124 research outputs found

    Experimental validation of 4D log file-based proton dose reconstruction for interplay assessment considering amplitude-sorted 4DCTs

    Get PDF
    Purpose The unpredictable interplay between dynamic proton therapy delivery and target motion in the thorax can lead to severe dose distortions. A fraction-wise four-dimensional (4D) dose reconstruction workflow allows for the assessment of the applied dose after patient treatment while considering the actual beam delivery sequence extracted from machine log files, the recorded breathing pattern and the geometric information from a 4D computed tomography scan (4DCT). Such an algorithm capable of accounting for amplitude-sorted 4DCTs was implemented and its accuracy as well as its sensitivity to input parameter variations was experimentally evaluated. Methods An anthropomorphic thorax phantom with a movable insert containing a target surrogate and a radiochromic film was irradiated with a monoenergetic field for various 1D target motion forms (sin, sin(4)) and peak-to-peak amplitudes (5/10/15/20/30 mm). The measured characteristic film dose distributions were compared to the respective sections in the 4D reconstructed doses using a 2D gamma-analysis (3 mm, 3%); gamma-pass rates were derived for different dose grid resolutions (1 mm/3 mm) and deformable image registrations (DIR, automatic/manual) applied during the 4D dose reconstruction process. In an additional analysis, the sensitivity of reconstructed dose distributions against potential asynchronous timing of the motion and machine log files was investigated for both a monoenergetic field and more realistic 4D robustly optimized fields by artificially introduced offsets of +/- 1/5/25/50/250 ms. The resulting dose distributions with asynchronized log files were compared to those with synchronized log files by means of a 3D gamma-analysis (1 mm, 1%) and the evaluation of absolute dose differences. Results The induced characteristic interplay patterns on the films were well reproduced by the 4D dose reconstruction with 2D gamma-pass rates >= 95% for almost all cases with motion magnitude

    Фінансовий контролінг як інструмент управління діяльністю суб'єкта господарювання

    Get PDF
    PURPOSE: Multiple imaging techniques are nowadays available for clinical in-vivo visualization of tumour biology. FDG PET/CT identifies increased tumour metabolism, hypoxia PET visualizes tumour oxygenation and dynamic contrast-enhanced (DCE) CT characterizes vasculature and morphology. We explored the relationships among these biological features in patients with non-small-cell lung cancer (NSCLC) at both the patient level and the tumour subvolume level. METHODS: A group of 14 NSCLC patients from two ongoing clinical trials (NCT01024829 and NCT01210378) were scanned using FDG PET/CT, HX4 PET/CT and DCE CT prior to chemoradiotherapy. Standardized uptake values (SUV) in the primary tumour were calculated for the FDG and hypoxia HX4 PET/CT scans. For hypoxia imaging, the hypoxic volume, fraction and tumour-to-blood ratio (TBR) were also defined. Blood flow and blood volume were obtained from DCE CT imaging. A tumour subvolume analysis was used to quantify the spatial overlap between subvolumes. RESULTS: At the patient level, negative correlations were observed between blood flow and the hypoxia parameters (TBR >1.2): hypoxic volume (−0.65, p = 0.014), hypoxic fraction (−0.60, p = 0.025) and TBR (−0.56, p = 0.042). At the tumour subvolume level, hypoxic and metabolically active subvolumes showed an overlap of 53 ± 36 %. Overlap between hypoxic sub-volumes and those with high blood flow and blood volume was smaller: 15 ± 17 % and 28 ± 28 %, respectively. Half of the patients showed a spatial mismatch (overlap <5 %) between increased blood flow and hypoxia. CONCLUSION: The biological imaging features defined in NSCLC tumours showed large interpatient and intratumour variability. There was overlap between hypoxic and metabolically active subvolumes in the majority of tumours, there was spatial mismatch between regions with high blood flow and those with increased hypoxia. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00259-015-3169-4) contains supplementary material, which is available to authorized users

    Epigenetics in radiotherapy: Where are we heading?

    Get PDF
    Radiotherapy is an important component of anti-cancer treatment. However, not all cancer patients respond to radiotherapy, and with current knowledge clinicians are unable to predict which patients are at high risk of recurrence after radiotherapy. There is therefore an urgent need for biomarkers to guide clinical decision-making. Although the importance of epigenetic alterations is widely accepted, their application as biomarkers in radiotherapy has not been studied extensively. In addition, it has been suggested that radiotherapy itself introduces epigenetic alterations. As epigenetic alterations can potentially be reversed by drug treatment, they are interesting candidate targets for anticancer therapy or radiotherapy sensitizers. The application of demethylating drugs or histone deacetylase inhibitors to sensitize patients for radiotherapy has been studied in vitro, in vivo as well as in clinical trials with promising results. This review describes the current knowledge on epigenetics in radiotherapy

