1,328 research outputs found

    Effects of Cl on the reduction of supported PdO in ethanol/water solvent mixtures

    Get PDF
    The reduction of γ-Al2O3-supported PdO in flowing aqueous ethanol was investigated. Quick EXAFS (QEXAFS) performed at the Pd K-edge reveals that the presence of Cl can have a profound effect on the reduction process. At low loadings of Pd (1 wt-%), the size dependency of the process is inverted, compared to Cl-free samples. The extent of reduction was found to be dependent on loading/particles size. It is shown, using in situ QEXAFS at the Cl K- and Pd L3-edges, that residual Cl is not removed by the flowing solvent mixture, even at an elevated temperature of 350 K. The origins of these behaviours are discussed in terms of the differing effects that Cl may have when bonded to oxidic or reduced metal centres and the results were compared to earlier observations made on the effects of Cl on commercial polyurea encapsulated Pd ENCAT™ NP 30 catalysts

    Effect of retained chlorine in ENCAT™ 30 catalysts on the development of encapsulated Pd: insights from in situ Pd K, L₃ and Cl K-edge XAS

    Get PDF
    In situ X-ray absorption spectroscopy (XAS) and Pd K, LIII, and Cl K-edges shows that Cl can be present in significant amounts in ENCATâ„¢ 30 catalysts and that it can severely retard Pd nanoparticle (NP) development in flowing solvents. We also show that whilst polymeric encapsulation protects the Pd against solvent induced agglomeration of Pd nanoparticles the evidence suggests it does not prevent the formation PdHx through reaction with the aqeous ethanol solvent, and that, as received, ENCATâ„¢ 30 NP catalysts are not, for the most part, comprised of nanoparticulate Pd0 irrespective of the presence of Cl

    High Energy Gamma-Ray Emission From Blazars: EGRET Observations

    Get PDF
    We will present a summary of the observations of blazars by the Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (CGRO). EGRET has detected high energy gamma-ray emission at energies greater than 100 MeV from more that 50 blazars. These sources show inferred isotropic luminosities as large as 3×10493\times 10^{49} ergs s−1^{-1}. One of the most remarkable characteristics of the EGRET observations is that the gamma-ray luminosity often dominates the bolometric power of the blazar. A few of the blazars are seen to exhibit variability on very short time-scales of one day or less. The combination of high luminosities and time variations seen in the gamma-ray data indicate that gamma-rays are an important component of the relativistic jet thought to characterize blazars. Currently most models for blazars involve a beaming scenario. In leptonic models, where electrons are the primary accelerated particles, gamma-ray emission is believed to be due to inverse Compton scattering of low energy photons, although opinions differ as to the source of the soft photons. Hardronic models involve secondary production or photomeson production followed by pair cascades, and predict associated neutrino production.Comment: 16 pages, 7 figures, style files included. Invited review paper in "Observational Evidence for Black Holes in the Universe," 1999, ed. S. K. Chakrabarti (Dordrecht: Kluwer), 215-23

    Entangled-State Cycles of Atomic Collective-Spin States

    Get PDF
    We study quantum trajectories of collective atomic spin states of NN effective two-level atoms driven with laser and cavity fields. We show that interesting ``entangled-state cycles'' arise probabilistically when the (Raman) transition rates between the two atomic levels are set equal. For odd (even) NN, there are (N+1)/2(N+1)/2 (N/2N/2) possible cycles. During each cycle the NN-qubit state switches, with each cavity photon emission, between the states (∣N/2,m>±∣N/2,−m>)/2(|N/2,m>\pm |N/2,-m>)/\sqrt{2}, where ∣N/2,m>|N/2,m> is a Dicke state in a rotated collective basis. The quantum number mm (>0>0), which distinguishes the particular cycle, is determined by the photon counting record and varies randomly from one trajectory to the next. For even NN it is also possible, under the same conditions, to prepare probabilistically (but in steady state) the Dicke state ∣N/2,0>|N/2,0>, i.e., an NN-qubit state with N/2N/2 excitations, which is of particular interest in the context of multipartite entanglement.Comment: 10 pages, 9 figure

    Human cryptochrome exhibits light-dependent magnetosensitivity

    Get PDF
    Humans are not believed to have a magnetic sense, even though many animals use the Earth's magnetic field for orientation and navigation. One model of magnetosensing in animals proposes that geomagnetic fields are perceived by light-sensitive chemical reactions involving the flavoprotein cryptochrome (CRY). Here we show using a transgenic approach that human CRY2, which is heavily expressed in the retina, can function as a magnetosensor in the magnetoreception system of Drosophila and that it does so in a light-dependent manner. The results show that human CRY2 has the molecular capability to function as a light-sensitive magnetosensor and reopen an area of sensory biology that is ready for further exploration in humans

    A descriptive study of UK cancer genetics services: an emerging clinical response to the new genetics

