309 research outputs found
An optical readout for a fibre tracker
The performance of 16 and 64 channel photomultipliers coupled to
scintillating fibres has been tested. The devices are sensitive to single
photoelectrons, show little gain losses for magnetic fields up to 100 Gauss and
have moderate optical cross-talk. The maximum channel to channel gain
variations reach a factor two for the 16 channel version and a factor of four
for the 64 channel PM. The measurements and simulations indicate that the
photomultipliers are well suited for the light detection in fibre trackers.Comment: 11 pages, 9 picture
Gas gain and signal length measurements with a triple-GEM at different pressures of Ar-, Kr- and Xe-based gas mixtures
We investigate the gas gain behaviour of a triple-GEM configuration in gas
mixtures of argon, krypton and xenon with ten and thirty percent of carbon
dioxide at pressures between 1 and 3 bar. Since the signal widths affect the
dead time behaviour of the detector we present signal length measurements to
evaluate the use of the triple-GEM in time-resolved X-ray imaging.Comment: 19 pages, 21 figures, revised version, accepted for publication in
Nucl. Instr. and Meth.
Properties of Groove Chambers
Groove chambers with different pitch and gap height have been tested. Gas
amplifications of the order of a few times 10 have been obtained.
Combining a groove structure with a GEM pre-amplification foil a gas gain of
10 was reached. The device is robust and can be produced at low cost in
large sizes by a laser technique
Investigation of the performance of an optimised MicroCAT, a GEM and their combination by simulations and current measurements
A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche
charge multiplication in gas filled radiation detectors has been optimised with
respect to maximum electron transparency and minimum ion feedback. We report on
the charge transfer behaviour and the achievable gas gain of this device. A
three-dimensional electron and ion transfer simulation is compared to results
derived from electric current measurements. Similarly, we present studies of
the charge transfer behaviour of a GEM (Gas Electron Multiplier) by current
measurements and simulations. Finally, we investigate the combination of the
MicroCAT and the GEM by measurements with respect to the performance at
different voltage settings, gas mixtures and gas pressures.Comment: 26 pages, 32 figure
Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the Inner Tracking System of HERA-B
The results of five years of development of the inner tracking system of the
HERA-B experiment and first experience from the data taking period of the year
2000 are reported. The system contains 184 chambers, covering a sensitive area
of about 20 * 20 cm2 each. The detector is based on microstrip gas counters
(MSGCs) with diamond like coated (DLC) glass wafers and gas electron
multipliers (GEMs). The main problems in the development phase were gas
discharges in intense hadron beams and aging in a high radiation dose
environment. The observation of gas discharges which damage the electrode
structure of the MSGC led to the addition of the GEM as a first amplification
step. Spurious sparking at the GEM cannot be avoided completely. It does not
affect the GEM itself but can produce secondary damage of the MSGC if the
electric field between the GEM and the MSGC is above a threshold depending on
operation conditions. We observed that aging does not only depend on the dose
but also on the spot size of the irradiated area. Ar-DME mixtures had to be
abandoned whereas a mixture of 70% Ar and 30% CO2 showed no serious aging
effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements
indicate that the DLC of the MSGC is deteriorated by the gas amplification
process. As a consequence, long term gain variations are expected. The Inner
Tracker has successfully participated in the data taking at HERA-B during
summer 2000.Comment: 29 pages, 22 figure
Open and Hidden Charm Production in 920 GeV Proton-Nucleus Collisions
The HERA-B collaboration has studied the production of charmonium and open
charm states in collisions of 920 GeV protons with wire targets of different
materials. The acceptance of the HERA-B spectrometer covers negative values of
xF up to xF=-0.3 and a broad range in transverse momentum from 0.0 to 4.8
GeV/c. The studies presented in this paper include J/psi differential
distributions and the suppression of J/psi production in nuclear media.
Furthermore, production cross sections and cross section ratios for open charm
mesons are discussed.Comment: 5 pages, 9 figures, to be published in the proceedings of the 6th
International Conference on Hyperons, Charm & Beauty Hadrons (BEACH04),
Chicago, IL, June 27 - July 3, 200
Measurement of the J/Psi Production Cross Section in 920 GeV/c Fixed-Target Proton-Nucleus Interactions
The mid-rapidity (dsigma_(pN)/dy at y=0) and total sigma_(pN) production
cross sections of J/Psi mesons are measured in proton-nucleus interactions.
Data collected by the HERA-B experiment in interactions of 920 GeV/c protons
with carbon, titanium and tungsten targets are used for this analysis. The
J/Psi mesons are reconstructed by their decay into lepton pairs. The total
production cross section obtained is sigma_(pN)(J/Psi) = 663 +- 74 +- 46
nb/nucleon. In addition, our result is compared with previous measurements
Inclusive Production Cross Sections from 920 GeV Fixed Target Proton-Nucleus Collisions
Inclusive differential cross sections and
for the production of \kzeros, \lambdazero, and
\antilambda particles are measured at HERA in proton-induced reactions on C,
Al, Ti, and W targets. The incident beam energy is 920 GeV, corresponding to
GeV in the proton-nucleon system. The ratios of differential
cross sections \rklpa and \rllpa are measured to be and , respectively, for \xf . No significant dependence upon the
target material is observed. Within errors, the slopes of the transverse
momentum distributions also show no significant
dependence upon the target material. The dependence of the extrapolated total
cross sections on the atomic mass of the target material is
discussed, and the deduced cross sections per nucleon are
compared with results obtained at other energies.Comment: 17 pages, 7 figures, 5 table
Search for the Flavor-Changing Neutral Current Decay with the HERA-B Detector
We report on a search for the flavor-changing neutral current decay using events recorded with a dimuon trigger in
interactions of 920 GeV protons with nuclei by the HERA-B experiment. We find
no evidence for such decays and set a 90% confidence level upper limit on the
branching fraction .Comment: 17 pages, 4 figures (of which 1 double), paper to be submitted to
Physics Letters
TESLA Technical Design Report Part III: Physics at an e+e- Linear Collider
The TESLA Technical Design Report Part III: Physics at an e+e- Linear
ColliderComment: 192 pages, 131 figures. Some figures have reduced quality. Full
quality figures can be obtained from http://tesla.desy.de/tdr. Editors -
R.-D. Heuer, D.J. Miller, F. Richard, P.M. Zerwa
- …