    Proposal for the delineation of neoadjuvant target volumes in oesophageal cancer

    Get PDF
    PURPOSE: To define instructions for delineation of target volumes in the neoadjuvant setting in oesophageal cancer. MATERIALS AND METHODS: Radiation oncologists of five European centres participated in the following consensus process: [1] revision of published (MEDLINE) and national/institutional delineation guidelines; [2] first delineation round of five cases (patient 1-5) according to national/institutional guidelines; [3] consensus meeting to discuss the results of step 1 and 2, followed by a target volume delineation proposal; [4] circulation of proposed instructions for target volume delineation and atlas for feedback; [5] second delineation round of five new cases (patient 6-10) to peer review and validate (two additional centres) the agreed delineation guidelines and atlas; [6] final consensus on the delineation guidelines depicted in an atlas. Target volumes of the delineation rounds were compared between centres by Dice similarity coefficient (DSC) and maximum/mean undirected Hausdorff distances (Hmax/Hmean). RESULTS: In the first delineation round, the consistency between centres was moderate (CTVtotal: DSC = 0.59-0.88; Hmean = 0.2-0.4 cm). Delineations in the second round were much more consistent. Lowest variability was obtained between centres participating in the consensus meeting (CTVtotal: DSC: p < 0.050 between rounds for patients 6/7/8/10; Hmean: p < 0.050 for patients 7/8/10), compared to validation centres (CTVtotal: DSC: p < 0.050 between validation and consensus meeting centres for patients 6/7/8; Hmean: p < 0.050 for patients 7/10). A proposal for delineation of target volumes and an atlas were generated. CONCLUSION: We proposed instructions for target volume delineation and an atlas for the neoadjuvant radiation treatment in oesophageal cancer. These will enable a more uniform delineation of patients in clinical practice and clinical trials

    Combined tumor plus nontumor interim FDG‐PET parameters are prognostic for response to chemoradiation in squamous cell esophageal cancer

    Get PDF
    We have investigated the prognostic value of two novel interim F-18-fluorodeoxyglucose positron emission tomography (FDG-PET) parameters in patients undergoing chemoradiation (CRT) for esophageal squamous cell carcinoma (ESCC): one tumor parameter (maximal standardized uptake ratio rSUR) and one normal tissue parameter (change of FDG uptake within irradiated nontumor-affected esophagus increment SUVNTO). PET data of 134 European and Chinese patients were analyzed. Parameter establishment was based on 36 patients undergoing preoperative CRT plus surgery, validation was performed in 98 patients receiving definitive CRT. Patients received PET imaging prior and during fourth week of CRT. Clinical parameters, baseline PET parameters, and interim PET parameters (rSUR and increment SUVNTO) were analyzed and compared to event-free survival (EFS), overall survival (OS), loco-regional control (LRC) and freedom from distant metastases (FFDM). Combining rSUR and increment SUVNTO revealed a strong prognostic impact on EFS, OS, LRC and FFDM in patients undergoing preoperative CRT. In the definitive CRT cohort, univariate analysis with respect to EFS revealed several staging plus both previously established interim PET parameters as significant prognostic factors. Multivariate analyses revealed only rSUR and increment SUVNTO as independent prognostic factors (p = 0.003, p = 0.008). Combination of these parameters with the cutoff established in preoperative CRT revealed excellent discrimination of patients with a long or short EFS (73% vs. 17% at 2 years, respectively) and significantly discriminated all other endpoints (OS, p < 0.001; LRC, p < 0.001; FFDM, p = 0.02), even in subgroups. Combined use of interim FDG-PET derived parameters increment SUVNTO and rSUR seems to have predictive potential, allowing to select responders for definitive CRT and omission of surgery

    Role of Mobility Strategy in moderating the effect Of ERP performance to operational performance: (Study in Indonesian palm oil plantation industries)

    Get PDF
    Introduction: Inter-observer variability (IOV) in target volume delineation is a well-documented source of geometric uncertainty in radiotherapy. Such variability has not yet been explored in the context of adaptive re-delineation based on imaging data acquired during treatment. We compared IOV in the pre- and mid-treatment setting using expert primary gross tumour volume (GTV) and clinical target volume (CTV) delineations in locoregionally advanced head-and-neck squamous cell carcinoma (HNSCC) and (non-)small cell lung cancer [(N)SCLC]. Material and methods: Five and six observers participated in the HNSCC and (N)SCLC arm, respectively, and provided delineations for five cases each. Imaging data consisted of CT studies partly complemented by FDG-PET and was provided in two separate phases for pre- and mid-treatment. Global delineation compatibility was assessed with a volume overlap metric (the Generalised Conformity Index), while local extremes of IOV were identified through the standard deviation of surface distances from observer delineations to a median consensus delineation. Details of delineation procedures, in particular, GTV to CTV expansion and adaptation strategies, were collected through a questionnaire. Results: Volume overlap analysis revealed a worsening of IOV in all but one case per disease site, which failed to reach significance in this small sample (p-value range .063-.125). Changes in agreement were propagated from GTV to CTV delineations, but correlation could not be formally demonstrated. Surface distance based analysis identified longitudinal target extent as a pervasive source of disagreement for HNSCC. High variability in (N)SCLC was often associated with tumours abutting consolidated lung tissue or potentially invading the mediastinum. Adaptation practices were variable between observers with fewer than half stating that they consistently adapted pre-treatment delineations during treatment. Conclusion: IOV in target volume delineation increases during treatment, where a disparity in institutional adaptation practices adds to the conventional causes of IOV. Consensus guidelines are urgently needed

