistic regression. Results 22.1% of pregnancies ended in a poor perinatal outcome after RFM. The most common complication was small-for-gestational age infants. Pregnancy outcome after maternal perception of RFM was related to amount of fetal activity while being monitored, abnormal fetal heart rate trace, diastolic blood pressure, estimated fetal weight, liquor volume, serum hCG and hPL. Following multiple logistic regression abnormal fetal heart rate trace (Odds ratio 7.08, 95% Confidence Interval 1.31–38.18), (OR) diastolic blood pressure (OR 1.04 (95% CI 1.01–1.09), estimated fetal weight centile (OR 0.95, 95% CI 0.94–0.97) and log maternal serum hPL (OR 0.13, 95% CI 0.02–0.99) were independently related to pregnancy outcome. hPL was related to placental mass. Conclusion Poor perinatal outcome after maternal perception of RFM is closely related to factors which are connected to placental dysfunction. Novel tests of placental function and associated fetal response may provide improved means to detect fetuses at greatest risk of poor perinatal outcome after RFM

    Maternal Perception of Reduced Fetal Movements Is Associated with Altered Placental Structure and Function

    Get PDF
    Maternal perception of reduced fetal movement (RFM) is associated with increased risk of stillbirth and fetal growth restriction (FGR). DFM is thought to represent fetal compensation to conserve energy due to insufficient oxygen and nutrient transfer resulting from placental insufficiency. To date there have been no studies of placental structure in cases of DFM.To determine whether maternal perception of reduced fetal movements (RFM) is associated with abnormalities in placental structure and function.Placentas were collected from women with RFM after 28 weeks gestation if delivery occurred within 1 week. Women with normal movements served as a control group. Placentas were weighed and photographs taken. Microscopic structure was evaluated by immunohistochemical staining and image analysis. System A amino acid transporter activity was measured as a marker of placental function. Placentas from all pregnancies with RFM (irrespective of outcome) had greater area with signs of infarction (3.5% vs. 0.6%; p<0.01), a higher density of syncytial knots (p<0.001) and greater proliferation index (p<0.01). Villous vascularity (p<0.001), trophoblast area (p<0.01) and system A activity (p<0.01) were decreased in placentas from RFM compared to controls irrespective of outcome of pregnancy.This study provides evidence of abnormal placental morphology and function in women with RFM and supports the proposition of a causal association between placental insufficiency and RFM. This suggests that women presenting with RFM require further investigation to identify those with placental insufficiency

    Multidisciplinary consensus on screening for, diagnosis and management of fetal growth restriction in the Netherlands

    Get PDF
    Screening for, diagnosis and management of intrauterine growth restriction (IUGR) is often performed in multidisciplinary collaboration. However, variation in screening methods, diagnosis and management of IUGR may lead to confusion. In the Netherlands two monodisciplinary guidelines on IUGR do not fully align. To facilitate effective collaboration between different professionals in perinatal care, we undertook a Delphi study with uniform recommendations as our primary result, focusing on issues that are not aligned or for which specifications are lacking in the current guidelines. We conducted a Delphi study in three rounds. A purposively sampled selection of 56 panellists participated: 27 representing midwife-led care and 29 obstetrician-led care. Consensus was defined as agreement between the professional groups on the same answer and among at least 70% of the panellists within groups. Per round 51 or 52 (91% - 93%) panellists responded. This has led to consensus on 27 issues, leading to four consensus based recommendations on screening for IUGR in midwife-led care and eight consensus based recommendations on diagnosis and eight on management in obstetrician-led care. The multidisciplinary project group decided on four additional recommendations as no consensus was reached by the panel. No recommendations could be made about induction of labour versus expectant monitoring, nor about the choice for a primary caesarean section. We reached consensus on recommendations for care for IUGR within a multidisciplinary panel. These will be implemented in a study on the effectiveness and cost-effectiveness of routine third trimester ultrasound for monitoring fetal growth. Research is needed to evaluate the effects of implementation of these recommendations on perinatal outcomes. NTR436
    • 

    corecore