    Get PDF
    The objective was to describe NHS cancer genetic counselling services and compare UK regions. The study design was a cross-sectional study over 4 weeks and attendee survey. The setting was 22 of the 24 regional cancer genetics services in the UK NHS. Participants were individuals aged over 18 attending clinics at these services. Outcome measures were staff levels, referral rates, consultation rates, follow-up plans, waiting time. There were only 11 dedicated cancer geneticists across the 22 centres. Referrals were mainly concerned with breast (63%), bowel (18%) and ovarian (12%) cancers. Only 7% of referrals were for men and 3% were for individuals from ethnic minorities. Referral rates varied from 76 to 410 per million per annum across the regions. Median waiting time for an initial appointment was 19 weeks, ranging across regions from 4 to 53 weeks. Individuals at population-level genetic risk accounted for 27% of consultations (range 0%, 58%). Shortfalls in cancer genetics staff and in the provision of genetic testing and cancer surveillance have resulted in large regional variations in access to care. Initiatives to disseminate referral and management guidelines to cancer units and primary care should be adequately resourced so that clinical genetics teams can focus on the genetic testing and management of high-risk families. © 2001 Cancer Research Campaign http://www.bjcancer.co

    Protective role of vitamin B6 (PLP) against DNA damage in Drosophila models of type 2 diabetes

    Get PDF
    Growing evidence shows that improper intake of vitamin B6 increases cancer risk and several studies indicate that diabetic patients have a higher risk of developing tumors. We previously demonstrated that in Drosophila the deficiency of Pyridoxal 5' phosphate (PLP), the active form of vitamin B6, causes chromosome aberrations (CABs), one of cancer prerequisites, and increases hemolymph glucose content. Starting from these data we asked if it was possible to provide a link between the aforementioned studies. Thus, we tested the effect of low PLP levels on DNA integrity in diabetic cells. To this aim we generated two Drosophila models of type 2 diabetes, the first by impairing insulin signaling and the second by rearing flies in high sugar diet. We showed that glucose treatment induced CABs in diabetic individuals but not in controls. More interestingly, PLP deficiency caused high frequencies of CABs in both diabetic models demonstrating that hyperglycemia, combined to reduced PLP level, impairs DNA integrity. PLP-depleted diabetic cells accumulated Advanced Glycation End products (AGEs) that largely contribute to CABs as α-lipoic acid, an AGE inhibitor, rescued not only AGEs but also CABs. These data, extrapolated to humans, indicate that low PLP levels, impacting on DNA integrity, may be considered one of the possible links between diabetes and cancer

    Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis

    Get PDF
    Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy. Methods We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance. Results We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography. Conclusion Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data

    Complex organic matter in Titan's atmospheric aerosols from in situ pyrolysis and analysis

    Full text link
    Aerosols in Titan's atmosphere play an important role in determining its thermal structure(1-3). They also serve as sinks for organic vapours(4) and can act as condensation nuclei for the formation of clouds(5,6), where the condensation efficiency will depend on the chemical composition of the aerosols(5,7). So far, however, no direct information has been available on the chemical composition of these particles. Here we report an in situ chemical analysis of Titan's aerosols by pyrolysis at 600 degrees C. Ammonia (NH3) and hydrogen cyanide (HCN) have been identified as the main pyrolysis products. This clearly shows that the aerosol particles include a solid organic refractory core. NH3 and HCN are gaseous chemical fingerprints of the complex organics that constitute this core, and their presence demonstrates that carbon and nitrogen are in the aerosols.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/62786/1/nature04349.pd

    Cost-effectiveness of the SEN-concept: Specialized Emergency Nurses (SEN) treating ankle/foot injuries

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Emergency Departments (EDs) are confronted with progressive overcrowding. As a consequence, the workload for ED physicians increases and waiting times go up with the risk of unnecessary complications and patient dissatisfaction. To cope with these problems, Specialized Emergency Nurses (SENs), regular ED-nurses receiving a short, injury-specific course, were trained to assess and treat minor injuries according to a specific protocol.</p> <p>Methods</p> <p>An economic evaluation was conducted alongside a randomized controlled trial comparing House Officers (HOs) and SENs in their assessment of ankle and foot injuries. Cost prices were established for all parts of healthcare utilization involved. Total costs of health care utilization were computed per patient in both groups. Cost-effectiveness was investigated by comparing the difference in total cost between groups with the difference in sensitivity and specificity between groups in diagnosing fractures and severe sprains. Finally, cost-effectiveness ratios were calculated and presented on a cost-effectiveness plane.</p> <p>Results</p> <p>No significant differences were seen between treatment groups for any of the health care resources assessed. However, the waiting times for both first assessment by a treatment officer and time spent waiting between hearing the diagnosis and final treatment were significantly longer in the HO group. There was no statistically significant difference in costs between groups. The total costs were € 186 (SD € 623) for patients in the SEN group and € 153 (SD € 529) for patients in the HO group. The difference in total costs was € 33 (95% CI: – € 84 to € 155). The incremental cost-effectiveness ratio was € 27 for a reduction of one missed diagnosis and € 18 for a reduction of one false negative.</p> <p>Conclusion</p> <p>Considering the benefits of the SEN-concept in terms of decreased workload for the ED physicians, increased patient satisfaction and decreased waiting times, SENs appear to be a useful solution to the problem of ED crowding.</p
    • …
    corecore