2,874 research outputs found

    The detection of tightly closed flaws by nondestructive testing (NDT) methods

    Get PDF
    Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability

    Detection of tightly closed flaws by nondestructive testing (NDT) methods in steel and titanium

    Get PDF
    X-radiographic, liquid penetrant, ultrasonic, eddy current and magnetic particle testing techniques were optimized and applied to the evaluation of 4340 steel (180 KSI-UTS) and 6Al-4V titanium (STA) alloy specimens. Sixty steel specimens containing a total of 176 fatigue cracks and 60 titanium specimens containing a total of 135 fatigue cracks were evaluated. The cracks ranged in length from .043 cm (0.017 inch) to 1.02 cm (.400 inch) and in depth from .005 cm (.002 inch) to .239 cm (.094 inch) for steel specimens. Lengths ranged from .048 cm (0.019 inch) to 1.03 cm (.407 inch) and depths from 0.010 cm (.004 inch) to .261 cm (0.103 inch) for titanium specimens. Specimen thicknesses were nominally .152 cm (0.060 inch) and 0.635 cm (0.250 inch) and surface finishes were nominally 125 rms. Specimens were evaluated in the "as machined" surface condition, after etch surface and after proof loading in a randomized inspection sequence

    Definition of mutually optimum NDI and proof test criteria for 2219 aluminum pressure vessels. Volume 3: Applications to rail defect evaluation

    Get PDF
    The technique for inspection of railroad rails containing transverse fissure defects was discussed. Both pulse-echo and pitch-catch inspection techniques were used. The pulse-echo technique results suggest that a multiple-scan approach using varying angles of inclination, three-surface scanning, and dual-direction traversing may offer promise of characterization of transverse defects. Because each scan is likely to produce a reflection indicating only a portion of the defect, summing of the individual reflections must be used to obtain a reasonably complete characterization of the defect. The ability of the collimated pitch-catch technique to detect relatively small amounts of flaw growth was shown. The method has a problem in characterizing the portions of the defect near the top surface or web intersection. The work performed was a preliminary evaluation of the prospects for automated mapping of rail flaws

    Survey of International Space Station Charging Events

    Get PDF
    With the negative grounding of the 160V Photovoltaic (PV) arrays, the International Space Station (ISS) can experience varied and interesting charging events. Since August 2006, there has been a multi-probe p ackage, called the Floating Potential Measurement Unit (FPMU), availa ble to provide redundant measurements of the floating potential of th e ISS as well as the density and temperature of the local plasma environment. The FPMU has been operated during intermittent data campaigns since August 2006 and has collected over 160 days of information reg arding the charging of the ISS as it has progressed in configuration from one to three PV arrays and with various additional modules such as the European Space Agency?s Columbus laboratory and the Japan Aeros pace Exploration Agency's Kibo laboratory. This paper summarizes the charging of the ISS and the local environmental conditions that contr ibute to those charging events, both as measured by the FPMU

    Functional Dissection of Streptococcus pyogenes M5 Protein: the Hypervariable Region is Essential for Virulence

    Get PDF
    The surface-localized M protein of Streptococcus pyogenes is a major virulence factor that inhibits phagocytosis, as determined ex vivo. Because little is known about the role of M protein in vivo we analyzed the contribution of different M protein regions to virulence, using the fibrinogen (Fg)-binding M5 protein and a mouse model of acute invasive infection. This model was suitable, because M5 is required for mouse virulence and binds mouse and human Fg equally well, as shown here. Mixed infection experiments with wild type bacteria demonstrated that mutants lacking the N-terminal hypervariable region (HVR) or the Fg-binding B-repeat region were strongly attenuated, while a mutant lacking the conserved C-repeats was only slightly attenuated. Because the HVR of M5 is not required for phagocytosis resistance, our data imply that this HVR plays a major but unknown role during acute infection. The B-repeat region is required for phagocytosis resistance and specifically binds Fg, suggesting that it promotes virulence by binding Fg. However, B-repeat mutants were attenuated even in Fg-deficient mice, implying that the B-repeats may have a second function, in addition to Fg-binding. These data demonstrate that two distinct M5 regions, including the HVR, are essential to virulence during the early stages of an infection. In particular, our data provide the first in vivo evidence that the HVR of an M protein plays a major role in virulence, focusing interest on the molecular role of this region

