15 research outputs found

    The Armeo Spring as training tool to improve upper limb functionality in multiple sclerosis: a pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Few research in multiple sclerosis (MS) has focused on physical rehabilitation of upper limb dysfunction, though the latter strongly influences independent performance of activities of daily living. Upper limb rehabilitation technology could hold promise for complementing traditional MS therapy. Consequently, this pilot study aimed to examine the feasibility of an 8-week mechanical-assisted training program for improving upper limb muscle strength and functional capacity in MS patients with evident paresis.</p> <p>Methods</p> <p>A case series was applied, with provision of a training program (3×/week, 30 minutes/session), supplementary on the customary maintaining care, by employing a gravity-supporting exoskeleton apparatus (Armeo Spring). Ten high-level disability MS patients (Expanded Disability Status Scale 7.0-8.5) actively performed task-oriented movements in a virtual real-life-like learning environment with the affected upper limb. Tests were administered before and after training, and at 2-month follow-up. Muscle strength was determined through the Motricity Index and Jamar hand-held dynamometer. Functional capacity was assessed using the TEMPA, Action Research Arm Test (ARAT) and 9-Hole Peg Test (9HPT).</p> <p>Results</p> <p>Muscle strength did not change significantly. Significant gains were particularly found in functional capacity tests. After training completion, TEMPA scores improved (<it>p </it>= 0.02), while a trend towards significance was found for the 9HPT (<it>p </it>= 0.05). At follow-up, the TEMPA as well as ARAT showed greater improvement relative to baseline than after the 8-week intervention period (<it>p </it>= 0.01, <it>p </it>= 0.02 respectively).</p> <p>Conclusions</p> <p>The results of present pilot study suggest that upper limb functionality of high-level disability MS patients can be positively influenced by means of a technology-enhanced physical rehabilitation program.</p

    Flemish Breast Cancer Screening programme : is stratification of women according to breast density indicated?

    No full text

    Tumour characteristics of screen-detected and interval cancers in the Flemish Breast Cancer Screening Programme : a mammographic breast density study

    No full text
    Objective: The objective is to investigate tumour prognostic factors versus breast density in screen-detected cancers and interval cancers. The results may highlight the need for more personalised screening protocols based on breast density in organized screening programmes.Study design: A retrospective study was performed of tumour characteristics of screen-detected cancers (n=468) and interval cancers (n=515) of 983 women who participated in the Flemish Breast Cancer Screening Programme in 2009-2010. Breast density was obtained from the screening programme data. Information on nodal invasion and histological grading was taken from the Belgian Cancer Registry. Tumour size and proliferation and receptor expression status were retrieved from pathology reports. The differences in tumour characteristics between screen-detected and interval cancers as well as the variation in these variables with breast density in both groups were studied by logistic regression.Results: A comparison of tumour characteristics between screen-detected cancers and interval cancers systematically showed features of more aggressive tumours in interval cancers: larger tumour size, nodal invasion, grade 3 tumours, and hormone receptor negative phenotype (p < 0.05). The analysis of tumour characteristics versus breast density in screen-detected cancers showed higher numbers of aggressive grade 3 tumours in low density breasts and of the luminal A subtype with good prognosis in high-density breasts (p < 0.05). This analysis for interval cancers highlights a high proportion of the difficult-to-treat triple-negative subtype in low-density breasts compared with high-density breasts. In conclusion, the study data support arguments against changes in breast cancer screening programmes with prolongation of screening intervals in low-density breasts

    Screen-detected versus interval cancers : effect of imaging modality and breast density in the Flemish Breast Cancer Screening Programme

    No full text
    To investigate if direct radiography (DR) performs better than screen-film mammography (SF) and computed radiography (CR) in dense breasts in a decentralized organised Breast Cancer Screening Programme. To this end, screen-detected versus interval cancers were studied in different BI-RADS density classes for these imaging modalities. The study cohort consisted of 351,532 women who participated in the Flemish Breast Cancer Screening Programme in 2009 and 2010. Information on screen-detected and interval cancers, breast density scores of radiologist second readers, and imaging modality was obtained by linkage of the databases of the Centre of Cancer Detection and the Belgian Cancer Registry. Overall, 67% of occurring breast cancers are screen detected and 33% are interval cancers, with DR performing better than SF and CR. The interval cancer rate increases gradually with breast density, regardless of modality. In the high-density class, the interval cancer rate exceeds the cancer detection rate for SF and CR, but not for DR. DR is superior to SF and CR with respect to cancer detection rates for high-density breasts. To reduce the high interval cancer rate in dense breasts, use of an additional imaging technique in screening can be taken into consideration

    Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme

    No full text
    To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30 % in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. * Performance parameters showed no major differences after digitalisation to CR or DR. * Transition from SFM to CR results in a higher mean glandular dose. * Transition from SFM to DR results in a lower mean glandular dose

    Letter to the Editor concerning the article “Application of red light phototherapy in the treatment of radioactive dermatitis in patients with head and neck cancer”

    No full text
    Abstract The aim of this Letter to the Editor was to report some methodological shortcomings in the recently published article “Application of red light phototherapy in the treatment of radioactive dermatitis in patients with head and neck cancer” by Zhang et al. There are some issues regarding the incomplete photobiomodulation (PBM) parameters, the chosen outcome measures, and some missing reference articles. In conclusion, the results of this study should be interpreted with caution and further research is necessary
    corecore