274 research outputs found

    Spinal Anesthesia and Minimal Invasive Laminotomy for Paddle Electrode Placement in Spinal Cord Stimulation: Technical Report and Clinical Results at Long-Term Followup

    Get PDF
    Object. We arranged a mini-invasive surgical approach for implantation of paddle electrodes for SCS under spinal anesthesia obtaining the best paddle electrode placement and minimizing patients' discomfort. We describe our technique supported by neurophysiological intraoperative monitoring and clinical results. Methods. 16 patients, affected by neuropathic pain underwent the implantation of paddle electrodes for spinal cord stimulation in lateral decubitus under spinal anesthesia. The paddle was introduced after flavectomy and each patient confirmed the correct distribution of paresthesias induced by intraoperative test stimulation. VAS and patients' satisfaction rate were recorded during the followup and compared to preoperative values. Results. No patients reported discomfort during the procedure. In all cases, paresthesias coverage of the total painful region was achieved, allowing the best final electrode positioning. At the last followup (mean 36.7 months), 87.5% of the implanted patients had a good rate of satisfaction with a mean VAS score improvement of 70.5%. Conclusions. Spinal cord stimulation under spinal anesthesia allows an optimal positioning of the paddle electrodes without any discomfort for patients or neurosurgeons. The best intraoperative positioning allows a better postoperative control of pain, avoiding the risk of blind placements of the paddle or further surgery for their replacement

    Fate of Pharmaceuticals and Personal Care Products (PPCPs) from discharge to drinking water: a modelling and monitoring integrated framework

    Get PDF
    Pharmaceuticals and Personal Care Products (PPCPs) presence in drinking water is gaining growing concern for potential negative effects on human health. This study combined modelling of river transport with monitoring campaigns performed over one year at a drinking water treatment plant (DWTP) located at the closure section of Po river basin, to evaluate the types of released PPCPs, their concentrations and fate in both the river and the DWTP. Over the 114 monitored PPCPs, maximum 23 compounds have been detected at the DWTP inlet with concentrations from 10 to 1800 ng/L, varying among PPCPs and in time. The transport in Po river of iopamidol, with the highest concentration at the DWTP inlet, was simulated combining hydrological and quality data and models. Finally, DWTP monitoring showed that ozonation and adsorption onto activated carbon have the main impact in reducing a wide variety of PPCPs, with performances influenced by their characteristics

    A comparison between in vivo and ex vivo HR-MAS H-1 MR spectra of a pediatric posterior fossa lesion

    Get PDF
    The present case report was aimed at identifying the molecular profile characteristic of a primitive neuroectodermal tumor (PNET) in a 3-year-old child affected by a lesion localized in the cerebellar region. The histological diagnosis was medulloblastoma. In vivo single voxel H-1 magnetic resonance spectroscopy (MRS) shows high specificity in detecting the main metabolic alterations in the primitive cerebellar lesion; a very high amount of the choline-containing compounds and very low level of creatine derivatives and N-acetylaspartate. Ex vivo high resolution magic angle spinning (HR-MAS) H-1 magnetic resonance spectroscopy, performed at 9.4 Tesla on the neoplastic specimen collected during surgery, allows for the unambiguous identification of several metabolites giving a more in-depth evaluation of the metabolic pattern of the lesion. The ex vivo HR-MAS MR spectra show that the spectral detail is much higher than that obtained in vivo and that, for example, myo-inositol, taurine and phosphorylethanolamine contribute to the in vivo signal at 3.2 ppm, usually attributed to choline-containing compounds. In addition, the spectroscopic data appear to correlate with some morphological features of the medulloblastoma. Consequently, the present study shows that ex vivo HR-MAS H-1 MRS is able to strongly improve the clinical possibility of in vivo MRS and can be used in conjunction with in vivo spectroscopy for clinical purposes

    Trans-anal irrigation in patients with multiple sclerosis: Efficacy in treating disease-related bowel dysfunctions and impact on the gut microbiota: A monocentric prospective study

    Get PDF
    Background: Constipation and faecal incontinence are not so uncommon in patients with multiple sclerosis, impairing quality of life. The gut microbiota is altered in multiple sclerosis patients and likely contributes to disease pathogenesis. Trans-anal irrigation has been proven to allow treatment of neurogenic bowel dysfunction and may affect gut microbiota. Objectives: The primary outcome was trans-anal irrigation effectiveness on constipation and faecal incontinence. The secondary outcome was gut microbiota profiling compared to healthy subjects and during trans-anal irrigation adoption. Methods: We conducted a prospective cohort study on multiple sclerosis patients, screened with Patient Assessment of Constipation Quality of Life questionnaire before undergoing constipation and faecal incontinence scoring, abdomen X-ray for intestinal transit time, compilation of food and evacuation diaries and faecal sample collection for gut microbiota analysis before and after 4 weeks of trans-anal irrigation. Results and Conclusions: Eighty patients were screened of which nearly half had intestinal symptoms. The included population (n = 37) was predominantly composed of women with significantly longer disease duration, higher mean age and disability than the excluded one (p < 0.05). Twelve patients completed the trans-anal irrigation phase, which led to significant improvement of bowel dysfunction symptom-related quality of life, increase in gut microbiota diversity and reduction of the proportions of pro-inflammatory taxa (p < 0.05). Trans-anal irrigation was safe, satisfactory and could help counteract multiple sclerosis-related dysbiosis

