59 research outputs found

    Differential cross section measurement for the d(n,np) reaction

    Get PDF
    Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2010.This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.Cataloged from student-submitted PDF version of thesis.Includes bibliographical references (p. 83-84).The differential cross section for the quasielastic d(n,np) neutron-induced deuteron breakup reaction was measured as a function of incident and scattered particle energies and angles, using a liquid deuterium target at the Weapons Neutron Research (WNR) spallation neutron beam at the Los Alamos Neutron Science Center at the Los Alamos National Laboratory. Cross sections were computed for the incident neutron energy ranges of 10010, 20010, and 30010 MeV. We used proton detectors covering a range of = 17 - 25 in the lab frame, and neutron detectors covering a range of = 55 - 76 in the lab frame. Experiment setup and data analysis are discussed, and preliminary results are presented for the cross section.by Sho Uemura.S.B

    Unraveling Fano noise and partial charge collection effect in X-ray spectra below 1 keV

    Full text link
    Fano noise, readout noise, and the partial charge collection (PCC) effect collectively contribute to the degradation of energy spectra in Charge Coupled Devices (CCD) measurements, especially at low energies. In this work, the X-ray produced by the fluorescence of fluorine (677 eV) and aluminum (1486 eV) were recorded using a Skipper-CCD, which enabled the reading noise to be reduced to 0.2 e-. Based on an analytical description of photopeak shapes resulting from the convolution of the PCC effect and Fano noise, we achieved a precise characterization of the energy spectra. This description enabled us to disentangle and quantify the contributions from both Fano noise and the PCC effect. As a result, we determined the Fano factor and the electron-hole pair creation energy. Additionally, we estimated the PCC-region of the sensor and, for the first time, experimentally observed the expected skewness of photopeaks at low energies.Comment: 8 pages, 5 figure

    Smart Readout of Nondestructive Image Sensors with Single Photon-Electron Sensitivity

    Get PDF
    Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible light and other applications that require faster readout times. The method optimizes the readout noise and time by changing the number of times pixels are read out either statically, by defining an arbitrary number of regions of interest in the array, or dynamically, depending on the charge or energy of interest in the pixel. This technique is tested in a Skipper CCD showing that it is possible to obtain deep subelectron noise, and therefore, high resolution of quantized charge, while dynamically changing the readout noise of the sensor. These faster, low noise readout techniques show that the skipper CCD is a competitive technology even where other technologies such as electron multiplier charge coupled devices, silicon photo multipliers, etc. are currently used. This technique could allow skipper CCDs to benefit new astronomical instruments, quantum imaging, exoplanet search and study, and quantum metrology.Fil: Chierchie, Fernando. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Investigaciones en Ingeniería Eléctrica "Alfredo Desages". Universidad Nacional del Sur. Departamento de Ingeniería Eléctrica y de Computadoras. Instituto de Investigaciones en Ingeniería Eléctrica "Alfredo Desages"; ArgentinaFil: Fernández Moroni, Guillermo. Fermi National Accelerator Laboratory; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Investigaciones en Ingeniería Eléctrica "Alfredo Desages". Universidad Nacional del Sur. Departamento de Ingeniería Eléctrica y de Computadoras. Instituto de Investigaciones en Ingeniería Eléctrica "Alfredo Desages"; ArgentinaFil: Stefanazzi, Leandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Investigaciones en Ingeniería Eléctrica "Alfredo Desages". Universidad Nacional del Sur. Departamento de Ingeniería Eléctrica y de Computadoras. Instituto de Investigaciones en Ingeniería Eléctrica "Alfredo Desages"; Argentina. Fermi National Accelerator Laboratory; Estados UnidosFil: Paolini, Eduardo Emilio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Bahía Blanca. Instituto de Investigaciones en Ingeniería Eléctrica "Alfredo Desages". Universidad Nacional del Sur. Departamento de Ingeniería Eléctrica y de Computadoras. Instituto de Investigaciones en Ingeniería Eléctrica "Alfredo Desages"; ArgentinaFil: Tiffenberg, Javier Sebastian. Fermi National Accelerator Laboratory; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Estrada, Juan. Fermi National Accelerator Laboratory; Estados UnidosFil: Cancelo, Gustavo Indalecio. Fermi National Accelerator Laboratory; Estados UnidosFil: Uemura, Sho. Universitat Tel Aviv; Israe

