8 research outputs found

    Integrated Acceptance Model for On-demand Car Functions: exploring determinants of drivers' acceptance

    Get PDF
    This research paper investigates the factors influencing drivers' acceptance of on-demand car functions (ODCFs) and proposes an integrated acceptance model specific to the ODCFs context. While limited marketing research has explored consumer responses to ODCFs, understanding the determinants of consumers' intention to accept ODCFs is crucial. Existing acceptance models, although effective in explaining variances in consumer behavior, need to be adapted and extended to enhance explanatory power in individual contexts. To address this gap, a comprehensive literature review on ODCFs and related domains was conducted, identifying 74 acceptance factors. Drawing upon the Unified Theory of Acceptance and Use of Technology (UTAUT), the Car Technology Acceptance Model (CTAM), and the identified factors, a multi-level acceptance model tailored to the ODCFs context was developed. At the meso-level, the baseline model incorporates factors such as exposure to ODCFs, domain-specific, symbolic-affective, and moral-normative factors. The micro-level pertains to distinct individual variance components, encompassing socio-demographic attributes, travel behavioral patterns, personality dispositions, and technological inclinations. These micro-level determinants exert a discernible influence on the factors situated at the meso-level of analysis. A partial model that considers cross-level influences and advocates for multi-level research to examine the contextual factors' impacts on acceptance empirically is proposed to operationalize the model. By adopting this approach, researchers can gain deeper insights into the acceptance of ODCFs and shed light on the mechanisms underlying consumer behavior in this specific context

    Higher resuscitation guideline adherence in paramedics with use of real-time ventilation feedback during simulated out-of-hospital cardiac arrest : a randomised controlled trial

    Get PDF
    To investigate whether real-time ventilation feedback would improve provider adherence to ventilation guidelines. Non-blinded randomised controlled simulation trial. One Emergency Medical Service trust in Copenhagen. 32 ambulance crews consisting of 64 on-duty basic or advanced life support paramedics from Copenhagen Emergency Medical Service. Participant exposure to real-time ventilation feedback during simulated out-of-hospital cardiac arrest. The primary outcome was ventilation quality, defined as ventilation guideline-adherence to ventilation rate (8-10 bpm) and tidal volume (500-600 ml) delivered simultaneously. The intervention group performed ventilations in adherence with ventilation guideline recommendations for 75.3% (Interquartile range (IQR) 66.2%-82.9%) of delivered ventilations, compared to 22.1% (IQR 0%-44.0%) provided by the control group. When controlling for participant covariates, adherence to ventilation guidelines was 44.7% higher in participants receiving ventilation feedback. Analysed separately, the intervention group performed a ventilation guideline-compliant rate in 97.4% (IQR 97.1%-100%) of delivered ventilations, versus 66.7% (IQR 40.9%-77.9%) for the control group. For tidal volume compliance, the intervention group reached 77.5% (IQR 64.9%-83.8%) of ventilations within target compared to 53.4% (IQR 8.4%-66.7%) delivered by the control group. Real-time ventilation feedback increased guideline compliance for both ventilation rate and tidal volume (combined and as individual parameters) in a simulated OHCA setting. Real-time feedback has the potential to improve manual ventilation quality and may allow providers to avoid harmful hyperventilation. [Abstract copyright: © 2021 The Authors.

    International variation in survival after out-of-hospital cardiac arrest : A validation study of the Utstein template