    Definition and validation of a radiomics signature for loco-regional tumour control in patients with locally advanced head and neck squamous cell carcinoma

    Full text link
    Purpose: To develop and validate a CT-based radiomics signature for the prognosis of loco-regional tumour control (LRC) in patients with locally advanced head and neck squamous cell carcinoma (HNSCC) treated by primary radiochemotherapy (RCTx) based on retrospective data from 6 partner sites of the German Cancer Consortium - Radiation Oncology Group (DKTK-ROG). Material and methods: Pre-treatment CT images of 318 patients with locally advanced HNSCC were col-lected. Four-hundred forty-six features were extracted from each primary tumour volume and then fil-tered through stability analysis and clustering. First, a baseline signature was developed from demographic and tumour-associated clinical parameters. This signature was then supplemented by CT imaging features. A final signature was derived using repeated 3-fold cross-validation on the discovery cohort. Performance in external validation was assessed by the concordance index (C-Index). Furthermore, calibration and patient stratification in groups with low and high risk for loco-regional recurrence were analysed. Results: For the clinical baseline signature, only the primary tumour volume was selected. The final sig-nature combined the tumour volume with two independent radiomics features. It achieved moderatel

    Individualized early death and long-term survival prediction after stereotactic radiosurgery for brain metastases of non-small cell lung cancer:Two externally validated nomograms

    Get PDF
    Introduction Commonly used clinical models for survival prediction after stereotactic radiosurgery (SRS) for brain metastases (BMs) are limited by the lack of individual risk scores and disproportionate prognostic groups. In this study, two nomograms were developed to overcome these limitations. Methods 495 patients with BMs of NSCLC treated with SRS for a limited number of BMs in four Dutch radiation oncology centers were identified and divided in a training cohort (n = 214, patients treated in one hospital) and an external validation cohort n = 281, patients treated in three other hospitals). Using the training cohort, nomograms were developed for prediction of early death (<3 months) and long-term survival (>12 months) with prognostic factors for survival. Accuracy of prediction was defined as the area under the curve (AUC) by receiver operating characteristics analysis for prediction of early death and long term survival. The accuracy of the nomograms was also tested in the external validation cohort. Results Prognostic factors for survival were: WHO performance status, presence of extracranial metastases, age, GTV largest BM, and gender. Number of brain metastases and primary tumor control were not prognostic factors for survival. In the external validation cohort, the nomogram predicted early death statistically significantly better (p < 0.05) than the unfavorable groups of the RPA, DS-GPA, GGS, SIR, and Rades 2015 (AUC = 0.70 versus range AUCs = 0.51–0.60 respectively). With an AUC of 0.67, the other nomogram predicted 1 year survival statistically significantly better (p < 0.05) than the favorable groups of four models (range AUCs = 0.57–0.61), except for the SIR (AUC = 0.64, p = 0.34). The models are available on www.predictcancer.org. Conclusion The nomograms predicted early death and long-term survival more accurately than commonly used prognostic scores after SRS for a limited number of BMs of NSCLC. Moreover these nomograms enable individualized probability assessment and are easy into use in routine clinical practice

    Current practice in proton therapy delivery in adult cancer patients across Europe

    Get PDF
    BACKGROUND AND PURPOSE Major differences exist among proton therapy (PT) centres regarding PT delivery in adult cancer patient. To obtain insight into current practice in Europe, we performed a survey among European PT centres. MATERIALS AND METHODS We designed electronic questionnaires for eight tumour sites, focusing on four main topics: 1) indications and patient selection methods; 2) reimbursement; 3) on-going or planned studies, 4) annual number of patients treated with PT. RESULTS Of 22 centres, 19 (86%) responded. In total, 4233 adult patients are currently treated across Europe annually, of which 46% consists of patients with central nervous system tumours (CNS), 15% head and neck cancer (HNC), 15% prostate, 9% breast, 5% lung, 5% gastrointestinal, 4% lymphoma, 0.3% gynaecological cancers. CNS are treated in all participating centres (n = 19) using PT, HNC in 16 centres, lymphoma in 10 centres, gastrointestinal in 10 centres, breast in 7 centres, prostate in 6 centres, lung in 6 centres, and gynaecological cancers in 3 centres. Reimbursement is provided by national health care systems for the majority of commonly treated tumour sites. Approximately 74% of centres enrol patients for prospective data registration programs. Phase II-III trials are less frequent, due to reimbursement and funding problems. Reasons for not treating certain tumour types with PT are lack of evidence (30%), reimbursement issues (29%) and/or technical limitations (20%). CONCLUSION Across European PT centres, CNS tumours and HNC are the most frequently treated tumour types. Most centres use indication protocols. Lack of evidence for PT and reimbursement issues are the most reported reasons for not treating specific tumour types with PT
    corecore