    The cientificWorldJOURNAL Clinical Study Spinal Anesthesia and Minimal Invasive Laminotomy for Paddle Electrode Placement in Spinal Cord Stimulation: Technical Report and Clinical Results at Long-Term Followup

    Get PDF
    Object. We arranged a mini-invasive surgical approach for implantation of paddle electrodes for SCS under spinal anesthesia obtaining the best paddle electrode placement and minimizing patients' discomfort. We describe our technique supported by neurophysiological intraoperative monitoring and clinical results. Methods. 16 patients, affected by neuropathic pain underwent the implantation of paddle electrodes for spinal cord stimulation in lateral decubitus under spinal anesthesia. The paddle was introduced after flavectomy and each patient confirmed the correct distribution of paresthesias induced by intraoperative test stimulation. VAS and patients' satisfaction rate were recorded during the followup and compared to preoperative values. Results. No patients reported discomfort during the procedure. In all cases, paresthesias coverage of the total painful region was achieved, allowing the best final electrode positioning. At the last followup (mean 36.7 months), 87.5% of the implanted patients had a good rate of satisfaction with a mean VAS score improvement of 70.5%. Conclusions. Spinal cord stimulation under spinal anesthesia allows an optimal positioning of the paddle electrodes without any discomfort for patients or neurosurgeons. The best intraoperative positioning allows a better postoperative control of pain, avoiding the risk of blind placements of the paddle or further surgery for their replacement

    Discovery of diffuse emission in the galaxy cluster A1689

    Get PDF
    The aim of this work is to investigate the possible presence of extended diffuse synchrotron radio emission associated with the intracluster medium of the complex galaxy cluster A1689. The radio continuum emission of A1689 has been investigated by analyzing archival observations at 1.2 and 1.4 GHz obtained with the Very Large Array in different configurations. We report the detection of an extended, diffuse, low-surface brightness radio emission located in the central region of A1689. The surface brightness profile of the diffuse emission at 1.2 GHz indicates a central radio brightness of ~1.7 \mu Jy/arcsec^2 and the 3\sigma radio isophothes reveal the largest linear size to be 730 kpc. Given its central location, the low-level surface brightness, and the comparatively large extension, we classify the diffuse cluster-wide emission in A1689 as a small radio halo.Comment: 8 pages, 6 figures, A&A accepte

    Liver trauma: WSES position paper

    Get PDF
    The liver is the most injured organ in abdominal trauma. Road traffic crashes and antisocial, violent behavior account for the majority of liver injuries. The present position paper represents the position of the World Society of Emergency Surgery (WSES) about the management of liver injuries

    One year of surgical mask testing at the University of Bologna labs:Lessons learned from data analysis

    Get PDF
    The outbreak of SARS-CoV-2 pandemic highlighted the worldwide lack of surgical masks and personal protective equipment, which represent the main defense available against respiratory diseases as COVID-19. At the time, masks shortage was dramatic in Italy, the first European country seriously hit by the pandemic: aiming to address the emergency and to support the Italian industrial reconversion to the production of surgical masks, a multidisciplinary team of the University of Bologna organized a laboratory to test surgical masks according to European regulations. The group, driven by the expertise of chemical engineers, microbiologists, and occupational physicians, set-up the test lines to perform all the functional tests required. The laboratory started its activity on late March 2020, and as of the end of December of the same year 435 surgical mask prototypes were tested, with only 42 masks compliant to the European standard. From the analysis of the materials used, as well as of the production methods, it was found that a compliant surgical mask is most likely composed of three layers, a central meltblown filtration layer and two external spunbond comfort layers. An increase in the material thickness (grammage), or in the number of layers, does not improve the filtration efficiency, but leads to poor breathability, indicating that filtration depends not only on pure size exclusion, but other mechanisms are taking place (driven by electrostatic charge). The study critically reviewed the European standard procedures, identifying the weak aspects; among the others, the control of aerosol droplet size during the bacterial filtration test results to be crucial, since it can change the classification of a mask when its performance lies near to the limiting values of 95 or 98%
    corecore