    Get PDF
    Introduction: Out-of-hospital cardiac arrest (OHCA) survival varies greatly between communities. The Utstein template was developed and promulgated to improve the comparability of OHCA outcome reports, but it has undergone limited empiric validation. We sought to assess how much of the variation in OHCA survival between emergency medical services (EMS) across the globe is explained by differences in the Utstein factors. We also assessed how accurately the Utstein factors predict OHCA survival. Methods: We performed a retrospective analysis of patient-level prospectively collected data from 12 OHCA registries from 12 countries for the period 1 Jan 2006 through 31 Dec 2011. We used generalized linear mixed models to examine the variation in survival between EMS agencies (n = 232). Results: Twelve registries contributed 86,759 cases. Patient arrest characteristics, EMS treatment and patient outcomes varied across registries. Overall survival to hospital discharge was 10% (range, 6% to 22%). Overall survival with Cerebral Performance Category of 1 or 2 (available for 8/12 registries) was 8%(range, 2% to 20%). The area-under-the-curve for the Utstein model was 0.85 (Wald CI: 0.85-0.85). The Utstein factors explained 51% of the EMS agency variation in OHCA survival. Conclusions: The Utstein factors explained 51%. of the variation in survival to hospital discharge among multiple large geographically separate EMS agencies. This suggests that quality improvement and public health efforts should continue to target modifiable Utstein factors to improve OHCA survival. Further study is required to identify the reasons for the variation that is incompletely understood.Peer reviewe

    EuReCa ONE—27 Nations, ONE Europe, ONE Registry A prospective one month analysis of out-of-hospital cardiac arrest outcomes in 27 countries in Europe

    Get PDF
    AbstractIntroductionThe aim of the EuReCa ONE study was to determine the incidence, process, and outcome for out of hospital cardiac arrest (OHCA) throughout Europe.MethodsThis was an international, prospective, multi-centre one-month study. Patients who suffered an OHCA during October 2014 who were attended and/or treated by an Emergency Medical Service (EMS) were eligible for inclusion in the study. Data were extracted from national, regional or local registries.ResultsData on 10,682 confirmed OHCAs from 248 regions in 27 countries, covering an estimated population of 174 million. In 7146 (66%) cases, CPR was started by a bystander or by the EMS. The incidence of CPR attempts ranged from 19.0 to 104.0 per 100,000 population per year. 1735 had ROSC on arrival at hospital (25.2%), Overall, 662/6414 (10.3%) in all cases with CPR attempted survived for at least 30 days or to hospital discharge.ConclusionThe results of EuReCa ONE highlight that OHCA is still a major public health problem accounting for a substantial number of deaths in Europe.EuReCa ONE very clearly demonstrates marked differences in the processes for data collection and reported outcomes following OHCA all over Europe. Using these data and analyses, different countries, regions, systems, and concepts can benchmark themselves and may learn from each other to further improve survival following one of our major health care events

    Apples to apples or apples to oranges? International variation in reporting of process and outcome of care for out-of-hospital cardiac arrest

    No full text
    Objectives: Survival after out-of-hospital cardiac arrest (OHCA) varies between communities, due in part to variation in the methods of measurement. The Utstein template was disseminated to standardize comparisons of risk factors, quality of care, and outcomes in patients with OHCA. We sought to assess whether OHCA registries are able to collate common data using the Utstein template. A subsequent study will assess whether the Utstein factors explain differences in survival between emergency medical services (EMS) systems. Study design: Retrospective study. Setting: This retrospective analysis of prospective cohorts included adults treated for OHCA, regardless of the etiology of arrest. Data describing the baseline characteristics of patients, and the process and outcome of their care were grouped by EMS system, de-identified, and then collated. Included were core Utstein variables and timed event data from each participating registry. This study was classified as exempt from human subjects’ research by a research ethics committee. Measurements and main results: Thirteen registries with 265 first-responding EMS agencies in 13 countries contributed data describing 125,840 cases of OHCA. Variation in inclusion criteria, definition, coding, and process of care variables were observed. Contributing registries collected 61.9% of recommended core variables and 42.9% of timed event variables. Among core variables, the proportion of missingness was mean 1.9 ± 2.2%. The proportion of unknown was mean 4.8 ± 6.4%. Among time variables, missingness was mean 9.0 ± 6.3%. Conclusions: International differences in measurement of care after OHCA persist. Greater consistency would facilitate improved resuscitation care and comparison within and between communities

    EuReCa ONE⿿27 Nations, ONE Europe, ONE Registry

    No full text
    corecore