    The First Definitive Binary Orbit Determined with the Hubble Space Telescope Fine Guidance Sensors: Wolf 1062 (Gliese 748)

    Get PDF
    The M dwarf binary, Wolf 1062 (Gliese 748), has been observed with the Hubble Space Telescope (HST) Fine Guidance Sensor 3 in the transfer function scan mode to determine the apparent orbit. This is the first orbit defined fully and exclusively with HST, and is the most accurate definitive orbit for any resolved, noneclipsing system. The orbital period is 2.4490 ± 0.0119 yr and the semimajor axis is 01470 ± 00007—both quantities are now known to better than 1%. Using the weighted mean of seven parallax measurements and these HST data, we find the system mass to be 0.543 ± 0.031 M⊙, where the error of 6% is due almost entirely to the parallax error. An estimated fractional mass from the infrared brightness ratio and infrared mass-luminosity relation yields a mass for the primary of 0.37 M⊙, and the secondary falls in the regime of very low mass stars, with a mass of only 0.17 M⊙

    Child Mortality in Rural Malawi: HIV Closes the Survival Gap between the Socio-Economic Strata

    Get PDF
    BACKGROUND: As HIV-related deaths increase in a population the usual association between low socioeconomic status and child mortality may change, particularly as death rates from other causes decline. METHODS/PRINCIPAL FINDINGS: As part of a demographic surveillance system in northern Malawi in 2002-6, covering a population of 32,000, information was collected on socio-economic status of the households. Deaths were classified as HIV/AIDS-related or not by verbal autopsy. Poisson regression models were used to assess the association of socio-economic indicators with all-cause mortality, AIDS-mortality and non-AIDS mortality among children. There were 195 deaths in infants, 109 in children aged 1-4 years, and 38 in children aged 5-15. All-cause child mortality in infants and 1-4 year olds was similar in households with higher and lower socio-economic status. In infants 13% of deaths were attributed to AIDS, and there were no clear trends with socio-economic status for AIDS or non-AIDS causes. For 1-4 year olds 27% of deaths were attributed to AIDS. AIDS mortality was higher among those with better built houses, and lowest in those with income from farming and fishing, whereas non-AIDS mortality was higher in those with worse built houses, lowest in those with income from employment, and decreased with increasing household assets. CONCLUSIONS/SIGNIFICANCE: In this population, since HIV infection among adults was initially more common among the less poor, childhood mortality patterns have changed. The usual gap in survival between the poor and the less poor has been lost, but because the less poor have been disproportionately affected by HIV, rather than because of relative improvement in the survival of the poorest

    A Critical Review of Biomarkers Used for Monitoring Human Exposure to Lead: Advantages, Limitations, and Future Needs

    Get PDF
    Lead concentration in whole blood (BPb) is the primary biomarker used to monitor exposure to this metallic element. The U.S. Centers for Disease Control and Prevention and the World Health Organization define a BPb of 10 μg/dL (0.48 μmol/L) as the threshold of concern in young children. However, recent studies have reported the possibility of adverse health effects, including intellectual impairment in young children, at BPb levels < 10 μg/dL, suggesting that there is no safe level of exposure. It appears impossible to differentiate between low-level chronic Pb exposure and a high-level short Pb exposure based on a single BPb measurement; therefore, serial BPb measurements offer a better estimation of possible health outcomes. The difficulty in assessing the exact nature of Pb exposure is dependent not so much on problems with current analytical methodologies, but rather on the complex toxicokinetics of Pb within various body compartments (i.e., cycling of Pb between bone, blood, and soft tissues). If we are to differentiate more effectively between Pb stored in the body for years and Pb from recent exposure, information on other biomarkers of exposure may be needed. None of the current biomarkers of internal Pb dose have yet been accepted by the scientific community as a reliable substitute for a BPb measurement. This review focuses on the limitations of biomarkers of Pb exposure and the need to improve the accuracy of their measurement. We present here only the traditional analytical protocols in current use, and we attempt to assess the influence of confounding variables on BPb levels. Finally, we discuss the interpretation of BPb data with respect to both external and endogenous Pb exposure, past or recent exposure, as well as the significance of Pb determinations in human specimens including hair, nails, saliva, bone, blood (plasma, whole blood), urine, feces, and exfoliated teeth
    corecore