8 research outputs found

    Knowledge and practice of smoking cessation services among health care workers in Abuja, Federal Capital Territory, Nigeria

    Get PDF
    Cigarette smoking cost the global economy billions of dollars and results in the death of millions of people yearly. Despite efforts at national, regional and global levels to control cigarette smoking, there is still much yet to be achieved. Brief intervention by health care workers to their smoking patients is one strategy that could be conducted anywhere, if the health care workers are trained and positively disposed towards smoking cessation. Thus, this study was designed to assess the knowledge, attitude and delivery of smoking cessation services among health care workers in Abuja.A cross sectional descriptive study design was used. Questionnaire was used to collect required information. Stata statistical software version 11 was used to describe the data and determine associations between knowledge, perception, delivery of smoking cessation services and sociodemographic characteristics using chi-square test.Only 5% of respondents ever received training on tobacco control. Awareness of interventions that enhance smoking cessation was: telephone quit lines (11%), pharmacotherapy (30.5%), behaviour therapy (34.2%) and brief intervention (51%). Only 4.3% of the respondents were not willing to support clients with tobacco cessation services. Being a physician and male were associated with higher knowledge of smoking cessation among the respondents (p < 0.05).In conclusion, there was poor perception and low capacity toprovide smoking cessation services among the respondents. There is need to improve the perception and capacity of health care workers to provide smoking cessation services.Keywords: Cigarette Smoking; Health care workers; knowledge; perception; attitude; smoking cessation; Abuja; Nigeri

    Determination of the antimicrobial susceptibility pattern of extended spectrum beta lactamase (esbl) producing and the non-esbl producing strains of Escherichia coli

    Get PDF
    Background: The extended spectrum beta lactamases producing bacteria are bacteria of great concern among Gram negative bacilli. Escherichia coli stand out as major carrier of this enzyme. The appropriate control of this resistance pattern depends on using the antimicrobial regimen of best choice. Therefore the value of the susceptibility profile of organism harboring this enzyme cannot be overemphasized.Objectives: To determine the antimicrobial susceptibility of extended spectrum beta lactamases (ESBL) producing and the non-ESBL producing strains of Escherichia coli from clinical isolates of Escherichia coli in University of Maiduguri Teaching Hospital.Methodology: Confirmed variants of Escherichia coli were screened and confirmed for ESBL possession. Subsequently, modified Kirby Bauer method was utilized to test for antibiotic susceptibility using the commercially available Oxoid single disc for some major antibiotics.Results: A total of 172 strains of Escherichia coli were identified during the study period. Out of this number; 131 were identified as ESBL positive while a total of 41 were ESBL negative. The highest sensitivity for both the ESBL positive and ESBL negative strains of Escherichia coli was observed with Imipenem followed closely by Gentamicin.Conclusion: The study reveals narrow choice of antibiotics for the ESBL positive isolates of Escherichia coli although Imipenem antibiotic still retains its sensitivity.Keywords: Cephalosporins, Resistance, Maiduguri, Nigeri

    Effect of Smoke-Free Legislation on Adult Smoking Behaviour in England in the 18 Months following Implementation

    Get PDF
    Comprehensive smoke-free legislation covering all enclosed public places and workplaces was implemented in England on 1 July 2007. This study examines the impact of this legislation on smoking prevalence, number of cigarettes smoked and location of smoking, controlling for secular trends through the end of 2008.Repeat cross sectional survey using nationally representative data from the Health Survey for England (HSE). In total there are 54,333 respondents from 2003-2008. Logit and linear regression models were used to examine the effect of the legislation on smoking prevalence and the number of cigarettes smoked daily among continuing smokers which took the underlying trend into account. Our finding suggest that smoking prevalence (current smoker) decreased from 25% in 2003 to 21% in 2008 (AOR = 0.96 per year, 95% CI = 0.95-0.98, P<0.01) and the mean number of cigarettes consumed daily by smokers decreased from 14.1 in 2003 to 13.1 in 2008 (coefficient for time trend = -0.28±0.06 SE cig/day per year, P<0.01). After adjusting for these trends the introduction of smoke-free legislation was not associated with additional reductions in smoking prevalence (AOR = 1.02, 95% CI = 0.94-1.11, P = 0.596) or daily cigarette use in smokers (0.42±0.28 SE; P = 0.142). The percentage of respondents reporting smoking 'at work' and 'inside pubs or bars' decreased significantly from 14% to 2% (p<0.001) and from 34% to 2% (p<0.001), respectively, after the legislation. The percentage reporting smoking 'inside restaurants, cafes, or canteens' decreased significantly from 9% to 1% (p<0.001) and 'inside their home' decreased significantly from 65% to 55% (p<0.01).There is widespread compliance with the smoke-free legislation in England, which has led to large drops in indoor smoking in all venues, including at home. Declines in smoking prevalence and consumption continued along existing trends; they did not accelerate during the 18 months immediately following implementation

    EXILL—a high-efficiency, high-resolution setup for γ\gamma-spectroscopy at an intense cold neutron beam facility

    Get PDF
    In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10(8) n s(−)(1)cm(−)(2) at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr(3):(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 10(5) Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr(3):(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of (133)Ba, (60)Co and (152)Eu as well as data from the reactions (27)Al(n,γ)(28)Al and (35)Cl(n,γ)(36)Cl in the energy range from 30 keV up to 10 MeV

    EXILL—a high-efficiency, high-resolution setup for γ-spectroscopy at an intense cold neutron beam facility

    No full text
    In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 108 n s−1cm−2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr3:(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 105 Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr3:(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of 133Ba, 60Co and 152Eu as well as data from the reactions 27Al(n,γ)28Al and 35Cl(n,γ)36Cl in the energy range from 30 keV up to 10 MeV

    EXILL - a high-efficiency, high-resolution setup for gamma-spectroscopy at an intense cold neutron beam facility

    No full text
    In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of gamma-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10(8) ns(-1)cm(2) at the target position and negligible neutron halo. The targetwas surrounded by an array of eight to ten anti-Compton shielded EXOGAMClover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr3:(Ce) detectors from the FATIMA collaboration. The detectorswere arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 x 10(5) Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr3:(Ce) detectors to analyze half-lives of excited levels in the pico-to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of Ba-133, Co-60 and Eu-152 as well as data from the reactions Al-27(n, gamma)Al-28 and Cl-35(n,gamma)Cl-36 in the energy range from 30 keV up to 10MeV
    corecore