545 research outputs found
Enfermedad respiratoria en vacas Holstein alimentadas con silaje de maíz: reporte de caso
An outbreak of respiratory distress was observed in Holstein cows immediately after consuming a new batch of corn-silage, presumably due to the presence of pneumotoxic gases. Signs were observed in 10% of the cows, and characterized as tachypnea, orthopneic position, cough and notable anxiety a few minutes after offering the silage. No deaths were recorded. Mild leucocytosis was observed in the hemogram. Nutritional analysis and nitrate determination of the corn-silage revealed usual values. Nitrous oxide and methane concentration were evaluated by gas chromatography and nitrogen oxides concentration directly with a portable device, resulting in acceptable values. Although high concentrations of toxic gases could not be evidenced in the air sampled on farm, the clinical signs observed coincide with those reported in cases of exposure to gases formed during corn silage processes. A greater emphasis is required in the evaluation of the corn to be ensiled, given the possible existence of factors that can generate the accumulation of potentially toxic gases for cattle that affect negatively their health and productivity.Se describe un brote de enfermedad respiratoria en vacas Holando Argentino, inmediatamente luego del consumo de un nuevo silaje de planta entera de maíz, presuntamente con presencia de gases neumotóxicos. Se observaron signos en el 10% de las vacas, caracterizados como taquipnea, posición ortopnéica, episodios de tos y ansiedad, unos minutos luego del ofrecimiento del silaje. No se registraron muertes. En el hemograma se observó leucocitosis leve. El análisis de calidad nutricional del alimento y la concentración de nitratos en el silaje de maíz resultó con los valores habituales. Se evaluó la concentración de óxido nitroso y metano en una muestra de silaje de maíz recolectada herméticamente por cromatografía gaseosa, así como la concentración de óxidos de nitrógeno in situ con un instrumento portátil, resultando en valores aceptables. Aunque no se pudieron evidenciar concentraciones de gases elevadas en el aire del silaje muestreado en el tambo, los signos clínicos observados coinciden con los casos reportados de exposición a gases que se forman durante la fermentación del ensilado. Se debería tener en cuenta la evaluación del maíz a ser ensilado, dadas las posibilidades de que se genere la acumulación de gases potencialmente tóxicos para el ganado, que puedan afectar negativamente su salud y productividad
Beam Test of Silicon Strip Sensors for the ZEUS Micro Vertex Detector
For the HERA upgrade, the ZEUS experiment has designed and installed a high
precision Micro Vertex Detector (MVD) using single sided micro-strip sensors
with capacitive charge division. The sensors have a readout pitch of 120
microns, with five intermediate strips (20 micron strip pitch). An extensive
test program has been carried out at the DESY-II testbeam facility. In this
paper we describe the setup developed to test the ZEUS MVD sensors and the
results obtained on both irradiated and non-irradiated single sided micro-strip
detectors with rectangular and trapezoidal geometries. The performances of the
sensors coupled to the readout electronics (HELIX chip, version 2.2) have been
studied in detail, achieving a good description by a Monte Carlo simulation.
Measurements of the position resolution as a function of the angle of incidence
are presented, focusing in particular on the comparison between standard and
newly developed reconstruction algorithms.Comment: 41 pages, 21 figures, 2 tables, accepted for publication in NIM
Individualized Prediction of Drug Resistance in People with Post-Stroke Epilepsy: A Retrospective Study
Background: The study aimed to develop a model and build a nomogram to predict the probability of drug resistance in people with post-stroke epilepsy (PSE). Methods: Subjects with epilepsy secondary to ischemic stroke or spontaneous intracerebral hemorrhage were included. The study outcome was the occurrence of drug-resistant epilepsy defined according to International League Against Epilepsy criteria. Results: One hundred and sixty-four subjects with PSE were included and 32 (19.5%) were found to be drug-resistant. Five variables were identified as independent predictors of drug resistance and were included in the nomogram: age at stroke onset (odds ratio (OR): 0.941, 95% confidence interval (CI) 0.907–0.977), intracerebral hemorrhage (OR: 6.292, 95% CI 1.957–20.233), severe stroke (OR: 4.727, 95% CI 1.573–14.203), latency of PSE (>12 months, reference; 7–12 months, OR: 4.509, 95% CI 1.335–15.228; 0–6 months, OR: 99.099, 95% CI 14.873–660.272), and status epilepticus at epilepsy onset (OR: 14.127, 95% CI 2.540–78.564). The area under the receiver operating characteristic curve of the nomogram was 0.893 (95% CI: 0.832–0.956). Conclusions: Great variability exists in the risk of drug resistance in people with PSE. A nomogram based on a set of readily available clinical variables may represent a practical tool for an individualized prediction of drug-resistant PSE
Nonalcoholic fatty liver disease and increased risk of 1-year all-cause and cardiac hospital readmissions in elderly patients admitted for acute heart failure