    Transient severe hypotension with once-weekly subcutaneous injection of teriparatide in osteoporotic patient : a case report and insight for the drug interaction between hypotensive agents and teriparatide

    Get PDF
    Teriparatide, a recombinant form of parathyroid hormone, were well recognized as a useful option for the treatment of the osteoporosis. Although some side effects of teriparatide include headache, nausea, dizziness, and limb pain were reported. Here we present a 80-year-old woman of transient asymptomatic hypotension with once-weekly subcutaneous injection of teriparatide for the treatment of osteoporosis with hypertension disease as acute-phase reactions. Systolic blood pressure decreased in both 30 min and 60 min after injection compared with before injection. Heart rate increased with passage of time. Statistically significant were observed among before, 30min, 60min after injection of teriparatide. Slight nausea was seen as subjective symptoms with the first and second injection after 30 min. This case indicates careful attention, at least 1 hr, was recommended with weekly subcutaneous injections of teriparatide in the treatment for osoteoproteic patient with hypertension decreases. This is a first report, to the best of our knowledge, to demonstrate the transient asymptomatic hypotension after once-weekly injection of teriparatide with hypertension disease. Transient hypotension occurred after injection of teriparatide during the treatment period and was asymptomatic except for the first 2 injections

    Stent-Jack Technique for Ruptured Vertebral Artery Dissecting Aneurysm Involving the Origin of Posterior Inferior Cerebellar Artery

    Get PDF
    We herein report a case of a ruptured vertebral artery dissecting aneurysm involving the origin of the posterior inferior cerebellar artery that was treated using the stent-jack technique. After parent artery occlusion of the distal vertebral artery, stenting of the posterior inferior cerebellar artery was performed. Further coiling was needed because distal vertebral artery recanalization occurred due to transformation of the coil mass. The stent-jack technique for a ruptured vertebral artery dissecting aneurysm involving the origin of the posterior inferior cerebellar artery is effective; however, careful attention to recanalization after stenting is needed due to transformation of the coil mass

    Retrospective Study of the Correlation Between Pathological Tumor Size and Survival After Curative Resection of T3 Pancreatic Adenocarcinoma: Proposal for Reclassification of the Tumor Extending Beyond the Pancreas Based on Tumor Size

    Get PDF
    BackgroundEven though most patients who undergo resection of pancreatic adenocarcinoma have T3 disease with extra-pancreatic tumor extension, T3 disease is not currently classified by tumor size. The aim of this study was to modify the current TNM classification of pancreatic adenocarcinoma to reflect the influence of tumor size.MethodsA total of 847 consecutive pancreatectomy patients were recruited from multiple centers. Optimum tumor size cutoff values were calculated by receiver operating characteristics analysis for tumors limited to the pancreas (T1/2) and for T3 tumors. In our modified TNM classification, stage II was divided into stages IIA (T3aN0M0), IIB (T3bN0M0), and IIC (T1-3bN1M0) using tumor size cutoff values. The usefulness of the new classification was compared with that of the current classification using Akaike’s information criterion (AIC).ResultsThe optimum tumor size cutoff value distinguishing T1 and T2 was 2 cm, while T3 was divided into T3a and T3b at a tumor size of 3 cm. The median survival time of the stages IIA, IIB, and IIC were 44.7, 27.6, and 20.3 months, respectively. There were significant differences of survival between stages IIA and IIB (P = 0.02) and between stages IIB and IIC (P = 0.03). The new classification showed better performance compared with the current classification based on the AIC value.ConclusionsThis proposed new TNM classification reflects the influence of tumor size in patients with extra-pancreatic tumor extension (T3 disease), and the classification is useful for predicting mortality

    SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

    Full text link
    We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as ``dark counts'': dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.Comment: 9 pages, 6 figures, 4 table

    Dark sectors 2016 Workshop: community report

    Get PDF
    This report, based on the Dark Sectors workshop at SLAC in April 2016, summarizes the scientific importance of searches for dark sector dark matter and forces at masses beneath the weak-scale, the status of this broad international field, the important milestones motivating future exploration, and promising experimental opportunities to reach these milestones over the next 5-10 years
    corecore