Nonalcoholic fatty liver disease (NAFLD) is an emerging risk factor for heart failure (HF). Although some progress has been made in improving survival among patients admitted for HF, the rates of hospital readmissions and the related costs continue to rise dramatically. We sought to examine whether NAFLD and its severity (diagnosed at hospital admission) was independently associated with a higher risk of 1-year all-cause and cardiac re-hospitalization in patients admitted for acute HF. We studied 212 elderly patients who were consecutively admitted with acute HF to the Hospital of Negrar (Verona) over a 1-year period. Diagnosis of NAFLD was based on ultrasonography, whereas the severity of advanced NAFLD fibrosis was based on the fibrosis (FIB)-4 score and other non-invasive fibrosis scores. Patients with acute myocardial infarction, severe valvular heart diseases, endstage renal disease, cancer, known liver diseases or decompensated cirrhosis were excluded. Cox regression was used to estimate hazard ratios (HR) for the associations between NAFLD and the outcome(s) of interest. The cumulative rate of 1-year all-cause re-hospitalizations was 46.7% (n = 99, mainly due to cardiac causes). Patients with NAFLD (n = 109; 51.4%) had remarkably higher 1-year all-cause and cardiac re-hospitalization rates compared with their counterparts without NAFLD. Both event rates were particularly increased in those with advanced NAFLD fibrosis. NAFLD was associated with a 5-fold increased risk of 1-year all-cause re-hospitalization (adjusted-hazard ratio 5.05, 95% confidence intervals 2.78-9.10, p<0.0001) after adjustment for established risk factors and potential confounders. Similar results were found for 1-year cardiac re-hospitalization (adjusted-hazard ratio 8.05, 95% confidence intervals 3.77-15.8, p<0.0001). In conclusion, NAFLD and its severity were strongly and independently associated with an increased risk of 1-year all-cause and cardiac re-hospitalization in elderly patients admitted with acute HF
Combined QCD and electroweak analysis of HERA data
A simultaneous fit of parton distribution functions (PDFs) and electroweak
parameters to HERA data on deep inelastic scattering is presented. The input
data are the neutral current and charged current inclusive cross sections which
were previously used in the QCD analysis leading to the HERAPDF2.0 PDFs. In
addition, the polarisation of the electron beam was taken into account for the
ZEUS data recorded between 2004 and 2007. Results on the vector and
axial-vector couplings of the Z boson to u- and d-type quarks, on the value of
the electroweak mixing angle and the mass of the W boson are presented. The
values obtained for the electroweak parameters are in agreement with Standard
Model predictions.Comment: 32 pages, 10 figures, accepted by Phys. Rev. D. Small corrections
from proofing process and small change to Fig. 12 and Table
Limits on the effective quark radius from inclusive scattering at HERA
The high-precision HERA data allows searches up to TeV scales for Beyond the
Standard Model contributions to electron-quark scattering. Combined
measurements of the inclusive deep inelastic cross sections in neutral and
charged current scattering corresponding to a luminosity of around 1
fb have been used in this analysis. A new approach to the beyond the
Standard Model analysis of the inclusive data is presented; simultaneous
fits of parton distribution functions together with contributions of "new
physics" processes were performed. Results are presented considering a finite
radius of quarks within the quark form-factor model. The resulting 95% C.L.
upper limit on the effective quark radius is cm.Comment: 10 pages, 4 figures, accepted by Phys. Lett.
Search for a narrow baryonic state decaying to and in deep inelastic scattering at HERA
A search for a narrow baryonic state in the and
system has been performed in collisions at HERA with the ZEUS detector
using an integrated luminosity of 358 pb taken in 2003-2007. The search
was performed with deep inelastic scattering events at an centre-of-mass
energy of 318 GeV for exchanged photon virtuality, , between 20 and 100
. Contrary to evidence presented for such a state around 1.52
GeV in a previous ZEUS analysis using a sample of 121 pb taken in
1996-2000, no resonance peak was found in the invariant-mass
distribution in the range 1.45-1.7 GeV. Upper limits on the production cross
section are set.Comment: 16 pages, 4 figures, accepted by Phys. Lett. B. Minor changes from
journal reviewing process, including a small correction to figure
Measurement of the cross-section ratio sigma_{psi(2S)}/sigma_{J/psi(1S)} in deep inelastic exclusive ep scattering at HERA
The exclusive deep inelastic electroproduction of and
at an centre-of-mass energy of 317 GeV has been studied with the ZEUS
detector at HERA in the kinematic range GeV,
GeV and GeV, where is the photon virtuality, is the
photon-proton centre-of-mass energy and is the squared four-momentum
transfer at the proton vertex. The data for GeV were taken in
the HERA I running period and correspond to an integrated luminosity of 114
pb. The data for GeV are from both HERA I and HERA II
periods and correspond to an integrated luminosity of 468 pb. The decay
modes analysed were and for the
and for the . The cross-section ratio
has been measured as a function of
and . The results are compared to predictions of QCD-inspired
models of exclusive vector-meson production.Comment: 24 pages, 8 figure
- …